This paper proposes a new metric called MID (Mask–Image Distributional Divergence) for evaluating medical image segmentation tasks. MID uses a pre-trained medical vision encoder to jointly encode images and the binary masks for each class, mapping them to a feature space, and then calculates the binary 2-Wasserstein distance between the reference set and the prediction set. Extensive validation across 13 public datasets (comprising a total of 56 organ groups) has demonstrated that it tracks corruption severity, detects distribution shifts, identifies image-mask misalignment, and ranks models consistently with paired metrics.
Strengths and weaknesses
Strengths
- Compared with metric evaluation methods that require ground truth (GT), the proposed method can be applied in scenarios where test set ground truth is unavailable, which is of particular practical value for medical images. Compared with existing evaluation methods that do not require ground truth, the proposed method does not need to train a model on each target dataset, but instead directly compares data distributions, making it scalable.
- The paper is well-written and well-organized, and the figures are clear.
- The proposed idea is simple and straightforward; as shown in Equation 2, the proposed MID borrows from the concept of FID and effectively extends it to the joint distribution space of graphs and masks.
- Section 3.4 is interesting; through image-mask shuffling experiments, it demonstrates that this metric is indeed capable of isolating the failure of ‘spatial correspondence’ on its own, rather than merely examining the shape of the mask.
- The appendix contains very detailed ablation experiments (such as those involving different backbones and sample size sensitivity analyses), and the code has already been provided.
Weaknesses
- When calculating the 2-Wasserstein distance, MID assumes that the projected feature space follows a normal distribution. In practice, when data from multiple organs, multiple centres or mixed modalities are aggregated into a unified Global Reference Pool, the feature distribution is often multimodal. There is a lack of discussion regarding this scenario.
- Appendix Table 6 shows that when the sample size n of the candidate set is less than 100, the Fréchet estimator exhibits a very pronounced positive bias in finite samples (with the mean MID rising sharply from 0.30 to 1.85). In the early stages of prospective clinical deployment, there may be only a very small number of cases, which limits the real-time application of MID in small-batch online monitoring.
Questions
- To what extent does the performance of MID deteriorate when multi-peaked clustering occurs in the reference pool? Can the use of a Gaussian mixture model (GMM) or non-parametric methods to estimate the Wasserstein distance alleviate this ‘domain coverage’ issue? Please provide experimental results for this scenario.
- Can MID be effectively applied to small-scale clinical data, or is its applicability limited to the evaluation of large datasets?
Limitations
yes
Paper formatting concerns
No concerns.
We thank the reviewer for the careful reading and constructive assessment. We address the two concerns below, which are associated with the AC's priorities on the single-Gaussian assumption and small-sample bias.
GMM and non-parametric alternatives (reviewer Q1/W1, AC priority 2). We agree that the global reference pool can be multi-modal, especially when CT and MRI, multiple anatomies, or multiple centres are pooled. To quantify whether this deteriorates MID's behaviour, we compared the default single-Gaussian MID with a two-component Gaussian-mixture variant on joint embeddings, scoring candidates with the mixture-Wasserstein upper bound of Delon–Desolneux [1]. Using the synthetic corruption setup in Appendix B, we constructed bimodal CT/MRI candidate distributions across 5 seeds and 7 severity levels. The rankings produced by the GMM and by the single-Gaussian default agree closely (mean Spearman ρ=0.99). This suggests that, in this setting, multi-peaked clustering does not materially deteriorate MID's ability to rank candidate distributions by degradation severity; its main effect is on absolute scale. We will clarify this in the Discussion: GMM variants are preferable when absolute-scale interpretability matters more than ranking, whereas the current single-Gaussian setup is appropriate when the goal is comparative ranking.
Regarding the non-parametric alternative, Appendix E already considers Kernel Inception Distance (KID) as a baseline. In the metric comparison (Table 4), KID tracks segmentation quality less well than MID (ρ=−0.28 for KID vs. −0.55 for MID against Dice), indicating that the added flexibility of a kernel estimator does not translate into a better quality signal, and that the parametric fit is preferable in this setting. Non-parametric optimal-transport estimators are an option in principle, but they are markedly more sample-hungry, which makes them less suitable for the small candidate sizes typical in this domain (Table 3).
[1] Delon, Julie, and Agnès Desolneux. "A Wasserstein-type distance in the space of Gaussian mixture models." SIAM Journal on Imaging Sciences 13.2 (2020): 936–970.
Small-scale clinical applicability and finite-sample bias (reviewer Q2/W2, AC priority 3). We agree that raw Fréchet estimates have finite-sample bias, and Table 6 quantifies this as candidate-set size varies. Building on it, our reference-size stability analysis indicates that n≥250 feature representations per group is sufficient for standalone use; for 50≤n<250, a finite-sample correction changes the main quality correlations by less than 0.03; and for n<50, standalone assessment is not reliable. These thresholds refer to feature representations rather than scans, so n≥250 can correspond to roughly 60 subjects when several anatomies are monitored.