- Rating
- 4
- Clarity
- 2
- Confidence
- 3
- Originality
- 2
- Quality
- 3
- Significance
- 2
Read review
Summary
This work addresses the central challenge of noisy pseudo-labels in semi-supervised medical image segmentation by combining parametric network predictions with non-parametric prototype-based predictions. The method uses confidence-aware selection, prototype entropy minimization, and KL-based dual-space alignment to exploit the complementary strengths of both spaces. The claims of the paper are supported by experiments on ACDC, Left Atrium, and Pancreas-NIH, showing improvements over prior methods.
Strengths and weaknesses
Strengths:
- The pseudo-label noise problem is reinterpreted from the perspective of parametric vs. non-parametric prediction space.
- Semi-supervised segmentation in both 2D and 3D is covered.
- Confidence-aware selection is reasonable. It does not force alignment of all pixels, but only performs complementary learning when at least one space is reliable.
Weaknesses:
- One point I am concerned about is the issue of innovation. As far as I know, prototype alignment is not a very new idea. For example, the following works all mention similar ideas [1-4]. I will refer to other reviewers' opinions on this point in the rebuttal.
- The authors used UNET/VNet as the backbone. I understand this is for fair comparison. However, some recent works have achieved better semi-supervised segmentation results using stronger backbones [5]. Please add a discussion and comparison.
- This paper uses a lot of hyperparameters and does not include ablation. I checked the appendix but could not find it. If I have missed it, please point it out. Otherwise, it should be added in the rebuttal.
- The author describes parametric prediction as "easily affected by noise" and prototype prediction as "more stable." This intuition is reasonable, but there is no rigorous theoretical proof. Of course, the experiment seems to reflect this point. I think the authors should be more rigorous in their expression. It would be better if there were theoretical analysis (but not mandatory).
Refs:
[1]Xu, H., Liu, L., Bian, Q., & Yang, Z. (2022). Semi-supervised semantic segmentation with prototype-based consistency regularization. Advances in neural information processing systems, 35, 26007-26020.
[2]Wang, Y., Xiao, B., Bi, X., Li, W., & Gao, X. (2024). Boundary-aware prototype in semi-supervised medical image segmentation. IEEE Transactions on Image Processing, 33, 5456-5467.
[3]Yuan, Y., Wang, X., Yang, X., & Heng, P. A. (2024). Effective semi-supervised medical image segmentation with probabilistic representations and prototype learning. IEEE Transactions on Medical Imaging, 44(3), 1181-1193.
[4]Zhang, H., Ma, P., Liu, J., Lian, J., & Ma, Y. (2025). Prototype-augmented mean teacher for robust semi-supervised medical image segmentation. Pattern Recognition, 166, 111722.
[5]Yang, S., Xing, Z., & Zhu, L. VQ-Seg: Vector-Quantized Token Perturbation for Semi-Supervised Medical Image Segmentation. In The Thirty-ninth Annual Conference on Neural Information Processing Systems.
Questions
The main concern lies in the originality of the prototype-based method itself. Furthermore, I suggest adding a discussion and comparison of the mentioned references. Based on the opinions of other reviewers, if a majority of reviewers do not consider the originality problematic, and the authors have provided corresponding discussion and comparison results of the new methods, I will consider raising the score.
Limitations
The authors briefly mention limitations in the checklist, but the discussion is not sufficiently explicit in the main paper.
Paper formatting concerns
N/A
Final justification
After considering the rebuttal and the discussion, I believe most of my main concerns have been adequately addressed. In particular, the authors clarified the distinction from prior prototype-based methods and added controlled experiments with homogeneous predictors, a stronger backbone, and hyperparameter sensitivity analyses, which substantially strengthen the empirical support. The remaining concern is mainly the limited methodological novelty, also noted by the AC and another reviewer. Overall, I believe the rebuttal resolves most technical concerns, while the novelty issue remains but is not severe enough to outweigh the strengths, so I raise my final rating to 4.
Meta-review
The submission addresses semi-supervised image segmentation using a combination of parametric network predictions with non-parametric prototype-based predictions. This is a sensible approach, though not one that is particularly novel. In particular, Reviewers 8Xit and ojW2 both raise extensive concerns about the relationship to previous work. These concerns need to be addressed in a rebuttal. An additional concern is about the size of the effect of the method, with reviewers pointing out that the improvements over strong baselines are small.