- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 2
- Quality
- 2
- Significance
- 2
Read review
Summary
This paper investigates the issue of training-signal imbalance in medical image segmentation. The authors posit that the root cause may be a structural misalignment between the supervision target and the actual segmentation objective. They decompose this misalignment into two mechanisms, gradient-mass dilution and inter-class supervision noise, and propose a method called Progressive Signal Calibration (PSC). Experimentally, the authors first compare standard four-class supervision with foreground-focused supervision using a private kidney pathology dataset; they then evaluate the performance of PSC relative to the backbone across 18 public histopathology datasets and introduce an activation gating rule based on warmup statistics.
Strengths and weaknesses
Strengths.
- On a private renal pathology dataset, simply ignoring the background in the loss function led to a noticeable improvement in foreground mIoU across multiple backbones. This phenomenon is noteworthy, given that many medical segmentation tasks involve large background areas and relatively small foreground structures.
- In addition to the private dataset, the authors report per-dataset results across 18 public histopathology datasets and assess statistical significance using paired bootstrap confidence intervals, making the experimental findings more compelling.
- The ablation studies are clearly presented; Tables 1 and 2 help distinguish between the gains attributable to FG3 itself and those resulting from the additional PSC components.
Weaknesses.
- FG3 ignores background loss and merges all foreground categories under binary supervision; these practices are no longer equivalent to the original multi-class segmentation task. The authors attribute the significant performance gains observed under binary supervision to "inter-class supervision noise," a claim that warrants a more cautious interpretation.
- Although the paper positions FG3 as a "general-purpose recipe," it lacks comparisons against more direct baselines for handling class imbalance. Without appropriate controls, it is difficult to determine whether the improvements stem from the redefinition of the supervision target or simply from better handling of class imbalance.
- Across 18 public datasets, PSC yields an average improvement of approximately +0.013 fg-mIoU, indicating that the magnitude of the gain is modest. Without comparisons against strong imbalance-aware or boundary-aware methods under the same binary supervision setting, it is hard to assess whether PSC significantly outperforms existing training techniques.
- The figures in the "Full PSC" row of Table 2 do not perfectly match those for "Ours FG3" in Table 1; the authors attribute this discrepancy to differences in random seeds and early stopping sweeps. Given that Table 2 is intended to demonstrate the independent contributions and additivity of the various components, the ablation results should be re-reported using a consistent seed, training schedule, and stopping criterion.
Questions
- Under the FG3 setting, does the calculation of fg-mIoU include pixels in the background region that are predicted as foreground in the union for the foreground category? Or are background regions ignored during evaluation? This distinction directly affects the interpretation of Table 1.
- It is currently difficult to distinguish whether the performance gains stem from "changing the supervision target" or from "better handling of class imbalance." Could the authors include imbalance baselines that preserve the original multi-class labels?
- The tasks corresponding to binary supervision and multi-class/FG-focused supervision in Table 3 are not identical. If the fine-grained subtypes themselves hold clinical significance, should the binary mode still be considered a performance improvement?
- There are significant discrepancies between the ablation figures in Table 2 and the matched-backbone figures in Table 1. Could the authors re-report the ablation results for each component using the same random seed, training schedule, and stopping criterion?
Limitations
A critical limitation has not been sufficiently emphasized: binary mode may sacrifice clinically useful subtype information, and the improvement in fg-mIoU alone is insufficient to justify it. The authors should more clearly articulate the scope of applicability for PSC. If subtype classification is an integral part of the clinical problem, then binary supervision might not merely be a form of calibration, but rather a fundamental alteration of the problem definition itself.
Paper formatting concerns
No paper formatting concerns.
Final justification
The additional experiments alleviate my main concerns. The unified-protocol results, matched imbalance baselines, external validations, and factorial analysis provide stronger evidence for both the FG3 effect and the additional contribution of the PSC modules. While the evaluation-protocol inconsistency and the relationship between FG3 and conventional imbalance handling still require careful revision, the new evidence strengthens the paper.
Thank you for focusing on the most decision-relevant controls: evaluation protocol, imbalance-preserving baselines, task-definition scope, and matched ablation provenance. Your comments led us to tighten both the experiments and the wording.
All intervals are 95% bootstrap. Private-dataset comparisons are per-image paired bootstrap over the 275 test images (
N = 1000); the external MRI replication is patient-level paired bootstrap over 50 patients (N = 1000).Under FG3, the discrimination-facing score is Protocol B: evaluation is restricted to ground-truth foreground pixels, matching the
ignore_indextraining mask. We agree that this must be stated explicitly, so the revision will name both conventions wherever a number is shown:Under the matched Protocol-B convention, the five-backbone supervision effect is
+3.85to+11.79, with all five intervals excluding zero. This is the correct interpretation of the FG3 numbers in Table 1: they are Protocol-B gains in foreground discrimination, not deployment-facing all-pixel gains by themselves. We will make that explicit in the revision instead of leaving it implicit.Your question also prompted three verifications of the evaluator itself, which we now report rather than assert:
91.46vs91.458on the private test set, and91.699under either protocol on ACDC. Only precision, and hence fg-mIoU, changes.+5.61, precision-1.19, net fg-mIoU+4.18. A pure move along a fixed precision–recall curve would leave IoU flat or lower; here IoU rises, so the curve itself moves. On ACDC the same decomposition is recall-driven with no precision cost (+4.773recall,+0.254precision), and we report both cases rather than generalizing from one.0.827to0.495, confirming that the label-mapping path is live rather than a silent identity.Yes. We ran matched multi-class-preserving loss controls on the private dataset. The labels, backbone, and split are fixed; only the loss is changed.
All loss variants use the vanilla-tuned schedule with no per-loss hyperparameter search, so they should be read as untuned-under-matched-protocol rather than as tuned upper bounds.
This table supports a narrower and more defensible interpretation than the original draft. The completed multi-class-preserving controls are heterogeneous: some improve Protocol B, but every one of them falls below the 4-class vanilla baseline under Protocol A, and the degradation is monotone in reweighting strength (
82.01for sqrt-inverse,80.95for the heuristic,79.68for inverse-frequency) — the signature of buying foreground discrimination with background rejection. The nnU-Net-standard CE + Dice combination reaches81.27under Protocol A, also below vanilla, so this is not an artifact of an unweighted Dice objective alone.By contrast, Full PSC reaches
86.63under Protocol A, which is+2.46above the 4-class vanilla arm and above every reweighted control under the deployment-facing convention. Against the matched single-stage 4-class PSC arm at84.90— the same checkpoint that appears at90.11under Protocol B in the factorial above — the paired gain is+1.74, CI[+1.03, +2.45]. We therefore do not claim that FG3 "beats all imbalance methods"; the claim is that the effect is not reducible to a trivial reweighting artifact, and that deployment-facing behavior must be checked separately under Protocol A.We agree that this requires more cautious wording. In the revision, binary mode will be presented as a scope-limited operating mode, not as a universal improvement. To separate label-space change from mechanism interpretation, we also ran a same-binary-scoring control on BCSS: the 4-class model's own predictions are merged with
{0 -> 0, 1..K -> 1}before scoring, so both arms sit in the same binary label space. The resulting gap (binary supervision minus merged multi-class+background) is+0.0185, with CI[-0.0123, +0.0524]. We report this completed null: it is not strong enough to treat raw binary-vs-multiclass gaps as standalone proof of the inter-class-noise mechanism.Accordingly, the revision will make three changes. First, where subtype distinctions are clinically important, binary mode will not be presented as the preferred setting. Second, the renal case will continue to use
Pi_FG3, notPi_bin, precisely because those subtype distinctions are clinically meaningful there. Third, when we discuss the noise mechanism, we will tie it to measured annotator disagreement on the renal dataset (DCT vs atrophic-PCT,kappa = 0.34) rather than to the size of a binary-vs-multiclass score gap alone. The supervision-target contribution itself remains anchored on the five-backbone FG3 comparison and the external MRI replication, both of which hold the number of foreground classes fixed and are therefore unaffected by this concern.We agree that the ablation should be re-reported under a unified protocol. The revision will use the same three-seed summary that is already in the current draft:
We will state the conclusion in a narrower way than before: Full PSC is above the matched base by more than the seed spread, and both metrics recover the same overall ordering — fg-Recall, whose seed spread is roughly two to three times tighter (
0.33–0.68vs0.76–1.84), reproduces it independently — while we avoid strong claims about fine separation among individual modules atn = 3. This batch also cross-checks the matched factorial from a different source of variance:+2.42here (training variance across seeds) against+2.56there (test-set sampling variance for a fixed pair of checkpoints).Your remaining weakness note — that the
+0.013average across 18 datasets is modest, and that stronger comparators are needed — deserves a direct answer as well.On the average:
+0.013(that is,+1.31points) is a mixture rather than a typical case. Split by the gate's out-of-fold LODO prediction, the six datasets predicted PSC-effective average+3.03points and the remaining twelve average+0.45, and together these reproduce the+1.31overall. We use the prediction rather than theepsilon-defined label for this split so that it is not circular. On the separate criterion of interval significance, six datasets have intervals excluding zero with gains from+1.00to+4.68points, and none of the 18 is significantly negative — these two groups of six are defined differently and are not the same set. The literal statement the suite supports is therefore: significant gains of one to nearly five points on a third of the panel, attenuation toward zero elsewhere, and no significant regression anywhere. The magnitude claim itself rests on the matched private comparisons and the external replication, not on the pooled average, and the revision rewrites the abstract so that+0.013carries the safety-and-generality claim it was meant to carry.On comparators: the completed comparator evidence is the matched loss-control table above, now including nnU-Net-standard CE + Dice. It answers the causal question in your review directly — the FG3 effect is not explained away by ordinary imbalance handling, only partially and non-uniformly reproduced by it. A tuned benchmark-wide external sweep would license a broader claim than we have earned, so the revision does not assert superiority over the wider imbalance-aware literature.
All experiments added in this revision directly address the four concerns raised in your review, and all critical textual revisions are guided by your comments. The paper has achieved substantial improvements through supplementary experimental results and more rigorous wording. We hope the newly added experiments fully resolve the reservations underlying your review score.