- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 2
- Quality
- 3
- Significance
- 2
Read review
Summary
The authors assessed the ability of the pathology foundation model to preserve similarity ranking across different slides and institutions and compared the ability with MLLM. They used several known pathology foundation models to extract embeddings and compared the euclidean distances between the reference tiles and two candidate tiles. For MLLM models, they are given a prompt and three different image tiles (reference, positive, and negative) to determine if MLLM can distinguish similar tissue types. Overall the MLLM is able to outperform foundation model for both cross-slides and cross-institutional datasets, showing the robustness of MLLM while the pathology foundation model is better at showing similarity within the same slide, showing that it is more likely that the foundation model is learning from the slide-specific features and not able to generalize more than the MLLM models.
Strengths and weaknesses
Quality
The authors show a great experimental set up which clearly demonstrates the strength and weaknesses of MLLM and pathology foundation models.
Clarity
The manuscript is generally well written and easy to follow. The three comparisons set up are explained clearly and comprehensible for the readers to understand the motivation behind it.
Certain implementation details can be further clarified. For instance, the authors mentioned that some MLLM responses were invalid, what causes those invalidations and if foundation models are able to get the correct similarity for those invalid responses.
Significance
The authors address the gap in understanding the failure mode of the current pathology foundation models. It is essential to have a better understanding of how the pathology foundation model differs from MLLM in feature space.
The evaluation only compares the similarity ranking of the two models and no downstream clinical task was compared. While the authors are proving that the foundation model is learning from slide-specific features, they have not shown if the learned features in the MLLM can be used for downstream tasks.
Originality One of the main contributions of the paper is the comparisons set up. Given that the triplet comparison (reference/postive/negative) is a long-standing staple for metric learning, the originality lies in the three configurations of within-slide, cross-slide and cross-institution.
Questions
-
Q1. Were the embeddings L2-normalized before computing Euclidean distance? And is the comparative result robust to using cosine similarity / normalized embeddings?
-
Q2. What were some of the failure responses from the MLLM? Was the MLLM itself able to mention what causes the failure? How do you quantify a “valid” and “invalid” response from the MLLM? Would scoring invalid responses as incorrect, rather than excluding them, change the model rankings?
-
Q3. Does winning the triplet test predict winning clinical downstream tasks? Is it possible that the learned features from the foundation model are better at downstream tasks than the MLLM?
Limitations
No. The leap from similarity-ranking to downstream clinical utility is untested and unflagged, and the cross-institution evidence rests on few institutions. The authors have stated future work with other modalities which is reasonable but arguably less pressing than validating that the ranking advantage actually yields better task performance.
Paper formatting concerns
N/A
Final justification
This work shows that multimodal LLMs outperform specialized pathology foundation models in cross-institute/domain settings and presents a new benchmark. The results are insightful and most of my questions are addressed. I increased the score to 4 rather than 5 since the evaluation is limited to pathology images only.
We thank the reviewer for recognizing the quality of our experimental design and the significance of the research gap that our work addresses. Below is our point-by-point response to the reviewer's constructive feedback.
This rebuttal addresses the following meta review comment:
[hiNY.1] Originality of the similarity ranking setup.
Thank you for the thoughtful assessment. We agree the similarity ranking has been used in other machine learning scenarios. Our original contribution lies in the following aspects:
[hiNY.2] No downstream clinical task was compared. (Meta.1)
Thank you for pointing this out. We added a downstream task of confounded classification by following the experiment design from [4]. In these datasets the tissue classes are unevenly distributed across institutions, and the class-institution correlation is reversed between the training and test sets, so a model that exploits this shortcut is misled at test time. We evaluated 100 queries per dataset on the multi-institution datsets (CAMELYON16, TCGA, BEETLE). We found that this task's performance is predictable by the proposed similarity ranking at Pearson r=0.88 (p<1e-12). This task is deployment-relevant and safety-critical in clinical settings, because in real cohorts a diagnosis often correlates with the collecting site, and a model that exploits site-specific shortcuts can look accurate while failing to generalize, which is an effect that has been shown to inflate reported accuracy and bias predictions across medical centers [1,2,3]. As the table below shows, the best LLM exceeds or matches both the best pathology FM and the best general encoder on every dataset. Full results will be added to the camera-ready paper.
[hiNY.3] Whether MLLM features transfer downstream, and whether FM features could be better. (Meta.1)
Thank you for the question. In our benchmark, unlike the embedding models, the MLLMs do not output a numeric feature vector per tile. Instead they provide a ranking of similarity between tile pairs. Many downstream tasks such as classification can be solved directly from these pairwise rankings. As shown by the downstream classification task above, the similarity rankings generated by LLMs are more robust than the embedding distances of pathology FMs. The one regime where FM features remain the best choice is within a single slide or institution, which limits the generalization of the FM features.
[hiNY.4] (Q1) L2-normalization and cosine robustness.
Thank you for the question. We used raw unnormalized pooled features with Euclidean distance. Re-scoring every embedding model with cosine similarity, which equals L2 on L2-normalized features, on all six datasets changes overall accuracy by a mean absolute difference of at most 0.015. On every dataset the best pathology FM under cosine stays below the best LLM, so no conclusion changes. We will add these ablations to the camera-ready paper.
[hiNY.5] (Q2) Causes of invalid MLLM responses and whether the model explains them.
Thank you for the question. Upon further investigation, we found that most invalid responses come from reasoning models that were not allocated a sufficient reasoning budget, which caused the LLM output to be truncated. We have fixed this issue by allocating a larger reasoning budget.
[hiNY.6] (Q2) How valid and invalid responses are quantified.
Thank you for the question. A response is valid when the parser recovers exactly one of the offered candidates in the LLM's output JSON. The valid-response rate is at least 99% for the top LLMs on every dataset. Open-weight models hosted by third-party providers have lower valid-response rates (usually around 90%).
[hiNY.7] (Q2) Would scoring invalid responses as incorrect change the rankings.
Thank you for the question. Re-scoring invalids as incorrect rather than excluding them never changes the best-LLM-per-dataset winner, because the top models are near 100% valid. It only reorders the open-weight LLMs within all LLMs.
[hiNY.8] Whether pathology FMs handle the comparisons where the MLLM was invalid.
Thank you for the question. On the comparisons where an LLM was invalid, the best pathology FM scores only 0.47 to 0.67, close to its overall accuracy on the same datasets, so those comparisons are not systematically easy for the FMs.
References
[1] Howard et al. The impact of site-specific digital histology signatures on deep learning model accuracy and bias. Nat. Commun., 2021.
[2] de Jong, Marcus, Teuwen. Current Pathology Foundation Models Are Unrobust to Medical Center Differences. 2025.
[3] Dehkharghanian et al. Biased Data, Biased AI: Deep Networks Predict the Acquisition Site of TCGA Images. Diagn. Pathol., 2023.
[4] Kömen et al. Do Histopathological Foundation Models Eliminate Batch Effects? A Comparative Study. 2024.
[8] Filiot et al. Distilling Foundation Models for Robust and Efficient Models in Digital Pathology. MICCAI, 2025.
[10] Kapse et al. GenBio-PathFM: A State-of-the-Art Foundation Model for Histopathology. bioRxiv, 2026.