- Rating
- 4
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The authors proposes a large-scale generative model for generating chest X-ray images. The authors build CXR7-1M (a large chest dataset combined from 7 different datasets). They train a large rectified-flow transformer as the generative model, which has 1.3B-parameters. The model supports controlled generating of images (i.e. patient metadata, imaging view, or clinical findings). The authors also studies VAE design for chest X-ray reconstruction quality, and uses Rad-DINO features as a specific perceptual signal. The paper evaluates the model using distributional generation metrics, VAE reconstruction metrics, subgroup editing metrics, and a small clinical experts team to distinguish real images from synthetic ones.
Strengths and weaknesses
Strengths:
This work studies controllable chest X-ray image synthesis, which is a relevant and useful topic that sort of handling the difficulties in medical imaging (i.e. collect, share, clinical labels, etc.), as it could be useful for data augmentation, testing, etc.
Has a large combined preprocessed dataset. The authors combine 7 CXR datasets and merged them into a dataset with useful metadata metadata. This could potentially be a good merged dataset if this dataset is made available to the community, considering the alignment of various dataset are usually long and tedious.
They have a 1.3B-parameter rectified-flow transformer model, with details on how the transformer is trained, tested, and evaluated. They also have discussion on expert evaluation, which is good. The experiments reports multiple metrics, and the reports are generally well-organized, specifically, I like table 3. The paper also studies VAE reconstruction quality.
The expert study is useful, albeit a bit small. The paper is generally clear and the main pipeline is understandable.
Weaknesses:
There is an important concern about reproducibility: the paper’s main contribution depends heavily on the processed dataset, source code and the trained model, but they do not appear to be available at submission time. This makes the main claims harder to verify. I would consider raise my score if the authors can provide a concrete and verifiable access path, even if only for inference and evaluation.
The method novelty need better clarifications. Many components (e.g. rectified flow, transformer, VAE, etc.) are existing ideas. The contribution seems to be mainly the scaling and integration of these components, it is useful, but more clarification on what is technically new would be more interesting.
The comparison to prior models is not fully apple-apple. The proposed model is trained on a larger and more diverse dataset than many baselines. Therefore, it is hard to precisely know if the improvement comes from the model design or larger dataset. Strong baselines trained on the same CXR7-1M dataset, would make the result stronger support the claim.
The clinical validation is a little bit limited. The real-vs-synthetic test use 3 experts and a relatively small number of images. Besides, being hard to distinguish from real images does not necessarily show that generated iamges have clinical information. More expert evaluation on clinical correctness, if possible, would strengthen the claims.
The dataset construction could introduce noise and bias. Since the model is trained and conditioned on on these data, label quality is important, it would be good if more analysis of label noise, missing labels, and subgroup imbalance could be conducted.
Finally, the paper mainly shows improved synthesis fidelity. It would be good if the paper can show whether the synthetic data improves downstream clinical model performance.
Questions
Can the authors provide concrete release details for code, checkpoints, scripts, etc., or at least a viable verifiable path? Since the main contribution depends on these resources.
Can the authors provide a comparison that the baselines are trained or fine-tuned on the same CXR7-1M data for a better evaluation?
Can the authors provide more clinical validation of generated images? (i.e. whether edited pathologies are correct)
How robust are the model to label noise and missing labels? Harmonized data from multiple sources could have higher such noises, an ablation could help better understand the model's capabilities.
Can the authors clarify which parts of the method are intended as algorithmic contributions versus domain-specific scaling and engineering?
Limitations
Partially. The authors discuss some limitations such as label coverage. But it would be good if the author could also discuss about label noise, potential imbalance, risk that images are visually realistic but clinically incorrect, etc. as discussed in previous section.
Paper formatting concerns
No.
Final justification
The authors addressed most of my main concerns, so I raise my score from 3 to 4.
The new comparison experiments make it more fair and show that the improvement is not only from using more data. The new downstream experiments provide better evidence that the images can be useful. The authors also state that they've provided code and checkpoints to the AC.
Some concerns remain, especially the public release of the resources. But considering the previous efforts, I will raise to 4.
We thank the reviewer for recognising our work as “relevant and useful”, the value of our clinically harmonised dataset to the community, and the detailed development and evaluation of our 1.3B-parameter model. We also appreciate their positive assessment of the clinical expert study and the paper’s overall organisation and clarity.
As suggested, we have now run additional experiments including training our own model on the CheXGenBench training set used for the baselines, and training the best baseline on our large CXR7-1M training set, to allow a direct apples-to-apples comparison. In both cases, the fidelity of images generated by our model outperforms the baselines. Additionally, we now evaluate the downstream utility through a series of new experiments, including debiasing of training data, use of synthetic images for data augmentation, and stress testing the counterfactual robustness of disease detection models. The additional results demonstrate the benefits of using synthetic images for downstream tasks.
We address all of the reviewer’s comments and provide further clarifications below.
As per the NeurIPS guidelines, we have provided the AC with a private link to the code, model checkpoints, and a lightweight Python package/Jupyter notebook for model inference using RadiT XL (1.3B). The official release will include further reproduction instructions as well as full public access and licensing details, all of which are still being finalised. Since the proposed CXR7-1M dataset is derived from other public datasets, its release will remain subject to the licenses and conditions of the original sources which are all openly available for research. Our own code will be released under permissive licenses to facilitate future work and downstream applications. We would like to note that it was always our intention to release the code, but it was not yet in a polished state at the time of submission.
To address this point, we have now conducted new sets of controlled experiments. The first isolates RadiT B from the CXR7-1M dataset, by training it from scratch on the same MIMIC-CXR split used by the CheXGenBench baselines. The exact same training setup/hyperparameters as the original RadiT B training run on CXR7-1M was used. We ran the evaluation on the CheXGenBench 5K test split from MIMIC. Despite having half the trainable parameters, RadiT B (0.3B) achieves an FDD of 40.10 compared to 54.23 by CheXGenBench-Sana (0.6B), which we reproduced independently at 48.65 using identical evaluation pipelines. These results demonstrate the merits of our training approach separately from the dataset scale.
Additionally, we retrain the strongest baseline from CheXGenBench using CXR7-1M (i.e. Sana, using the official codebase and an identical training setup to CheXGenBench). Specifically, we use Sana with the official code implementation and the same training hyperparameter configuration described in CheXGenBench. Since CXR7-1M does not include text reports by default, we implemented a simple metadata-to-prompt conversion strategy that concatenates all metadata keys and values into a text prompt we can use for training. The following is an example prompt:
Dataset: MIC; Race: White; Sex: Male; Age: 77; View: LATERAL; Atelectasis: Missing; Cardiomegaly: Missing; Consolidation: Missing; Edema: Negative; Enlarged Cardiomediastinum: Positive; Fracture: Missing; Lung Lesion: Missing; Lung Opacity: Missing; No Finding: Missing; Pleural Effusion: Negative; Pleural Other: Missing; Pneumonia: Missing; Pneumothorax: Negative; Support Devices: MissingOur Sana model was fine-tuned on 4.75M CXR7-1M image-text pairs, mirroring CheXGenBench’s Sana training/hyperparameter setup on their MIMIC split. As reported in the table below, our Sana fine-tuned on CXR7-1M achieves an FDD of 37.38 compared to 54.23 achieved by CheXGenBench’s Sana fine-tuned on their MIMIC split (reproduced at 48.65). This is a modest FDD improvement in comparison to our flagship model, RadiT XL, which reaches 13.152 FDD.
We hope to have additional clinical evaluations in the coming days. We are in the process of conducting further validation with our expert collaborators, although this requires working around their busy clinical schedules in the short response/discussion time frame.
Our methodology is designed to compensate for missing labels during both training and inference (we use the null token trick from [1] to handle missing metadata, such that we condition only on known labels), which is beneficial when curating a large dataset from multiple sources. While we made every effort to appropriately harmonize the labels from each source comprising CXR7-1M with clinician-in-the-loop, we acknowledge that, as with any dataset compiled from multiple sources, label noise may have an impact on the resulting models. We agree that this is an important potential limitation, and something that we are actively investigating in follow-up work.
[1] Ho, Jonathan, and Tim Salimans. "Classifier-free diffusion guidance." arXiv preprint arXiv:2207.12598 (2022).
We view the overall foundation model recipe as the primary contribution of this work. It provides a systematic framework for incorporating domain knowledge throughout generative model development, including clinician-guided harmonisation of pre-training data (Section 3), clinician-derived causal modelling, domain-specific VAE perceptual optimisation, and systematic evaluation and ablation of architectural choices (Section 4). Although developed for chest radiography, this recipe provides a transferable blueprint for developing foundation models in other areas of healthcare imaging and beyond. Additionally, we now also provide strong evidence for the clinical utility of medical imaging generative models. Debiasing of data, enhancing training sets, and stress testing of off-the-shelf disease detection models are relevant in many clinical application domains.
From a technical perspective, our continuous-time flow SCM formulation (Section 4.3) also constitutes a novel algorithmic contribution. Specifically, it unlocks scalable, exact abduction for discrete variables in deep SCMs, a capability not provided by prior approaches (Pawlowski et al. 2020; Ribeiro et al. 2023, 2025). We will make this distinction clearer in the final version. Further technical details are provided in Appendix B.3.