- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The work shows how tokenizers affect latent medical image generation. The authors argue that tokenizers influence downstream generative performance. Notably, the authors use a controlled factorial design on ChestMNIST to compare various discrete (VQ, LFQ, FSQ) and continuous (VAE/AE) tokenizers across different vocabulary sizes, generators, and sampling budgets (keeping other factors constant). They present a rate–distortion–modelability perspective, showing that reconstruction quality alone is not sufficient for selecting a tokenizer. The experiments show that the choice of tokenizer is a key factor in generation quality. LFQ stands out as the strongest default discrete tokenizer, and the tokenizers that provide the best reconstructions do not always produce the best generated images.
Strengths and weaknesses
Strengths:
- The paper addresses an overlooked aspect of latent generative modeling by properly studying the impact of tokenizer choice on downstream generation quality.
- The experimental design is very elaborate. For example, it contains matched encoder-decoder architectures, latent grid sizes, vocabulary sizes, and evaluation protocols.
- The study factorizes the effects of tokenizer family, generator family, vocabulary size, and sampler budget as a result reader gets empirical insights of the work.
- The evaluation setup is well chosen, for example, bootstrap confidence intervals, domain-feature validation, cross-dataset replication, and memorization analysis.
Weaknesses:
- The study is limited to relatively low-resolution benchmark datasets. This makes it unclear whether the conclusions generalize to higher resolution. Also, the performance under clinically realistic medical imaging settings is needed to be explored.
- This question may be out of scope for the current work; however, it is still worth exploring the theoretical understanding behind why certain tokenizers, such as LFQ, lead to more modelable latent spaces.
- The authors defined modelability through downstream generation metrics (primarily FID). The paper does not provide a direct measure or analysis of latent-space complexity.
- The practical implications for downstream medical applications are not explored; it is not very clear whether the observed tokenizer preferences translate to improvements in tasks such as diagnosis, segmentation, or data augmentation.
Questions
- The study is performed on relatively low resolution benchmark datasets. Do the authors expect the same tokenizer rankings to hold for higher resolution medical images? Some results on this would help understand how broadly the conclusions may apply.
- Readers may get curious about why LFQ appears to produce more modelable latent spaces than the other tokenizers. Some qualitative intuition could help explain this behavior.
- Modelability is measured through downstream generation quality. Are there any latent-space statistics that seem to correlate with modelability?
- Some discussion on this limitation would be useful. How dependent are the conclusions on the particular generators and samplers used in the study?
- It would be interesting to know whether the tokenizer rankings are also reflected in classification, segmentation, or data augmentation. This would strengthen the practical relevance of the work.
Limitations
Yes. Check questions and weaknesses sections for missing critical points from the submitted manuscript.
Paper formatting concerns
N/A
Final justification
A lot (but not all) of my concerns have been addressed. I am upgrading my score to Borderline Accept.
Thank you for the careful reading and constructive comments. We used the discussion period to run additional analyses addressing the main points in the review. Unless stated otherwise, the results below were obtained after submission.
For the questions about modelability, we tested whether a generator-free statistic of the token field is associated with downstream generation quality. For each discrete tokenizer, we measured marginal entropy, variation in entropy across spatial positions, and neighbour-conditional predictive gain. The last quantity measures how much knowing the token immediately to the left or above reduces uncertainty about the current token. Bigram counts are fitted on the training split and evaluated using held-out cross-entropy on the test split, so a sparse table that memorises the training data is penalised. The smoothing parameter is selected on validation data without using FID.
Using rank-AUC to separate the three VQ tokenizers from the six LFQ and FSQ tokenizers gives:
The predictive-gain result is the same for left and upper neighbours using validation-selected smoothing.
Marginal entropy does not support the explanation given in the submission. VQ lies between LFQ and FSQ on that measure, so marginal entropy alone separates the families no better than chance. Neighbour-conditional predictive gain does separate them in this analysis.
The result is consistent with local dependence being more relevant than marginal entropy alone. LFQ produces high-entropy tokens with relatively weak dependence on neighbouring positions, while VQ's learned codebook produces stronger spatial structure. Different generators may handle this structure differently, which would be consistent with the quantizer–generator interaction in the paper. This is an interpretation of the result, not something established by the current sample.
There are only nine tokenizers in this analysis, so we will treat it as a small-sample, family-level result and will not report p-values. We also do not consider the exact ordering within each family reliable, since some FID differences are around 0.04, smaller than the seed variation measured elsewhere. The claim supported by the current analysis is that neighbour-conditional predictive gain separates the broad tokenizer families better than reconstruction PSNR or marginal entropy.
We could not run the requested higher-resolution experiment during the discussion period. We do not have tokenized data at 128 or 224 pixels, and retokenizing and retraining at four times the token count was not feasible in the available window. We will limit the claims to low-resolution medical-style images.
We did test whether training-set size explains the change in tokenizer ranking between ChestMNIST and PneumoniaMNIST. When ChestMNIST is subsampled to 4,700 examples, LFQ+AR still outperforms VQ+AR, with FID-192 of 0.946 versus 2.023. The cross-dataset result is therefore not explained by sample count alone. A matched non-medical replication and a higher-resolution experiment remain important follow-up work.
The dependence on the chosen generators and samplers is part of the result. The factorial analysis shows that generator rankings change across tokenizer families, with the quantizer–generator interaction accounting for 18.8% of the observed variation. Sampler selection can also change the apparent generator ranking.
The conclusion is therefore conditional on the generators and samplers tested. This means that the components cannot be selected independently; it does not mean that the current experiment establishes the same interaction for every possible generator. We checked whether the interaction survives training variation by retraining the vocabulary-1024 block at three seeds. Six of the nine pairwise quantizer comparisons are larger than three times the pooled standard deviation, including the comparisons that establish the interaction.
For the downstream classification and augmentation question, the current generators are unconditional and do not produce images with pathology labels. A direct synth-then-classify experiment would therefore require labels to be assigned after generation, making the result difficult to interpret.
We instead ran a classifier two-sample test in which a discriminator distinguishes real from generated images. Across 12 cells and three seeds, its ranking agrees with FID-192 at Spearman 0.78. The test does not use Inception features or a Gaussian approximation and is consistent with the domain-feature FID agreement of 0.943 already reported in the paper.
The best model, AE+RF, gives discriminator AUC 0.55, so the classifier is only slightly better than chance at separating its samples from real images. Poor models give AUC values close to 1.0, in line with their FID results.
This is not a test of clinical utility. A direct utility study would require pathology-conditional generation followed by training or augmenting a classifier with synthetic images carrying valid labels. We will state this as future work rather than presenting the two-sample test as an answer to the clinical utility question.
The predictive-gain analysis does not settle the broader question of modelability, but it provides a generator-free statistic that is associated with the tokenizer-family differences observed in this study.