- Rating
- 3
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 2
- Significance
- 2
Read review
Summary
The paper proposes ORA, a pretraining objective that, per medical code, jointly models the discretised time-to-next-occurrence and its value, with a censoring term. It is evaluated across classification, time-to-event, and lab-value regression, across two datasets and two backbones (Transformer, Mamba), and includes a fixed-tokeniser/backbone ablation. I appreciate the breadth and the clean ablation design, but I have concerns about whether fair and reproducible comparisons support the main claims.
Strengths and weaknesses
S1. EHR modelling, especially in the foundation model setting, for time-to-events is novel and timely, and I appreciate the authors' contribution. It is well-motivated.
S2. The ablation is well-designed and cleanly separates the methodological contribution.
I have reviewed the provided code, and the weaknesses below are partly informed by the implementation.
W1. The tabular baselines (classification, TTE) are built from code counts only, as far as I can see, and the featuriser discards all numeric lab values and vital signs, whereas ORA and foundation models use those values through the tokeniser. Thus, the gap to XGBoost is large on lab-driven tasks (mortality, LOS) and smaller on utilisation/onset tasks. This is an unfair empirical setup.
W2. The code trains LightGBM (not XGBoost), tunes it with just 10 trials, and uses a zero-hidden-layer linear network for the DeepHit baseline. Please clarify which one you used and provide a more fairly-tuned baseline. The near-random numbers (around 0.55 C-index) suggest an underpowered baseline and not necessarily a large ORA advantage.
W3. In MIMIC-IV, ICD diagnoses are per-admission billing codes with no independent onset date, so "time to first diagnosis" is the interval to the next admission where the code is recorded, and for outpatient-diagnosed chronic conditions (Celiac, MASLD), this is whether/when the patient returns to admission. Combined with last-contact censoring (subjects censored before the horizon are dropped), the IPCW C-index assumption of independent censoring is likely violated.
W4. The compute item under the checklist answers "Yes" citing "hardware type and compute information," but no GPU type, memory, or runtime appears in the main text that I could see, and the significance item claims 95% CIs on ORA–baseline differences with p=0.05 markers, but the tables show only an undefined per-cell std with no significance testing.
W5. The Fig. 2 TTE baseline (0.545) does not match the appendix DeepHit average (0.595), and the task-specific baseline should not be different between the Transformer and Mamba panels? Also, the released regression-baseline code targets different labs than the reported tasks. The last-value regression baseline beats all models on Creatinine/Platelets (R^2=0.88/0.91), averaging R^2 across tasks kind of hides this.
W6. I am worried that the contribution of ORA over SurvEHR/ICareFM is modelling time and value jointly rather than factorised, which is reasonable but incremental. The "full joint likelihood" / "one loss to rule them all" might be overstating this, since the objective assumes conditional independence across codes.
W7. ICareFM has no usable implementation out yet, and SurvivEHR provides the architecture but no weights as far as I am aware. Also, SurvivEHR was trained on primary care data. Are the reported results in your work your own reconstructions? Yet the released code supports only motor/tpp/mtpp/mtpp_shared/ntp and has no ICareFM or SurvivEHR loss that I could find in your provided code.
Questions
- With more fairly set-up baselines, does ORA still beat task-specific models on classification and TTE?
- Why is the baseline reported/cited as XGBoost when LightGBM is used?
- Per-task censoring rates and incident-vs-carried-forward fractions for the TTE tasks and justification for IPCW C-index under last-contact censoring.
- Fix the Fig. 2 vs Table 7 baseline and the regression baseline code/targets.
- Correct or substantiate the compute and significance checklist answers.
- Are concurrent events excluded from supervision?
- Respond to the foundation model implementation code weakness above.
Limitations
See above.
Paper formatting concerns
The provided zip of code still has your guidance documents for the coding agent you were using.
Final justification
Issues regarding code reproducibility, metric inclusion, and improved tuning results led to my increasing my score. However, I remain insufficiently convinced by the variety of baselines and datasets included, and the rigour of the contribution.
Meta-review
This paper proposes a new training objective for EHR Foundation model that jointly models event prediction with the TTE for next event prediction. The motivation to propose an objective that takes into account the nature of the structured EHR records is very valuable. However, there are exist many work in this area that propose architectures and objectives that are designed to augment next token prediction with TTE. Some of these work are highlighted by the reviewers but similar approaches can also be found in medical foundation models (example: https://www.nature.com/articles/s41586-025-09529-3 ). The work needs to better acknowledge the existing work, highlight how the approach is different and what specific shortcomings it overcomes, or even include a comparison.
Also, regarding comparison and benchmarking, In EHR foundation model, design choices like how binning is done, how time is discretized, .... have a big impact on the performance, and many of the existing EHR foundation models have different strategies when in comes to this. Authors first need to clarify the design choices made for their method (as raised by reviewers as well), and then discuss how these choices impact the evaluation and comparison. Finally, Reviewer Un7j has raised a number of concerns regarding the code-base that require clarification during the rebuttal.