- Rating
- 2
- Clarity
- 2
- Confidence
- 3
- Originality
- 2
- Quality
- 3
- Significance
- 2
Read review
Summary
This paper proposes ADAPCLA, a curriculum-style logit adjustment framework for generating long-tailed longitudinal EHR data. The method adds a frequency-derived correction term to the logits early in training to strengthen learning signals for rare codes, and gradually anneals this correction so that inference can be performed without external adjustment. The paper also introduces a delta-bias term for zero-shot cross-population adaptation without retraining.
Strengths and weaknesses
[Strengths]
- The paper addresses an important clinical problem, the underrepresentation of rare diseases in synthetic EHR generation.
- The curriculum design is intuitive, because the model is helped by a correction term early in training and later learns to operate without it.
- The negative control experiment in Table 3(a) is convincing and clearly shows why annealing is needed.
- The method outperforms existing methods throughout experiments.
[Weaknesses]
- The baselines seem somewhat weak, especially because EVA and SynTEG achieve almost zero PairSeen performance on MIMIC-III. The paper would be stronger with comparisons to generative models designed for underrepresented or long-tailed sample generation.
- The zero-shot adaptation component is not sufficiently isolated. Delta-bias looks close to a classical prior-shift correction, and Table 3(b) does not compare and . Because of this, it is hard to tell whether the target-population gains come from the delta-bias correction or from the backbone model.
- The evaluation also lacks privacy analysis, which is important for synthetic EHR generation.
Questions
- Theorem A.2 discusses internalization error, but I could not find a direct empirical measurement of it. Is there a way to estimate or approximate this quantity experimentally?
- For the zero-shot cross-population setting, could the authors show the delta-bias results with and ? It is hard to tell whether the improvement actually comes from the delta-bias correction itself or simply from the underlying backbone model.
- Could the authors provide clearer definitions and references for clinical plausibility metrics? I could not find how they are calculated.
- Since this paper focuses on synthetic EHR generation, have the authors checked privacy-related risks such as memorization, membership inference, or re-identification? This seems especially important for rare EHR patterns, since modeling them more faithfully could also make privacy leakage more likely.
Limitations
No. The paper does not sufficiently discuss several important limitations, including the insufficient isolation of the zero-shot delta-bias component and the weakness of some baseline comparisons. It would also be helpful to discuss privacy risks in synthetic EHR generation, especially memorization or re-identification risks for rare EHR patterns.
Paper formatting concerns
None.
Final justification
Thank you for the response. Q3 and W2 are addressed. However, the Q1 proxy is referenced to the final checkpoint and the three schedules are nearly indistinguishable, so the annealing speed effect in Theorem A.2 remains unverified. The privacy results also partly confirm rather than resolve my concern, since AdaPCLA shows the highest attribute-inference and near-duplicate risk among the compared methods. I keep my original score.
Thank you for your careful review. We have carefully considered your comments and conducted additional experiments. We hope that the new results and additional details below address your concerns, and we will incorporate them into the final version of the paper.
Q1. The theorem compares the model to an ideal population-level target that we cannot observe directly, so the exact theorem error cannot be measured from finite experiments. As an empirical proxy on 100 fixed MIMIC-IV contexts, we measured Eg(t)=Ex∥[zt(x)+αtbstat−zT(x)]g∥2/∣g∣, where the final checkpoint zT is used as the reference.
This shows that the intermediate logits become numerically close to the final logits after the training bias is removed. It is supporting mechanism evidence, not a proof of the theorem.
Q2. We report the full sensitivity grid for λ=[0,.25,.5,.75,1]. The metric is held-out AUPRC; λ is selected on the adaptation split by matching generated code frequencies to target code frequencies, not by using target test labels.
Thus even at λ=0 (no delta-bias), AdaPCLA exceeds HALO with selected Δb in both directions.
Q3. We will add exact formulas and cite the relevant evaluation traditions: medGAN (Choi et al., 2017, "Generating Multi-label Discrete Patient Records") for discrete patient-record distributional checks; RCGAN (Esteban et al., 2017, "Real-valued (Medical) Time Series Generation") for Train-on-Synthetic-Test-on-Real (TSTR) utility evaluation; HALO (Theodorou et al., 2023, "Synthesize Extremely High-dimensional Longitudinal EHRs") for longitudinal EHR generation evaluation; and EHR-Safe (Yoon et al., 2023, "High-fidelity and Privacy-preserving Synthetic EHRs") for fidelity/privacy assessment. Our tail-plausibility metrics instantiate these common ideas using support, Jensen-Shannon divergence, and Jaccard overlap, but the tail-focused metrics themselves are task-specific definitions introduced by our evaluator; we will not present them as copied named metrics from prior work.
Let R be the real training visits, S the generated visits, C(v) the deduplicated code set of visit v, and T the tail-code set computed from the training split only. Let PD be all unordered intra-visit code-pair occurrences from dataset D, and supp(PR) be the real pair support.
TSTR is reported separately as downstream utility, following the Train-on-Synthetic-Test-on-Real protocol used in RCGAN-style medical time-series evaluation. N/A means the denominator or valid tail context is absent, so the metric is undefined; it is not a numerical zero.
Q4/W3. Yes, we checked privacy-related risks including membership inference attack (MIA), exact/near duplicate risk, and attribute inference attack (AIA). These checks are motivated by standard privacy attacks and synthetic-data audits: membership inference attack follows Shokri et al. (2017, "Membership Inference Attacks Against Machine Learning Models"), attribute inference follows Fredrikson et al. (2015, "Model Inversion Attacks"), and duplicate/nearest-neighbor checks are commonly used in synthetic EHR fidelity/privacy assessment such as EHR-Safe (Yoon et al., 2023). These tests are not differential privacy guarantees; they measure possible memorization or attribute-disclosure risk in generated data.
Duplicate rates use patient-level Jaccard distance over code sets, threshold 0.05, and 3,000 queries. AdaPCLA has MIA AUC close to random guessing and fewer near duplicates than HiSGT, suggesting no obvious increase in memorization under these diagnostics; its higher AIA recovery indicates a possible attribute-disclosure trade-off. We will report these as empirical diagnostics, not as proof that AdaPCLA removes privacy risk.
W1. We agree that EVA and SynTEG are weak on MIMIC-III PairSeen and that stronger recent baselines are needed. We added HiSGT, MTGAN, and EHRDiff-Visit as supplementary reproduced baselines where their output format is compatible with our evaluator. The submitted mean$\pm$std table remains the official result. The table below is a single saved-sample snapshot with training-derived tail codes and K=20:
MTGAN is relevant to underrepresented multi-label time-series generation. HiSGT is a recent longitudinal EHR generator. EHRDiff-Visit is included only for visit-level metrics because it generates one binary admission/record vector, not an ordered patient trajectory. Thus SeqBigram and patient-level TSTR are N/A. MTGAN TSTR is also N/A because its converted output files do not preserve the exact code mapping needed to assign our same 25 disease labels.
W2. We agree that Table 3(b) did not isolate whether the zero-shot result came from the backbone or from Δb. We therefore evaluated HALO and AdaPCLA with and without Δb in both transfer directions. We frame this as temporal adaptation across MIMIC versions, not as multi-center transfer: MIMIC-III mainly covers 2001-2012, MIMIC-IV includes later admissions, and the later diagnosis-code cohort can differ in patient mix, coding practice, and clinical practice even if the same hospital system is involved. AdaPCLA without Δb already beats HALO with selected Δb: AUPRC 0.931 versus 0.907 for III->IV and 0.927 versus 0.832 for IV->III. Therefore, the improvement is not caused only by adding a target-prior correction at test time. Target code frequencies and λ are selected using a target adaptation split, never the target test set.
We also ran a single-seed 10k-sample eICU diagnosis-code sanity check using MIMIC-IV as source and eICU as target in a common diagnosis-code space. This is not full TSTR or full-modality validation, but AdaPCLA with Δb achieves the best performance across the reported metrics:
L1. We will add three limitations: (i) the zero-shot experiment is temporal MIMIC-version adaptation, not true multi-center transfer; (ii) the new baselines are supplementary single-run/snapshot evidence rather than full mean$\pm$std retraining; and (iii) the privacy checks are empirical diagnostics, not formal privacy guarantees.