- Rating
- 3
- Clarity
- 2
- Confidence
- 4
- Originality
- 1
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper reframes next-visit EHR prediction as a two-stage problem: (1) construct a patient-specific, structured candidate space ("Risk Horizon") and (2) rank within it. The candidate space is built from a typed graph combining deterministic coding hierarchies (ICD, ATC) with data-driven lagged-PMI cross-modal edges, embedded in hyperbolic (Poincare) space, with visits summarized as multi-head 'Central Events' and retrieval performed via directional 'risk cones'. LLMs are used strictly as constrained inference-time re-rankers. Experiments on MIMIC-IV and eICU show performance and improved hierarchy-consistency metrics, with ablations attributing most of the gain to geometry-aware retrieval.
Strengths and weaknesses
While the paper has some strengths like, (1) retrieval-then-rank decomposition & the candidate-space metrics, (2) strong ablations and honest failure analysis (trauma example is well chosen), there too many major weaknesses:
- The abstract and introduction repeatedly claim "competitive next-visit prediction performance", but on MIMIC-IV the geometry-only model (0.357 R@10) does not beat the simple Med-BERT baseline (0.402), and barely edges RETAIN (0.363). The wins come only after adding a 70B LLM reranker (0.425). This is a fair result, but the paper should state plainly that the core geometric contribution does not by itself beat the strongest sequential baseline, the framing currently implies otherwise. On eICU, geometry-only Risk Horizons (0.339) actually loses to RETAIN (0.381) and ties HALO; only the 70B reranker pulls ahead.
- The decisive results require Llama-3.3-70B or Meditron-70B at inference. The sequential baselines are tiny (d=64, 2-layer transformers). This is not a fair comparison of methods; it's partly a comparison of inference-time compute.
- The paper attributes gains to hyperbolic geometry, but the Euclidean Risk Horizons baseline (0.155 R@10) is poor, worse than Euclidean RAG in places, and far below every sequential method that it suggests an implementation or training-stability problem rather than a fair geometric ablation. A 0.073 diagnosis R@10 for a method using the same topology and pipeline is suspicious. Before concluding "hyperbolic is essential," I'd want evidence the Euclidean variant was tuned with equal care (e.g., matched normalization, learning rate, negative sampling). Right now the gap is too large to be credible as a clean geometry ablation.
- Checklist item 8 (Compute Resources): the justification describes "training details, data splits, hyperparameters"- not compute. The actual compute disclosure (single H100, latency table) exists elsewhere but the justification text is copy-pasted from the wrong item.
- Checklist item 16 (LLM usage): cites "Section 3.7," which does not exist (Section 3 ends at 3.4).
- Statistical testing: 5 seeds with std reported, but no significance tests on the close comparisons (e.g., RH-geometry vs RETAIN). Given overlapping error bars, claims of "matches or exceeds" need a test.
- Metrics like Oracle@K are ill defined and their relative ordering is not explained.
Questions
None.
Limitations
- A compute-matched/LLM-on-baseline experiment,
- A credible Euclidean ablation,
- Tightened metric definitions and toned-down causal language.
Paper formatting concerns
None that I noticed.
Final justification
Assessment under the General contribution type (updated). Evaluated as a General contribution per the authors' declared type, so methodological novelty and significance to the broader ML community carry primary weight. The central ingredients, hyperbolic embedding of coding hierarchies, directional entailment-style cones, retrieval-augmented candidate construction, and constrained LLM reranking are largely drawn from existing lines of work, so the principal contribution is their synthesis and the reframing of next-visit prediction as structured hypothesis-space construction. The rebuttal resolves my original soundness concerns (corrected Med-BERT and Euclidean results, a capacity-matched Transformer, 1B/3B/8B reranker ablations, a paired patient-cluster bootstrap, and a walk-back of the "competitive/exceeds" claims). With those addressed, my remaining reservations are the limited methodological novelty and the modest magnitude of the empirical advance: geometry-only Risk Horizons is statistically indistinguishable from RETAIN and the strengthened Transformer, and the clear gains require a 70B reranker, with smaller rerankers yielding only marginal improvements. Scores updated accordingly.
Rating 2 → 3, Quality 2 → 3, Clarity 1 → 2, Significance 3 (unchanged), Originality 1 (unchanged).
We thank the reviewer for the careful and constructive feedback, and for recognising the retrieval–ranking decomposition, candidate-space metrics, ablations, and failure analysis. The review prompted us to re-examine the reported baseline comparisons. During this verification, we identified two issues affecting the reported baseline results: (i) the Med-BERT aggregation for MIMIC-IV and (ii) the Euclidean Risk Horizons configuration. We corrected both issues, reran the affected experiments, and updated the corresponding analyses.
1. Geometry-only Risk Horizons and Sequential Baselines (Highlighted by AC: concern 1)
The reviewer correctly points out that the comparison should be evaluated against properly configured sequential baselines. We therefore audited the baseline evaluation pipeline and reran all affected experiments.
For Med-BERT on MIMIC-IV, we found a column-alignment error in the aggregation file used to prepare Table 1: the values reported as Recall@10 were taken from the Recall@20 column. A complete rerun confirms an overall Recall@10 of 0.311 and nDCG@10 of 0.402. The corrected result is also consistent with the relative performance of Med-BERT on eICU. We will replace the affected entries in the paper.
The reviewer also correctly notes that the original Transformer configuration was smaller than the other learned sequential baselines. We therefore reran it using a stronger configuration with hidden dimension 256, four layers, eight attention heads, and an FFN dimension of 1024. The strengthened Transformer obtains 0.362 Recall@10 and 0.473 nDCG@10 on MIMIC-IV, and 0.378 Recall@10 and 0.425 nDCG@10 on eICU.
† Updated results.
The corrected comparison leads to a more precise interpretation. RETAIN and the strengthened Transformer are the strongest sequential baselines, and geometry-only Risk Horizons achieves comparable performance: on MIMIC-IV, it obtains 0.357 Recall@10 and 0.447 nDCG@10, compared with 0.363/0.471 for RETAIN and 0.362/0.473 for the Transformer. We will therefore revise statements implying that geometry-only Risk Horizons consistently exceeds the strongest sequential models and instead describe it as achieving comparable aggregate performance while providing a fundamentally different, structured prediction interface.
Importantly, the corrected baseline comparison does not imply that the contribution lies only in the final LLM reranking stage. The primary contribution of this work is the Risk Horizons framework: a hyperbolic-structured retrieval formulation that explicitly constructs patient-specific hypothesis spaces before prediction. Unlike RETAIN and Transformer-based baselines, which directly score the entire clinical vocabulary, Risk Horizons first retrieves a clinically grounded candidate space using coding hierarchies, temporal associations, hyperbolic representations, and directional risk cones, and only then ranks candidates within this structured space. This retrieval stage already constitutes the proposed method, before any LLM reranking. It provides an explicit, auditable prediction process, exposes the supporting graph structure for each candidate, and separates candidate coverage, retrieval quality, and ranking quality into independently measurable components. Geometry-only Risk Horizons therefore embodies the central methodological contribution while achieving performance comparable to strong sequential baselines. The optional LLM reranker builds upon this structured hypothesis space, improving ranking accuracy while enabling different accuracy–cost trade-offs through smaller or larger models. We will therefore revise the manuscript to present the principal contribution as the hyperbolic structured retrieval formulation, with constrained LLM reranking providing complementary improvements.
2. Performance of Euclidean baselines (Highlighted by AC: concern 3)
The reviewer was correct to question the unexpectedly weak Euclidean Risk Horizons result. Auditing the experiments revealed that the Euclidean configuration did not match the final hyperbolic configuration. We corrected this mismatch and reran all seeds under the matched protocol. The corrected Euclidean Risk Horizons model achieves Recall@10 =0.2834 and nDCG@10 =0.3766, compared with the previously reported 0.155 and 0.190.
We will replace the affected results and revise the corresponding claims. The corrected experiment shows that the original result substantially underestimated the Euclidean model. Hyperbolic Risk Horizons nevertheless remains stronger under the matched configuration, achieving 0.357 Recall@10 and 0.447 nDCG@10. The corrected experiment leads to a more conservative estimate of the geometry advantage, but it does not change the main conclusion that the structured candidate-space formulation remains the primary contribution, with hyperbolic geometry providing an additional improvement under a matched experimental setting.
3. Compute fairness and the role of the LLM (Highlighted by AC: concern 2)
The RH+70B comparison is a task-level performance comparison, not a compute-matched comparison with the smaller sequential baselines. Risk Horizons does not introduce or eliminate this model cost; it reduces the complexity of the LLM’s task from unrestricted prediction over the complete clinical event vocabulary to reranking a compact, clinically grounded candidate set. This constrains the outputs, avoids task-specific fine-tuning, and makes supporting candidates inspectable.
To evaluate whether this constrained task can be handled by smaller models, we conducted additional experiments with Llama-3.2-1B and Llama-3.2-3B. The 3B model already slightly improves over geometry-only Risk Horizons, from 0.357 to 0.359 Recall@10 and from 0.447 to 0.467 nDCG@10, while requiring 2.92 seconds per step rather than 46.78 seconds for the 70B model. The 8B model provides nearly identical performance to the 3B model. Thus, meaningful reranking improvements do not require a 70B model, although the 70B configuration still provides the strongest accuracy.
These results show a clear family of accuracy–cost operating points. The 1B model is insufficient in the current setup, while the 3B and 8B models improve ranking at substantially lower cost than the 70B model. We will therefore clarify that the contribution is not that large LLM inference is inexpensive, but that restricting the reasoning task to a structured hypothesis space enables useful reranking with considerably smaller models.
4. Oracle@K definition and interpretation
Oracle Recall@K is defined in Appendix D as the upper-bound Recall@K achievable under perfect reranking of the retrieved Risk Horizon. It complements Candidate Recall and Risk-Horizon Recall@K by evaluating different stages of the proposed retrieval–ranking framework. Candidate Recall measures whether the ground-truth event appears anywhere in the initial candidate pool, Risk-Horizon Recall@K measures whether it is retained after the structured top-K retrieval stage, and Oracle Recall@K measures the maximum Recall@K achievable if those retrieved candidates were ranked perfectly. Comparing Oracle Recall@K with the final Recall@K therefore isolates the remaining ranking error after retrieval, while comparing Candidate Recall with Risk-Horizon Recall@K quantifies the effect of structured candidate selection. We will clarify these definitions in the revised manuscript.
5. Statistical significance tests for close comparisons
We added a paired patient-cluster bootstrap analysis with 10,000 replicates on the held-out test set. Patients, rather than individual visits, were resampled to preserve dependence among transitions from the same patient. RETAIN achieves a 0.006 higher Recall@10 than Geometry-only Risk Horizons (95% CI: [−0.002,0.013], p=0.11) and a 0.024 higher nDCG@10 (95% CI: [−0.004,0.066], p=0.10). Since both confidence intervals include zero, the differences are not statistically significant. In contrast, geometry-only Risk Horizons outperforms the corrected Med-BERT baseline by 0.046 in Recall@10 (95% CI: [0.031,0.059], p<0.001) and by 0.045 in nDCG@10 (95% CI: [0.032,0.057], p<0.001). These improvements over Med-BERT are statistically significant.
6. Others
The lagged-PMI relations are indeed associational rather than causal, as stated in line 139. We will also revise the wording throughout the manuscript.
For checklist item 8, we will add: “Each experiment uses one NVIDIA H100 GPU, eight CPU cores, 128 GB of memory, and at most 54.4 hours of runtime (for the HALO baseline).” For item 16, we will replace the incorrect reference to Section 3.7 with Section 3.