- Rating
- 5
- Clarity
- 4
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper proposes OPHD, a self-distillation framework for early disease risk prediction from EHR data. The key idea is to use follow-up EHR, available only during training, as privileged hindsight information to improve LLM-generated rationales. The rationale is generated only from prediction-time EHR, and the same rationale is then re-scored under perturbed follow-up views to identify stable token-level hindsight signals. These signals are further weighted by a task-grounded scorer to prioritize rationales that improve downstream risk prediction. Experiments on AD, PD, and ADRD cohorts show consistent improvements over conventional EHR models and several LLM-based reasoning baselines.
Strengths and weaknesses
Strengths:
- The paper tackles an important real-world problem, namely long-horizon risk prediction from sparse and noisy EHR data. The motivation is strong, especially because the method aims to use follow-up records during training without violating the inference-time constraint that only prediction-time EHR is available.
- The core idea is well designed, as keeping rationales on-policy and using follow-up EHR only to re-score the same rationale under perturbed privileged views helps avoid the train-test mismatch of directly imitating follow-up-conditioned rationales.
- The ablations, direct-imitation comparison, follow-up-window analysis, and additional pancreatic-cancer experiment support these design choices and the broader applicability of the framework. Overall, the paper is clear and technically solid.
Weaknesses:
- The practical significance remains somewhat limited. Although the added calibration analysis better contextualizes the results, the absolute AUPRC and positive predictive value (PPV) at 90% specificity remain low, and clinical actionability is not yet established.
- The additional pancreatic-cancer experiment broadens the evaluation beyond neurodegenerative disease, and the OHSU cohort provides evidence from an independent data source. However, strict cross-site transfer and calendar-time temporal-shift validation remain limited.
- While the specific combination of on-policy rationale generation, hindsight re-scoring, and task-grounded feedback is interesting, the individual components build on established ideas in privileged information, self-distillation, and scorer-guided learning. Thus, the novelty lies mainly in their coordinated integration rather than in each component individually. Nevertheless, the consistent gains across cohorts, the careful ablations, the comparison against direct follow-up-conditioned imitation, and the additional analyses make the submission convincing overall.
Questions
- OPHD uses follow-up EHR during training. Are the gains mainly coming from records that are very close to the diagnosis or index time? What happens if those near-index records are removed?
- The reported positive predictive value (PPV) is low even at 90% specificity. Can the authors show calibration results or decision-curve analysis to clarify whether the model would be useful in practice?
- The evaluation is limited to neurodegenerative disease cohorts. Can the authors provide evidence that OPHD is robust under temporal shift, site shift, or evaluation on an independent external dataset?
- The method uses generated rationales, but the main results focus on prediction scores. Can the authors show examples or clinician-reviewed failure cases to demonstrate that OPHD improves rationale quality rather than only prediction performance?
Limitations
The limitations are better addressed. The authors acknowledge that generated rationales should be treated as intermediate model outputs rather than clinical explanations, and the rebuttal adds a broader disease-domain experiment and calibration analysis. However, the discussion should still more directly address the low absolute PPV, lack of strict cross-site transfer or calendar-time temporal-shift validation, possible site-specific EHR artifacts, and fairness across demographic groups.
Paper formatting concerns
No
Final justification
I recommend a score of 5: Accept. The paper is technically sound, and the additional pancreatic-cancer experiment, three-year follow-up cutoff analysis, calibration results, and rationale-quality analysis substantially addressed my main concerns. Some limitations remain, including low absolute PPV and limited strict shift and fairness evaluations, but I do not consider them sufficient grounds for rejection.
We thank Reviewer G94i for the suggestions and respond to the comments as follows.
Q1: Other LLMs (changing either the rationale generator or the scorer)
R1: For the rationale generator, we would respectfully highlight that Appendix F.2 and Figure 6 provide a backbone analysis. Specifically, we replace the default Qwen3-4B generator with Gemma3-4B, Qwen3-8B, and Ministral-3 8B (newly added) while following the same training and evaluation protocol on the ADRD cohort. The results are shown below.
OPHD achieves comparable AUROC, AUPRC, sensitivity at 90% specificity, and PPV at 90% specificity across all four backbones, with the larger 8B models providing only modest additional improvements. The consistency across Gemma, Qwen, and Ministral model families, as well as across 4B and 8B scales, indicates that the proposed hindsight-distillation mechanism is not tied to a particular rationale-generator backbone.
We also conduct a complementary scorer analysis by fixing the Qwen3-4B rationale generator and replacing the default Qwen3-0.6B scorer with two compact models from different families: LFM2.5-1.2B-Instruct and Gemma 3-1B. Each scorer is retrained within the OPHD pipeline because it provides both the task-grounded feedback during training and the final risk prediction.
As shown in the table, performance remains comparable across all three scorers. LFM2.5-1.2B-Instruct achieves the strongest overall results, while the 0.6B Qwen scorer remains competitive despite its substantially smaller size. Unlike the rationale generator, the scorer does not perform open-ended clinical reasoning or text generation; it only estimates the outcome from the prediction-time EHR and the generated rationale and provides a scalar task-grounded feedback signal. This comparatively constrained classification role can be handled effectively by compact language models. The consistency across Qwen, LFM, and Gemma scorers further indicates that the performance of OPHD is not tied to a particular scorer family and supports the use of a small scorer as a computationally efficient design choice.
Overall, across LLMs from different model families used as either the rationale generator or the scorer, OPHD consistently outperforms the baselines, demonstrating that its performance advantage is not tied to a particular model backbone.
Q2: Test the proposed method on different benchmarks
R2: To the best of our knowledge, existing public EHR benchmarks are not directly aligned with the long-horizon EHR-based early prediction setting considered in our study. Existing clinical datasets differ substantially from our target setting. Acute-care EHR benchmarks such as MIMIC, eICU, and HiRID are largely hospitalization- or ICU-visit-centered rather than natural longitudinal EHR populations; their observation windows, event density, and outcomes are shaped by specific encounter episodes and are therefore more suitable for acute-care prediction tasks. Disease-specific resources such as PPMI, PDBP, and ADNI emphasize standardized cognitive assessments and recruit eligible patients for close monitoring with imaging, biospecimens, genetic data, and other biomarkers. However, these cohorts are protocol-driven with designated healthcare visits and measurements, rather than routine real-world EHR benchmarks.
Our focus on neurodegenerative diseases is deliberate. AD, PD, and related dementias affect large and rapidly growing patient populations suffering from progressive cognitive and functional deterioration, where earlier identification may support care planning and monitoring, risk stratification, and disease-modifying clinical trials. At the same time, these diseases are particularly challenging for long-horizon prediction because they progress over long periods, during which early signals are often sparse, heterogeneous, indirect, and clinically nonspecific. In contrast to diseases for which routinely measured indicators can provide relatively direct evidence of risk or disease status, neurodegenerative diseases generally lack a single simple and low-cost clinical test that reliably identifies long-term risk during the preclinical period. This combination of substantial impact and limited early observability makes neurodegenerative diseases a particularly appropriate setting for evaluating whether follow-up trajectories can improve the interpretation of subtle prediction-time evidence and, ultimately, downstream predictive performance.
Importantly, although no predefined community benchmark exists for the studied problem, our evaluation is not limited to a single institution-specific dataset. We included All of Us, one of the largest nationwide research programs linking longitudinal EHR with participant-level health information, which is available to registered researchers through a standardized controlled-access process and the secure Researcher Workbench. We further evaluated the method on an independent OHSU EHR cohort. Together, these two data sources support three disease cohorts: AD, PD, and ADRD. We believe this multi-source, multi-disease evaluation provides a meaningful robustness assessment in the absence of a directly aligned public benchmark.
In response to the reviewer’s suggestion, we further evaluated OPHD on a supplementary three-year ADRD early-risk prediction cohort constructed from MIMIC-IV using the same cohort-construction and data-preparation pipeline as in the main experiments. We used a three-year rather than five-year prediction horizon to accommodate MIMIC-IV’s hospitalization-centered sampling frame and comparatively limited longitudinal coverage. Using the same OPHD framework and evaluation protocol, OPHD achieved the best performance among all evaluated methods across AUROC, AUPRC, Sens@90, and PPV@90, suggesting that its performance advantage is preserved under a different data-generating process and cohort structure.
Q3: More insights or examples showing why more complicated methods (GRAPE, MUSE, MOTOR) are even less effective than naive baselines
R3: The main issue is not model complexity, but the supervision available for learning from noisy long-horizon EHR. GRAPE and MUSE learn graph-based representations from structured patient–feature relationships, while MOTOR learns general temporal EHR representations through pretraining. However, for the target disease, these methods ultimately rely mainly on prediction-time EHR and outcome labels, without intermediate supervision indicating which early observations are genuinely predictive.
This limitation is especially important in long-horizon prediction. Several years before diagnosis, EHRs might contain common comorbidities, medications, and healthcare-utilization events that may be unrelated to the future disease outcome, whereas truly informative signals are sparse, weak, and clinically nonspecific. The final outcome label indicates whether the disease eventually occurs, but does not reveal which early events are meaningful and which are incidental. Consequently, even sophisticated graph or pretrained EHR models may emphasize dominant but nonspecific statistical patterns and struggle to distinguish useful weak signals from background noise. This is the central challenge described in our motivation.
Zero-shot and Multi-sample methods are simple only in terms of task-specific training. They still benefit from clinical and semantic knowledge acquired during large-scale LLM pretraining, which can help connect several heterogeneous and individually nonspecific observations into a coherent clinical pattern. Multi-sample further reduces dependence on a single incomplete interpretation. Therefore, the results mainly reflect differences in available knowledge and supervision, rather than more complicated architectures being inherently less effective.