- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper presents a multimodal survival model M-CADENCE that takes into consideration structured acyclic priors with attention-based propagation with 4 main modalities (vital signs and laboratory, statics demo, diagnostics codes, free text radiology).
Strengths and weaknesses
The paper presents a multimodal survival model M-CADENCE that takes into consideration structured acyclic priors with attention-based propagation with 4 main modalities (vital signs and laboratory, statics demo, diagnostics codes, free text radiology).
- One of my main concern in this paper is that the temporal representation does not appear to preserve the irregular event structure of EHR data. Dynamic measurements are aggregated into six fixed windows and each variable's entire trajectory is subsequently compressed into a single token before graph propagation. What will happen is that exact timestamps, inter-measurement intervals, ordering within a window, and measurement frequency may be lost. Moreover, the learned adjacency relates variable-level summaries over the full observation window rather than modeling time-specific interactions between measurements. The node-masking mechanism addresses variables that are completely unobserved for a patient, but it does not explain how intermittent missingness and irregular repeated measurements are represented. A variable measured once and the same variable measured repeatedly during deterioration both receive a node-level mask value of one. Therefore, clinically informative observation patterns—such as measurement frequency, time since the previous test, and the decision to repeat a test—may be lost unless they are explicitly incorporated into the inverted token embedding. This is especially important when multiple measurements fall within the same temporal window. Let me give you an example, a normal urine result at hour 1 followed by an abnormal result at hour 3 may be collapsed into a single aggregated value, potentially removing the transition from normal to abnormal and this is important especially in ICU and in the case of sepsis where infection is a hard core signal and the fact that it changes from one timestamp to another is beyond informative. Can you specify the within-window aggregation rule, how the entry-level mask (M_i\in{0,1}^{L\times D}) is used by the encoder, and whether measurement counts, timestamps, time-since-last-observation, and missingness indicators are included as features.
- During the preprocessing, dynamic variables are aggregated into temporal windows. Features exceeding a dataset-specific missingness threshold are being removed fully. What is the he missingness threshold used for each dataset?
- In Equation 2: A^{(m)} = W^{(m)} \circ \sigma\left( \frac{|W^{(m)}|-\tau}{\gamma} \right). (in the 3.3 Modality-Aware Acyclic Structure Learning) the soft-thresholding is not acyclic nor sparse, the actually sigmoid in the equation is strictly positive for finite inputs, this transformation generally attenuates small entries but does not set them exactly to zero. Unless entries of (W) themselves become exactly zero, almost every entry of (A) remains nonzero. So defining (E^{(m)}) as A_{ij}^{(m)}\neq0) gives conflict, did you apply any numerical threshold during the forward pass before GIN propagation and attention (because if a hard thresholding is used only post hoc then the adjacency actually used by the model is a softly gated weighted matrix rather than a sparse DAG).
- The paper worked on 3 main ablations (Mask off, A=0 and Random A...), however the main point in this contribution in that the acyclic structural improves multimodal survival prediction from my understanding. So by this ablation study, it doesn't highlight the core point of this paper. What would be interesting is to compare M-CADENCE to the same architecture trained with a learned sparse adjacency but without the DAG penalty.
- The model does not fully learn the direction of relationships between modalities. The paper already mention that they do first choose an order between modalities and only allow edges that follow this order. The model learns how strong an allowed connection should be, but it cannot choose the opposite direction. For example, if the predefined order allows: \text{vital signs} \rightarrow \text{laboratory tests}, the model can learn the strength of this relationship, but it cannot learn: \text{laboratory tests} \rightarrow \text{vital signs}. In practice, clinical relationships may work in both directions. Abnormal vital signs may lead a clinician to order a laboratory test, while the laboratory result may then influence monitoring and treatment. Therefore, part of the learned cross-modal structure reflects the authors' predefined ordering rather than relationships discovered entirely from the data. I would suggest to test different modality orders or allow bidirectional relationships.
- For high-dimensional data such as ICD codes and radiology embeddings, the model groups the original features into a smaller number of pooled nodes. However, these groups are created separately for each patient. For example, pooled node 1 may represent sepsis and pneumonia codes for one patient, but heart failure and kidney disease codes for another patient. The model then learns one shared edge such as:\text{pooled node 1} \rightarrow \text{pooled node 3}. It is difficult to give this edge a stable clinical meaning because pooled node 1 may represent different information for different patients. This does not necessarily make the model ineffective for prediction, but it weakens the claim that the learned adjacency is an interpretable clinical DAG. The authors should examine whether the pooled nodes have consistent meanings across patients and random seeds.
Questions
- One of my main concern in this paper is that the temporal representation does not appear to preserve the irregular event structure of EHR data. Dynamic measurements are aggregated into six fixed windows and each variable's entire trajectory is subsequently compressed into a single token before graph propagation. What will happen is that exact timestamps, inter-measurement intervals, ordering within a window, and measurement frequency may be lost. Moreover, the learned adjacency relates variable-level summaries over the full observation window rather than modeling time-specific interactions between measurements. The node-masking mechanism addresses variables that are completely unobserved for a patient, but it does not explain how intermittent missingness and irregular repeated measurements are represented. A variable measured once and the same variable measured repeatedly during deterioration both receive a node-level mask value of one. Therefore, clinically informative observation patterns—such as measurement frequency, time since the previous test, and the decision to repeat a test—may be lost unless they are explicitly incorporated into the inverted token embedding. This is especially important when multiple measurements fall within the same temporal window. Let me give you an example, a normal urine result at hour 1 followed by an abnormal result at hour 3 may be collapsed into a single aggregated value, potentially removing the transition from normal to abnormal and this is important especially in ICU and in the case of sepsis where infection is a hard core signal and the fact that it changes from one timestamp to another is beyond informative. Can you specify the within-window aggregation rule, how the entry-level mask (M_i\in{0,1}^{L\times D}) is used by the encoder, and whether measurement counts, timestamps, time-since-last-observation, and missingness indicators are included as features.
- During the preprocessing, dynamic variables are aggregated into temporal windows. Features exceeding a dataset-specific missingness threshold are being removed fully. What is the he missingness threshold used for each dataset?
- In Equation 2: A^{(m)} = W^{(m)} \circ \sigma\left( \frac{|W^{(m)}|-\tau}{\gamma} \right). (in the 3.3 Modality-Aware Acyclic Structure Learning) the soft-thresholding is not acyclic nor sparse, the actually sigmoid in the equation is strictly positive for finite inputs, this transformation generally attenuates small entries but does not set them exactly to zero. Unless entries of (W) themselves become exactly zero, almost every entry of (A) remains nonzero. So defining (E^{(m)}) as A_{ij}^{(m)}\neq0) gives conflict, did you apply any numerical threshold during the forward pass before GIN propagation and attention (because if a hard thresholding is used only post hoc then the adjacency actually used by the model is a softly gated weighted matrix rather than a sparse DAG).
- The paper worked on 3 main ablations (Mask off, A=0 and Random A...), however the main point in this contribution in that the acyclic structural improves multimodal survival prediction from my understanding. So by this ablation study, it doesn't highlight the core point of this paper. What would be interesting is to compare M-CADENCE to the same architecture trained with a learned sparse adjacency but without the DAG penalty.
- The model does not fully learn the direction of relationships between modalities. The paper already mention that they do first choose an order between modalities and only allow edges that follow this order. The model learns how strong an allowed connection should be, but it cannot choose the opposite direction. For example, if the predefined order allows: \text{vital signs} \rightarrow \text{laboratory tests}, the model can learn the strength of this relationship, but it cannot learn: \text{laboratory tests} \rightarrow \text{vital signs}. In practice, clinical relationships may work in both directions. Abnormal vital signs may lead a clinician to order a laboratory test, while the laboratory result may then influence monitoring and treatment. Therefore, part of the learned cross-modal structure reflects the authors' predefined ordering rather than relationships discovered entirely from the data. I would suggest to test different modality orders or allow bidirectional relationships.
- For high-dimensional data such as ICD codes and radiology embeddings, the model groups the original features into a smaller number of pooled nodes. However, these groups are created separately for each patient. For example, pooled node 1 may represent sepsis and pneumonia codes for one patient, but heart failure and kidney disease codes for another patient. The model then learns one shared edge such as:\text{pooled node 1} \rightarrow \text{pooled node 3}. It is difficult to give this edge a stable clinical meaning because pooled node 1 may represent different information for different patients. This does not necessarily make the model ineffective for prediction, but it weakens the claim that the learned adjacency is an interpretable clinical DAG. The authors should examine whether the pooled nodes have consistent meanings across patients and random seeds.
Limitations
Yes
Paper formatting concerns
N/A
Final justification
Taking into consideration the clarifications of the authors and their responses to my raised question
We thank the reviewer. The Eq. 2 analysis is correct, and we give empirical results on this front below. All numbers are five-seed means, paired by seed; p-values where significant.
W3/Q3. "the soft-thresholding is not acyclic nor sparse … did you apply any numerical threshold during the forward pass before GIN propagation and attention"
The reviewer is right that the forward graph is dense and only post hoc thresholded subgraphs are acyclic. The gate is strictly positive, so A holds no exact zeros, and the only exact zeros are the reverse-precedence cross-modal half, which is structural. No hard threshold is applied in the forward pass, the attention bias being log(|A|+ε)·β and the GIN layers receiving the soft A. Defining E = {A_ij ≠ 0} will be edited, as will Section 3.5's "the GIN tower is restricted to the structure surviving soft thresholding", since the GIN aggregates over the dense soft A.
Zeroing every entry below τ = 10⁻³ while keeping the soft bias on survivors removes 62–99% of off-diagonal entries and changes discrimination by ΔC^td = −0.00016, and the thresholded graph passes a topological sort in 23 of 25 runs. The forward pass still runs on the dense A, with the mass carrying the prediction on an acyclic high-magnitude subgraph.
The soft gate does work of its own, since at τ = 0.05 deleting sub-threshold entries costs −0.033 C^td on MC-MED, so real signal runs through low-magnitude paths, whereas at the stricter loss-free point, τ = 10⁻³, 23 of 25 dataset-seed graphs are acyclic. We will report both and drop "the operational regime" from E.2.
W4/Q4. "it doesn't highlight the core point of this paper … compare M-CADENCE to the same architecture trained with a learned sparse adjacency but without the DAG penalty"
We ran the same architecture with L1 kept and the acyclicity penalty off (λ_DAG = 0) on all five datasets, and the effect is small everywhere, |ΔC^td| ≤ 0.0042, the one significant difference being a nominal +0.0028 on MIMIC-IV (p = 0.035), so the penalty is at best neutral.
λ_DAG = 0 is not by itself a no-DAG model as each intra-modal W is initialised strictly lower-triangular, so we also ran the non-triangular arm, a dense initialisation with λ_DAG = 0 and L1 kept, five seeds on the three unpooled datasets. It is lower in the mean on all three (|Δ| ≤ 0.0031) and in 10 of 15 seed-pairs, though we do not claim the parameterisation carries prediction either. Removing the sparsity term as well does change the structure, and the thresholded graph is then cyclic in 5 of 5 seeds under both initialisations, against 23 of 25 acyclic, so the acyclicity is produced by the sparsity and the log-determinant penalty, the expensive part of NOTEARS and DAGMA, is not needed to obtain it.
The attention-bias strength matters more, since on eICU, varying only β with everything else fixed, β = 0 gives 0.8769, β = 1 gives 0.9021 (+0.0252, p = 0.010) and β = 2 gives 0.9062 (+0.0293, p = 0.001), with Spearman ρ = 0.832, p = 1.2 × 10⁻⁴ over 15 runs, so accuracy rises with the bias across this range and on a dataset with no pooling at all.
The other controls agree: at the same parameter count and L1, β = 0 is negative on four of five and in 18 of 25 comparisons (p = 0.043); retraining without both, rather than Table 2's inference-time A = 0, is negative on all five (eICU −0.0593); and freezing the intra-modal graph is worse than learning it on HiRID (−0.0050, p = 0.016).
We therefore sharpen our claims to graph-biased propagation, the cross-modal gating, and how strongly the graph is fed into attention. Your control is why we will retitle the paper and rewrite the abstract's opening around that structural bias rather than DAG learning; no result changes.
W5/Q5. "the model can learn the strength of this relationship, but it cannot learn: laboratory tests → vital signs … test different modality orders or allow bidirectional relationships"
Your example sits inside a single modality, where nothing is constrained, vital signs and laboratory values both living in the
dynamicmodality, whose adjacency is a full square matrix, the lower-triangular form being only the initialisation. In the gated adjacency the model uses, every pair of dynamic features carries weight in both directions on all five datasets, so lab → vital and vital → lab compete freely, differing in magnitude by 2.4×–6.3× at the median, and no two-cycle survives thresholding at τ = 10⁻³.The ordering static ≺ icd ≺ dynamic ≺ rad applies only between modalities, where each allowed pair gets one scalar gate. That is a design assumption; we will state it more clearly and include bidirectional results. No predictive result depends on the choice, and the one place where it might matter is Section 4.7, where "recovers a cross-modal precedence" overstates the case; we will restate that as gate magnitudes learnt within an imposed precedence. The permutation you suggest, fully reversing the order (rad, dynamic, icd, static), is non-significant on both datasets tested, MIMIC-IV +0.0013 (p = 0.78) and MC-MED −0.0048 (p = 0.20).
W1/Q1. "… does not appear to preserve the irregular event structure … Can you specify the within-window aggregation rule, how the entry-level mask … is used by the encoder, and whether measurement counts, timestamps, time-since-last-observation, and missingness indicators are included as features"
We agree with the reviewer's clinical intuition that high-frequency variance, such as an acute urine abnormality at hour 3, is a critical signal, and our fixed windows do smooth over sub-window transitions, though they preserve the broader trajectory.
Aggregation. Every dynamic feature is a mean within its window: the event-mean on MIMIC-IV; an hourly mean then a nanmean on eICU and HiRID; a 1 h window on MC-MED and HiRID-CIRC. The six windows are 4 h on eICU, MIMIC-IV and HiRID (App. B), so your urine example is a 4-hour collapse there and 1-hour elsewhere, never a whole-trajectory one. At the shortest horizon we evaluate, this representation is strongest against every dynamic baseline, with eICU 24 h dynamic AUC 0.965 against DySurv 0.928 and Dynamic-DeepHit 0.870.
Mask. The tensor has the shape we wrote, but broadcasts one presence bit per patient and modality, as App. B already calls it, a modality-presence mask. The encoder uses it to exclude absent nodes as attention keys and to drop them from GIN aggregation by column-masking the adjacency, and never enters the token embedding. Because dynamic and static are always present, it only fires on the two optional modalities, and we will restate it as M_i ∈ {0,1}^M. Imputation is forward-fill within patient plus a train-fold population mean, no backward fill. With extra missingness in train and test we keep the full lead over Dynamic-DeepHit to a 50% rate (MIMIC-IV +0.0346 → +0.0199; MC-MED +0.0128 → +0.0102).
What is kept. Each variable's token is processed by a per-variable Linear(6 → 128) over the ordered window vector, so ordering across windows, trend and direction are stable, and the adjacency is shared across windows by design, acting as a variable-level prior rather than a lagged transition matrix. Event time enters on the outcome side, over J = 10 ordered intervals with a pairwise ranking term, which helps at MIMIC-IV 48 h dynamic AUC 0.873 against DySurv 0.833 and Dynamic-DeepHit 0.816.
The feature you propose is already implemented and tested, an observation-rate channel in the inverted token plus an observation-scaled DAG bias, and is performance-neutral (MIMIC-IV at 10% dropped: 0.8026 without, 0.7994 and 0.8080 with). A continuous-time encoder is the right next step and we will state it in revised Limitations; as it stands, the representation holds its margin at realistic missingness ranges.
W2/Q2. "What is the … missingness threshold used for each dataset?"
Only MC-MED applies a missingness-fraction rule, lab and vital columns ≥ 85% missing being dropped. The other four datasets use fixed variable lists from their respective benchmarks: an 18-name lab exclusion list on eICU; itemid lists on MIMIC-IV (10 vitals, 25 labs) plus the top-500 prior-admission ICD codes; the 18-variable HiRID-benchmark set on both HiRID sets. The paper's single-threshold description is overly general and we will correct it per dataset. On MC-MED, the one dataset where we have a fraction rule, our matched comparison is strongest, with the same two modalities and no pooling for every model, M-CADENCE 0.824 C^td to CUTS+'s 0.795.
W6/Q6. "pooled node 1 may represent different information for different patients … examine whether the pooled nodes have consistent meanings across patients and random seeds"
SoftPool's assignment network takes a single scalar, so membership depends dynamically on a feature's value, and permuting all 768 radiology dimensions moves the pooled output by 5.6×10⁻⁹. Pooled node k has a stable functional definition but no stable clinical reference, so "pooled 1 → pooled 3" has no code-level reading. No interpretability claim rests on a pooled node's identity, as we stated in Section 3.3; the pooled nodes serve computational capacity, and Section 4.6 already restricts the LLM panel to the dynamic and static parts of A, where feature identity is preserved.
Within these unpooled blocks, magnitude ordering reproduces at Spearman 0.67–0.90, and a strict consensus subgraph survives, HiRID-CIRC having 6 edges in the top-50 of every seed (5 from an arterial-lactate hub) and HiRID 3. On the 10-LLM panel, our edges beat the negative controls in all six (dataset, K) cells on effect size, at Cohen's d=1.78 on MIMIC-IV against the structure learners' 1.07 and 0.96.
Pooling does not carry the predictive edge either, since three of the five datasets use no pooling at all (eICU, HiRID, HiRID-CIRC) and we lead the structure-learning models on all three (vs CUTS+: 0.904/0.853, 0.850/0.839, 0.794/0.768).