- Rating
- 3
- Clarity
- 3
- Confidence
- 5
- Originality
- 3
- Quality
- 3
- Significance
- 2
Read review
Summary
This manuscript provided a review to foundation models for wearable motion sensing. Systematically examines how data, model, and training choices, such as sensor placement, sampling rate, architecture, pretraining objective, and scale. This study also evaluated across 15 datasets covering activity recognition, freezing-of-gait detection, and disease prediction, it delivers state-of-the-art results and practical guidance for building generalizable wearable motion representations.
Strengths and weaknesses
This manuscript explored how pre-training objectives, sensing configurations, scale, and downstream tasks jointly shape transferable motion representations. The authors put together large amount of wearable motion data including multiple datasets. According to those comparisons of SSL models and supervised baselines across HAR dataset, FoG tasks, and disease prediction tasks, this study summarized the finding of self-supervised pretraining consistently outperforms supervised training from scratch across task categories, and the result suggests strong representations learned from unlabeled population cohorts regardless of the specific downstream application. However, this is a well-established finding, the wearable/time-series community has been converging on the same conclusion since roughly 2022. The claimed finding mirrors the established narrative from NLP(BERT, GPT) and vision (MAE, SimCLR, MoCo), where SSL on large unlabeled corpora (e.g., 18M+ hours) consistently beats supervised-from-scratch on limited labeled data.
There are limitations of the novelty for this study. For example, as conclusion (line 383-385) mentioned, "we find that self-supervised pretraining consistently improves transfer over supervised training from scratch, but no single objective dominates across all task families". For the first half of this conclusion, SSL improves over supervised from scratch, a well established and discussed topic. It's not a contribution on this manuscript. I agree with that the second half of this conclusion has modest novelty but not entirely surprising, because the time-series and vision SSL communities have observed this for a while, e.g., SimCLR, MoCo these contrastive methods tend to favor discrimination tasks and BERT-style masked reconstruction tends to favor dense/generative understanding.
In addition, the 18.2M hours figure is an aggregation of existing public datasets, not a newly collected corpus, this should be stated more clearly upfront rather than presented in a way that implies data collection as a contribution. The abstract's phrasing does technically acknowledge this, but the overall framing still gives the impression of a data contribution. The real contributions are the controlled experimental framework and the empirical findings
Questions
The suggestion is consider to submit this manuscript to a journal might be more competitive. The work is solid and carefully done, as authors mentioned at the end, it's a comprehensive cookbook for wearable motion representation learning, but at its core it's more about pulling things together and measuring them than actually introducing something new. The "Inertia-1" branding and "fully open exploration" framing somewhat overstate the novelty. The core deliverable, a systematic sweep of design choices across existing datasets and architectures, reads more as a large-scale benchmarking or survey effort than a novel methodological contribution.
Limitations
Yes.
Paper formatting concerns
No.
Final justification
Based on the authors' responses, I am raising my score to 3, as a borderline rating, and adjusting my originality assessment upward accordingly. My remaining hesitation is about significance rather than technical soundness, and I will follow the discussion with the other reviewers and the AC with an open mind.
Thank you for your detailed feedback. We respectfully believe this assessment overlooks several central contributions of the paper and places disproportionate emphasis on one high-level result. We clarify the scope, novelty, and primary findings of the work point by point below:
We first want to address the reviewer’s comments regarding the novelty of this work. We would like to note that the originality of this work is consistent with NeurIPS's own stated originality criteria in the reviewing guidelines. The General track's Originality criterion is explicit in that
“originality does not necessarily require introducing an entirely new method. Rather, a work that provides novel insights by evaluating existing methods, or demonstrates improved efficiency, fairness, etc. is also equally valuable.”
Additionally, the Significance criterion similarly is evaluated as:
“unique conclusions about existing data, or a unique theoretical or experimental approach.”
By these criteria, we believe Inertia-1's unification of a fragmented experimental space, and the conclusions that unification makes possible, fall exactly within the type of contribution recognized by these criteria.
Additionally, while we agree that SSL-beats-supervised-from-scratch is well established outside wearable sensing, we would like to clarify that this is not the paper's central contribution. We believe the review's framing conflates one confirmatory result with the paper's actual claims. The inclusion of the SSL and supervised methods comparison is used to validate that our experimental framework behaves as expected, that pretraining was successful, before we use it to evaluate the questions the paper is actually about. The paper's main claims, which we don't believe are addressed in the review, are:
To the best of our knowledge, none of these are established findings in NLP, vision, or the wearable/time-series literature; each requires the kind of controlled, cross-cutting comparison that no single prior wearable motion study has run. We certainly welcome any concrete suggestions from the reviewer on prior studies to compare with.
To summarize, we believe the review reflects several misunderstandings regarding the paper’s contribution, scope, and positioning. The review’s novelty assessment centers primarily on one confirmatory finding while not engaging with the paper’s main contributions; we therefore respectfully believe that the reviewer’s assessment of limited novelty is not supported by the specific arguments provided in the review.
Additionally, we appreciate the reviewer’s comments regarding the data corpus and how it is presented in this work. We would like to respectfully identify specific instances in the text in which we address this, including:
Lastly, regarding the reviewer’s suggestion to submit this work to a journal rather than NeurIPS, while we appreciate the suggestion, we respectfully disagree and clarify below both the scope of our contribution and its fit within NeurIPS.
Scope of Contribution. Inertia-1 is not a survey or a simple aggregation of prior results. Our work (1) unifies 15 heterogeneous wearable motion datasets under a controlled training and evaluation framework, (2) systematically compares representative pretraining objectives across HAR, FoG, and disease prediction, (3) characterizes how sampling rate, window length, axis representation, input domain, model scale, and data scale affect transfer, and (4) studies generalization across body placements and sensor modalities, including the complementary benefits of multi-stream sensing. These conclusions require training and evaluating more than 1,000 models under matched protocols and cannot be obtained by summarizing the existing fragmented literature.
Nature of Novelty. The paper does not claim novelty from introducing a new pretraining objective. Its novelty lies in the experimental framework and the previously unavailable conclusions enabled by it. In particular, we show that objective differences widen substantially beyond standard HAR, that increasing data diversity is more reliable than increasing model size alone, that sensing choices have task-dependent effects, and that wrist-accelerometer pretraining transfers across placements and sensor types. We therefore respectfully disagree with the characterization that the work merely “pulls things together and measures them.”
Precedent at NeurIPS. NeurIPS has clear precedent for systematic empirical studies whose primary contribution is to characterize existing methods, disentangle previously conflated design choices, and derive new conclusions through controlled experimentation [1] [2] [3][4]. These works demonstrate that a contribution need not introduce a new learning objective or architecture when its experimental design enables insightful new understanding. We believe Inertia-1 fits this contribution style by unifying previously fragmented wearable-motion settings and deriving findings that individual prior studies could not establish.
References:
We sincerely thank the reviewer once again for their time and constructive feedback. To support the community and enable future research, we remain committed to fully open-sourcing our research. We hope our detailed responses and the additional experiments have addressed all of your concerns, and we would be happy to answer any remaining questions during the discussion period. We would be very grateful if you might consider raising your score and championing the paper in light of these updates.