- Rating
- 5
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The authors introduce AnyMo, a geometry-aware framework for setup-agnostic wearable IMU motion understanding. The method addresses the problem that inertial signals strongly depend on sensor placement, mounting orientation, device hardware, and sampling protocol, which limits transfer across wearable setups and datasets. AnyMo first uses physics-grounded simulation over dense body-surface placements to generate plausible synthetic IMU signals from human mesh/skeleton motion. It then pre-trains a spatio-temporal graph encoder with masked cross-view predictive contrastive learning, encouraging the model to recover setup-stable full-body motion representations from sparse and setup-specific IMU observations. These representations are discretized into full-body IMU tokens through a product-quantized tokenizer and aligned with a language model using motion-language pre-training and multi-task contrastive instruction tuning. The resulting model supports zero-shot activity recognition, bidirectional IMU-text retrieval, and wearable motion captioning. The main experiments are conducted on 14 unseen human activity recognition datasets, with additional retrieval and captioning evaluations on held-out Nymeria subjects and zero-shot EgoExo4D transfer.
Strengths and weaknesses
Strengths
-
The core idea is compelling. Instead of treating setup variation as arbitrary noise, the authors model it as structured body-surface variation. This provides a meaningful geometry- and physics-based inductive bias for learning representations that are more robust to wearable placement and orientation changes.
-
The proposed dense body-surface IMU simulation is technically interesting. Compared with fixed joint-centric or sparse placement simulation, simulating IMU signals over plausible surface placements and local sensor frames provides a richer and more realistic source of setup variation.
-
By introducing full-body IMU tokens and aligning them with a language model, the paper attempts to support zero-shot recognition, cross-modal IMU-text retrieval, and wearable motion captioning within a unified framework.
-
The ablation study strongly supports the importance of the two main technical components. Removing geometry-aware simulation or masked cross-view predictive contrastive learning causes a large performance collapse, suggesting that both realistic setup variation and sparse-to-full predictive pre-training are central to the method.
-
The retrieval and captioning results suggest that the learned IMU tokens contain meaningful motion-language information.
Weaknesses
-
The authors' central claim is setup-agnostic wearable motion understanding, but the experimental evidence does not directly isolate setup variation enough. The main zero-shot recognition evaluation is based on cross-dataset transfer, which is useful but also conflates many factors: sensor placement, orientation, hardware, sampling rate, subject population, dataset protocol, preprocessing, and label definitions. A stronger validation would include controlled experiments where only one setup factor changes at a time.
-
Although AnyMo obtains the best average performance across the 14 zero-shot HAR datasets, the per-dataset behavior is mixed. UniMTS remains competitive and outperforms AnyMo on some individual datasets. This does not invalidate the contribution, but it weakens the claim that the model is uniformly generalist across wearable setups. Also, the absolute average zero-shot performance remains modest, with 35.7 accuracy and 29.5 macro-F1. Given the difficulty of the setting, this may be understandable, but the authors should moderate claims about robust in-the-wild understanding and provide a deeper failure analysis.
-
The method depends heavily on Nymeria-style supervision, including body mesh/skeleton motion, anatomical segment definitions, atomic-action text annotations, and real IMU streams for estimating noise priors. The large drop when removing geometry-aware simulation supports the method, but it also reveals a strong dependence on dense motion supervision for generating synthetic IMU data. Many wearable datasets contain only sparse real IMU streams and activity labels, without mesh or skeleton motion. The authors should discuss more explicitly whether AnyMo can be trained, adapted, or scaled in settings where such dense motion supervision is unavailable.
-
The evidence for synthetic-to-real alignment is mainly qualitative. Figure 6 shows encouraging UMAP visualizations where real and synthetic embeddings appear better mixed in the full model, but UMAP is sensitive to sampling, hyperparameters, and random seeds. Since synthetic-to-real transfer is a central mechanism of the paper, the analysis would be stronger with quantitative alignment metrics, such as real/synthetic domain classification accuracy, nearest-neighbor mixing, MMD distance, silhouette scores by activity versus domain, cluster purity, or real-to-synthetic retrieval within the same activity.
-
The motion-language evaluation is promising but not fully sufficient to support strong claims about open-ended motion understanding. Retrieval performance is strong on held-out Nymeria, but absolute performance on EgoExo4D zero-shot remains low, indicating that out-of-domain transfer is still challenging.
-
The comparison with large LLM prompting baselines is informative but may not be fully fair. GPT-5.4 Mini and Gemma 4 26B are evaluated using raw numerical IMU (can the authors confirm that?), which are likely weak interfaces for inertial data. These baselines show that generic prompting is insufficient, but they may not be the strongest possible LLM-based alternatives.
-
The contribution of MCQ instruction tuning is somewhat ambiguous. In the ablation, removing MCQ instruction tuning slightly improves Accuracy while reducing F1 and Recall@2. This suggests that the component may help balance recognition or ranking, but it is not clearly beneficial for all metrics. The authors should explain this trade-off and clarify whether this branch is necessary for the final model.
Questions
- Could the authors provide controlled setup-transfer experiments that isolate specific sources of setup variation, such as body placement, sensor orientation, sensor subset, hardware type, and sampling frequency?
- Could the authors provide a more detailed per-dataset failure analysis for zero-shot HAR?
- Could the authors quantify the real-synthetic alignment shown in Figure 6 using embedding-level metrics, such as domain classification accuracy, nearest-neighbor mixing, MMD, silhouette score, or real-to-synthetic retrieval within the same activity?
- Are the LLM prompting baselines strong enough?
- Why does removing MCQ instruction tuning slightly improve Accuracy while reducing F1 and Recall@2?
- What are the main failure modes on EgoExo4D retrieval and captioning, where the absolute performance remains relatively low?
Limitations
The authors are encouraged to create a section for describing all the limitations of their approach.
Paper formatting concerns
No
Final justification
After reading the rebuttal, I am convinced that the paper makes a meaningful and valuable contribution. Overall, the rebuttal significantly improved my confidence in the work, and I support acceptance.
We sincerely thank the reviewer for the thoughtful and constructive feedback and for recognizing several strengths of our work. Below, we respond item by item to the identified weaknesses (W), questions (Q), and limitations (L).
Thank you for this important suggestion. We agree that zeroshot recognition jointly changes multiple factors and therefore does not isolate setup variation. We add controlled paired real-synthetic experiments on Nymeria using the same 1,000 time-aligned windows and 20 sampling seeds. Within each comparison, participant, motion window, activity, and preprocessing are fixed, while only the specified setup factor is changed:
Placement: for every window and visible segment, the synthetic IMU is sampled from a corresponding body-surface candidate vertex; repeated sampling across seeds evaluates within-segment placement variation. Thus, placement variation is already included in the AnyMo row.
Orientation: we apply the additional rotation to each paired real and synthetic IMU: an in-plane rotation around the corresponding surface normal sampled from [-180°,180°] and tilt around the local tangent axes in [-10°,10°].
Sensor subset: on Nymeria, we retain either the head only or the two wrists only while keeping the paired windows and other factors fixed. Our response to R31W W3/L1 additionally reports zero-shot sim-to-real results for 7 subsets covering 17 real sensor locations, including diverse non-head/wrist regions.
Hardware: we replace Nymeria IMU device 1 with its synchronized co-located device 2 with different origin sampling rate while keeping the windows and synthetic signals fixed.
Sampling rate: we downsample the same real and synthetic windows from 60 Hz to 20 Hz and evaluate the separately trained 20 Hz AnyMo pipeline.
We also quantify the Figure 6 comparison using the full model and its simulation/pretraining ablations. All values are mean±std over 20 seeds.
The orientation and hardware controls remain close to the AnyMo reference across all metrics. Head-only and two-wrist inputs reduce activity observability but retain strong paired correspondence, while the 20 Hz pipeline also maintains strong alignment. These controlled results show that the observed robustness is not attributable only to cross-dataset confounds. Quantitatively, removing geometry-aware simulation makes real and synthetic embeddings readily separable, increasing domain-classifier accuracy from 72.8% to 98.0%, reducing kNN mixing from 45.8% to 3.2%, and reducing paired R@1 from 74.7% to 4.7%. Removing masked predictive-contrastive learning appears stronger on domain-only and exact-pair metrics, but these metrics alone do not measure whether the aligned representation preserves motion semantics. The ablation retains pair-specific correspondence but loses activity-level organization: activity silhouette decreases from 0.057 to -0.042, activity purity from 54.1% to 35.8%, and downstream zero-shot HAR from 35.7/29.5/57.5 to 10.5/4.5/19.0. Thus, domain indistinguishability alone is insufficient; AnyMo balances sim-to-real alignment with transferable motion semantics.
Together with the zero-shot CIP–MTwAwinda evaluation in R31W W3/L1, these experiments provide both controlled and quantitative evidence for setup transfer.
Thank you for requesting a more detailed analysis. UniMTS is a strong model supporting recognition and retrieval, while AnyMo is a generalist model that additionally targets open-ended motion captioning. AnyMo achieves the best average on all 3 metrics, and outperforms UniMTS on at least one metric on 12/14 HAR datasets, although it is not uniformly better.
The differences follow three patterns. On w-HAR and USC-HAD, AnyMo has lower Acc./F1 but substantially higher R@2, suggesting that many errors remain among closely related top-ranked alternatives. WISDM and UTD-MHAD are the only datasets where UniMTS leads across all 3 metrics; WISDM uses a wrist sensor, while UTD-MHAD uses a wrist sensor for its first 21 actions and a thigh sensor for the remaining six, indicating that dataset-specific sensing and label definitions still affect zero-shot transfer. Lower absolute results on OpenPack, Ego4D, and MMEA reflect labels involving objects or workflow context that are not always observable from IMU alone, compounded by their larger label vocabularies, particularly the 31 and 32 classes in Ego4D and MMEA. We will add this analysis and avoid claims of uniform per-dataset superiority.
EgoExo4D combines these challenges with head-only sensing and substantial shifts in hardware, mounting, activity distribution, protocol, and narration style. Moreover, exact-pair retrieval counts only the paired window as correct, although multiple windows and captions may describe semantically similar actions. Nevertheless, AnyMo remains strongest in the 100-candidate retrieval setting. The activity-level captioning results reported in our response to TgbB W1/Q2/L1 further show the best overall performance across all five metrics. These results support AnyMo's zero-shot transfer capability while clarifying where sparse sensing and context-dependent labels remain challenging.
Thank you for raising this limitation. AnyMo currently requires one dense motion corpus to construct its synthetic pretraining data, but does not require dense motion supervision from each downstream wearable dataset.
The remaining resources are reusable or modular: anatomical segment definitions and the 23-node graph can be reused across datasets through body-part mapping, atomic-action text is required only for language alignment and can leverage the substantially larger availability of semantic motion-text datasets compared with paired IMU-text datasets; and device-noise priors are optional simulation parameters that can be omitted or replaced with generic priors when calibration streams are unavailable. Our response for reviewer R31W W3/L1 further applies the simulation to independent CIP–MTwAwinda motion and validates alignment at 17 real sensor locations. We will clarify that training from scratch without any dense motion corpus is outside the current scope. Adapting the pipeline to additional representations such as SMPL and studying scaling with additional motion corpora are future work.
Thank you for the question. We confirm that GPT-5.4 Mini and Gemma 4 26B receive raw numerical IMU with sensor-location context. These are not deliberately weak baselines: Gemma 4 26B is the strongest generic LLM and the second-best baseline on average in zero-shot HAR. We additionally provide a trained EgoLM captioning baseline using the same data and training protocol. AnyMo outperforms the adapted EgoLM baseline on all 5 metrics across 2 datasets. Full results are provided in our response to R31W W2/Q3.
Thank you for the question. The original +0.3 Acc. without MCQ was a single-seed fluctuation rather than a consistent improvement. As reported in the response to R31W Q2/Q4/L1, the 3-seed results are 35.6±0.1/28.7±0.5/56.5±0.8 for AnyMo versus 33.4±2.1/26.2±2.2/53.3±1.0 without MCQ. This is a controlled ablation: MCQ rows are replaced with narration rows, preserving all 1,009,770 instruction examples, optimization steps, and other settings. Accuracy is more influenced by frequent classes, whereas macro-F1 measures class-balanced recognition and R@2 evaluates ranking. MCQ exposes explicit competing labels, strengthening inter-class discrimination and balanced ranking. We therefore retain it in the final model.
Thank you for the suggestion. We will add an explicit limitations section to the revised paper.