- Rating
- 5
- Clarity
- 4
- Confidence
- 3
- Originality
- 4
- Quality
- 4
- Significance
- 4
Read review
Summary
This paper introduces how EMG & IMU features could help video action understanding task, they introduced MotorCOdes which is used as to be infused to action understanding task (action reconstruction, hand reconstruction, and video reconstruction), this paper also introduces a new dataset which pair EMG data with egocentric video.
Strengths and weaknesses
Strengths:
- This paper is well written and easy to understand
- Strong, consistent downstream results across diverse benchmarks and tasks
- Showing how EMG+IMU data actually correlate to how human actually works, i.e in Figure 1 shows when hands
- To solve the annotation cost problem, this paper introduces self-supervised representations, Motorcodes are learned entirely from raw EMG via VQ-VAE, and the downstream gains come without any human annotation of the pre-training data.
- The same motor codes serve both as a discriminative pre-training target and as a generative control signal. Demonstrating that one learned representation transfers across recognition, reconstruction, and generation
Weaknesses:
- Motor-code analysis is qualitative. The "codes correlate with action semantics" claim rests on a t-SNE plot. No quantitative measure (clustering purity, MI, or a code→action linear probe)
- Incomplete isolation of the EMG contribution. The IMU ablation helps, but there is no continued video-only self-supervised pre-training baseline on motorsense. Without it, "motor codes help" is partly confounded with "more in-domain egocentric video helps." an ablation on reconstruction would be better since IMU help with the position a lot.
Questions
- "we use a per-vertex threshold of 10% as opposed to 5%", mentioned in page 8, Why the 10% ARCTIC threshold? What are the numbers at the standard 5%?
- Any sensitivity analysis for codebook size (N=64), code rate (64/s), and window length (1.5s)?
Limitations
yes
Paper formatting concerns
none
We thank the reviewer for the thoughtful and positive assessment of our work. We appreciate the observation that motor codes provide a useful embodied signal for many downstream tasks in computer vision. The reviewer’s main concerns focus on whether the semantic structure of the codes can be demonstrated quantitatively and whether the gains can be separated from the effect of additional in-domain video pre-training. We have addressed both points through new experiments.
We agree that the original t-SNE visualization was insufficient. We fit a K-means clustering model over the labeled motor-code representations, with the number of clusters set by the number of actions under evaluation. For each value of k, we select the k most frequent annotated actions and fit k clusters over the frozen motor-code representations without using labels. We then label each cluster using the ground-truth label of the sample closest to its centroid and assign that label to the remaining samples in the cluster. Thus, labels are used only to name each learned cluster, using one labeled exemplar per cluster. The results are encouraging given that only one labeled exemplar per cluster is used.
\hline \text{k} & \text{Verb} & \text{Noun} & \text{Action} \\\\ \hline 2 & 1.000 & 1.000 & 1.000 \\\\ 3 & 0.645 & 1.000 & 0.645 \\\\ 4 & 0.711 & 0.711 & 0.526 \\\\ 5 & 0.721 & 0.651 & 0.512 \\\\ 6 & 0.688 & 0.542 & 0.438 \\\\ 7 & 0.717 & 0.491 & 0.453 \\\\ 8 & 0.684 & 0.439 & 0.421 \\\\ 9 & 0.650 & 0.450 & 0.417 \\\\ 10 & 0.540 & 0.571 & 0.429 \\\\ \hline \end{array}$$ 2. Representation ablations We agree that an in-domain visual baseline is necessary to distinguish the value of motor-code supervision from the value of simply continuing pre-training on egocentric video. We therefore train CVRL using the same MOTORSENSE clips, Hiera backbone, K400 initialization, hand-focused cropping, and downstream fine-tuning protocol used for motor-code pre-training. We also expand the ablation to compare raw continuous EMG, discrete EMG-only codes, histogram aggregation, Aria MPS hand-pose supervision, and alternative EMG+IMU objectives. $$\begin{array}{lccc} \hline \text{Pre-training configuration} & \text{EPIC verb} & \text{EPIC noun} & \text{Meccano action} \\\\ \hline \text{K400 initialization only} & 41.65 & 15.12 & 26.42 \\\\ \text{Vision-only (CVRL) [1]} & 41.01 & 19.31 & 28.99 \\\\ \text{Pose (no VQ-VAE)} & 46.92 & 20.10 & 31.50 \\\\ \text{Pose (VQ-VAE + histogram)} & 43.29 & 15.90 & 26.05 \\\\ \text{EMG-only (raw)} & 42.23 & 14.99 & 26.62 \\\\ \text{EMG-only (VQ-VAE)} & 46.01 & 16.38 & 27.29 \\\\ \text{EMG-only (VQ-VAE + histogram)} & 48.59 & 20.99 & 33.36 \\\\ \text{EMG + IMU (no VQ-VAE)} & 45.86 & 19.72 & 31.76 \\\\ \text{EMG + IMU (VQ-VAE)} & 49.20 & 20.22 & 36.15 \\\\ \text{EMG + IMU (ours)} & \mathbf{52.64} & \mathbf{22.23} & \mathbf{37.32} \\\\ \hline \end{array}$$ $$\begin{array}{llcc} \hline \text{Method} & \text{Pre-training} & \text{MPJPE}\downarrow & \text{Success@5\\%}\uparrow \\\\ \hline \text{ARCTIC} & \text{IN} & 25.41 & 50.26 \\\\ \text{PixPro} & \text{IN} & 24.69 & 51.63 \\\\ \text{DenseCL} & \text{COCO + IN} & 27.33 & 48.82 \\\\ \text{SimHand} & \text{100DOH + Ego4D} & 34.94 & 41.90 \\\\ \text{PeCLR} & \text{100DOH + Ego4D} & 28.82 & 45.03 \\\\ \text{DenseCL} & \text{IN + MotorSense (RGB)} & 28.89 & 49.83 \\\\ \text{VICRegL} & \text{IN + MotorSense (RGB)} & 27.81 & 48.10 \\\\ \text{Ours} & \text{IN + MotorSense} & \mathbf{23.59} & \mathbf{55.03} \\\\ \hline \end{array}$$ 3. Sensitivity to codebook size, code rate, and window length These experiments are interesting, as it is expected these factors should have a large influence on the performance of the motor code predictor, and therefore downstream impact. Surprisingly, we do not observe this to be the case for codebook size and window length (and observe minor changes varying codes per second). Once all the runs complete we will report them here.