- Rating
- 4
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 4
- Significance
- 3
Read review
Summary
The paper presents NiSM, a neuro-inspired structured model for estimating five-finger contact pressure from sparse wearable sensing. Using a self-designed ring-watch platform with a thumb-mounted IMU and a single-channel wrist EMG sensor, the work aims to reduce reliance on dense sensing systems such as multi-channel EMG arrays, data gloves, or pressure sensor arrays. NiSM incorporates IMU-derived grasp context, sparse kinematic coupling, and EMG-conditioned effort scaling to predict finger-level pressure from limited sensor inputs. Experiments on a self-collected multi-user, multi-object dataset and a sparse-view setting of the PiMForce benchmark suggest that the proposed structured model outperforms several generic sparse-input baselines and approaches dense-sensing references in the reported setting.
Strengths and weaknesses
Strengths:
-
The paper is well motivated and addresses a practically meaningful problem: estimating finger-level contact pressure from sparse wearable sensing, where dense sensing systems such as multi-channel EMG arrays, data gloves, or pressure arrays are often impractical for everyday use. The proposed architecture is coherent with this motivation, as the IMU-derived grasp context, sparse kinematic coupling, and EMG-conditioned effort scaling each target a specific information gap under sparse sensing.
-
I also appreciate the system-level effort. The authors design a wearable ring-watch sensing platform and collect a multi-user, multi-action dataset with synchronized IMU, EMG, and finger-force measurements, which strengthens the practical relevance of the work. The experiments and ablations support the effectiveness of the structured components, and the additional evaluation on PiMForce suggests a degree of architecture-level transferability, although this is based on re-training rather than direct cross-dataset generalization.
Weaknesses.
-
Limited physical grounding of the structured model. The proposed structure is mainly architectural rather than physically or biomechanically grounded. Although the model assigns meaningful roles to IMU-derived context, sparse kinematic coupling, and EMG-conditioned scaling, it does not explicitly incorporate IMU kinematics, sensor-to-hand calibration, hand joint constraints, or contact/force-generation mechanics. This makes the “neuro-biomechanical” motivation somewhat stronger than what is actually implemented.
-
Insufficient robustness analysis for wearable sensor placement. Since the IMU is embedded in a ring-like device, the input signals may be sensitive to placement variations, including finger choice, wearing depth, rotational offsets, and repeated donning/doffing. The paper does not sufficiently evaluate whether the learned model remains stable under such practical variations, which weakens the deployment claim.
-
Fairness and interpretation of dense-sensing comparisons. The comparison with dense-sensing references is not fully controlled, since NiSM and the dense baseline differ in input modalities, model architecture, parameter count, and output mapping. In addition, the PiMForce evaluation is based on re-training under a sparse-view setting, so it supports architecture-level applicability but does not demonstrate direct cross-dataset or cross-hardware generalization.
Questions
See weaknesses.
Limitations
Yes
Paper formatting concerns
None
Final justification
I think the author's response addressed most of my questions and believe this article meets the acceptance bar.
We thank the reviewer for the constructive feedback. We have addressed each weakness in the corresponding point-wise responses.
We provide (i) revised terminology and claims that scope our contribution to architecture-level structure rather than implemented biomechanics, (ii) a clarification of our donning protocol together with a narrowed deployment claim, and (iii) paired significance tests and baseline tuning details for the dense-sensing comparison.
We hope these clarifications effectively address the reviewer's concerns and further strengthen the paper.
W1. The structured model is architectural rather than physically or biomechanically grounded.
On terminology and claim scope. We agree, and we think the reviewer has identified the correct boundary of our contribution. NiSM does not solve forward kinematics, model tendon routing, perform sensor-to-hand calibration, or simulate contact mechanics. We will replace "neuro-biomechanically structured" with "neuro-inspired structured" throughout, present the biological account in the Abstract and Section 1 as an analogy motivating the architecture rather than an implemented model, and rewrite Section 2.3 to position our work relative to biomechanical models instead of among them.
On the motivation of specific design choices. Although NiSM is not a biomechanical model, several design choices are physically motivated: (1) we represent thumb orientation using a full rotation matrix, which avoids Euler-angle singularities and discontinuities. (2) RMS, and waveform-length features provide effort-related summaries of the single-channel sEMG signal; we do not interpret them as direct measurements of motor-unit recruitment. Accordingly, EMG is used as a learned modulation of a kinematically conditioned base prediction. Third, Eq. 6 encodes an approximate separability assumption: grasp context and thumb kinematics determine a finger-wise pressure pattern, while EMG modulates its magnitude. These choices should be understood as physically motivated inductive biases, supported empirically by our ablations.
On the path forward. Incorporating joint constraints, tendon-coupling priors, and contact mechanics is the promising next step, and we will frame it as substantial future work in the revised limitations.
W2. Insufficient robustness analysis for wearable sensor placement.
On the donning protocol. We should have made an important property of our collection explicit: we used no mounting fixture and gave no instruction on ring orientation, rotational alignment, or wearing depth. Each of the 20 participants donned the ring themselves and adjusted it for comfort, as they would in everyday use. The mounting configuration therefore varies freely across participants along exactly the axes the reviewer lists, and our data span this variation by construction rather than being collected under a canonical mount. We will state this in Section 3.1 and Appendix A.1.1.
On scope. We are careful not to overstate what this establishes. It speaks to the naturally occurring distribution of self-donned placements, which is bounded by comfort and ring geometry. It does not characterize arbitrary or adversarial offsets (e.g., a deliberate 45° rotation), and it does not cover repeated donning/doffing by the same participant, since each session was completed in a single donning. Within-user re-mounting repeatability is genuinely untested, and we agree with the reviewer that this is a gap.
On finger choice. The ring is thumb-mounted by design rather than by convenience: the thumb participates in nearly all grasp types and provides the opposition reference against which the other fingers act, so its kinematics carry disproportionate information about the global grasp configuration — the premise of the grasp-context pathway in Section 3.2. Mounting the ring on another finger is a different sensing configuration, not a placement perturbation, and is outside the intended deployment. We will make this explicit.
On the deployment claim. We accept the reviewer's core point that our claim outran our evidence, and will condition it on what was actually validated: operation under naturalistic self-donning, with systematic characterization under controlled rotational offsets, varying wearing depth, and repeated donning/doffing stated as open. We commit to a controlled placement study, including a test-time rotational-offset sweep and a within-user re-donning session, for the camera-ready.
W3. Fairness and interpretation of the dense-sensing comparison.
On claim revision. We adopt the reviewer's framing, which we believe is the correct characterization. We will state that the PiMForce evaluation demonstrates architecture-level applicability under a sparse-view setting and does not demonstrate cross-dataset or cross-hardware generalization, since the model is retrained rather than transferred. "Structure substitutes for sensing" is removed from the Abstract, Section 1, and Section 6, and replaced with the narrower claim that structural priors partially recover force-relevant information within a given dataset and sensing configuration.
On baseline tuning. We agree an undertuned dense reference would invalidate the comparison. PiMForce-dense was [retained at its published hyperparameters with an additional sweep over {lr, batch size}], selected under the same criterion as NiSM. We will report the tuning budget of every model in the appendix so this can be judged directly.
We are grateful for the reviewer's recognition of the system-level and dataset contributions, and hope the protocol clarification and narrowed claims address the concerns raised.