- Rating
- 4
- Clarity
- 2
- Confidence
- 4
- Originality
- 3
- Quality
- 2
- Significance
- 3
Read review
Summary
This work argues that the inertia matrix can provide a useful representation for analyzing the gait kinematics of Parkinson's disease (PD) patients. Concretely, it
- claims that gait phenotyping is a more useful objective than reconstruction quality, and proposes REINS, a model fine-tuned from PhysPT
- demonstrates that REINS enables more meaningful analysis on a PD gait benchmark.
Strengths and weaknesses
Strengths
- The core idea is principled and elegant. Using the inertia matrix as the geometry of the representation itself, rather than as a post-hoc penalty on reconstruction, is a fresh framing. The derivation of a Riemannian metric from the fact that kinetic energy is a quadratic form in velocity, , is mechanically grounded and convincing.
- The empirical gap is large and consistent. In Table 1, the jump from the Euclidean baselines (0.52–0.61) to the geodesic distance (0.87–0.90) is effectively a leap from near-chance to strong discrimination, and the data efficiency in Table 2 (retaining 0.76 AUROC down to K=1) has real value in the clinical data-scarcity regime.
- The zero-shot transfer results support the central claim. Without per-cohort calibration, the UPDRS correlations are positive across all four heterogeneous cohorts (PD-GaM, BMCLab, T-SDU-PD, 3DGait) and substantially exceed the Euclidean baselines (Table 3), which is consistent with the hypothesis that a mechanical prior is invariant to site/protocol.
Weaknesses
Major
- The central claim (reorganization of the latent space) is supported only by indirect evidence. The narrative centers on the structure of the latent space, but the experimental results (improved AUROC) do not separate whether the gain comes from (i) a structural reorganization of the latent space, (ii) changing the distance from a raw Euclidean distance in the latent to an inertia-induced geodesic, or (iii) simply the pullback through the decoder Jacobian . Supporting the claim requires direct evidence that disentangles these factors (see the 3×2 ablation in Question 3). This is the decisive reason the review leans toward rejection.
- Statistical rigor is lacking for a clinical paper. No confidence intervals are provided for key metrics such as AUROC (Tables 1, 2). It is not stated which test the significance in Table 3 refers to. Moreover, four entries in Table 2 (data-driven K=1; physics-supervised K=5/K=3/K=1) have AUROC below chance (0.5), and this is not adequately explained. For the credibility of a clinical claim, variance estimates (e.g., k-fold) and confidence intervals are needed.
Moderate
- Engagement with the motion-prior representation literature is thin. Since this work proposes a motion representation, it should be deeply grounded in the motion-prior literature. However, it relies on a single backbone (PhysPT), and comparison with / discussion of the broad body of prior work on human motion prior representations themselves (e.g., latent motion models such as VPoser, HuMoR, and motion-VAE-style methods) is missing. The bibliography is also sparse overall (17 references in total). (WHAM [13] and SimPoE [15] use priors to solve downstream tasks rather than studying the structure of the representation itself, so they do not substitute for this grounding.)
Minor
- For readability, abbreviations should be spelled out before use. Terms like PD and HC are not commonly used at venues like NeurIPS and should be defined in advance. The same applies to manual abbreviations such as EL.
- LaTeX references are broken at lines 150 and 174 ("Section ??").
- Line 38–39, "unexplored.Such" a space is missing between the sentences.
Questions
- If there is a reason for choosing PhysPT among the many motion priors, please explain. In Tables 1 and 2, physics-supervised performs worse than data-driven in most settings. if so, I am curious why the pretrained model was not chosen to be purely data-driven.
- Please explain how the normal reference distribution at line 173 is computed. I could not find the relevant details in the text. My guess is that at K=1 in Table 2, only the z-values of the training subject(s) are used... is my understanding correct? If so, at K=1 the AUROC would seem to swing greatly depending on which subject is selected.
- To fairly isolate the role of the mass matrix , a 3×2 comparison of (3 distances) × (2 fine-tuning conditions) is needed. Currently in Table 1 the Euclidean baseline is measured as a raw Euclidean distance in the latent , while ours is measured as a geodesic distance under the pullback metric , so it is not separated whether the improvement is due to (i) or (ii) simply the pullback through the decoder Jacobian .
- Distance (3): (a) Euclidean: raw Euclidean distance in the latent (b) geodesic: pullback distance with (reflecting only the decoder Jacobian) (c) geodesic: full inertia metric (ours).
- Fine-tuning (2): (1) without , and (2) with (REINS).
- This isolates each factor: (a)/(b) is the net effect of the pullback through (b)/(c) is the net contribution of the mass matrix (on the same pullback footing, vs. ) and (1)/(2) is the latent restructuring effect from . As reported, only some of these cells are shown, so the effect of , the effect of , and the change in latent structure are confounded.
- I do not understand why four entries in Table 2 have AUROC below the random-label value of 0.5. Please perform k-fold validation on Tables 1 and 2 and provide confidence intervals. With confidence intervals, there may be room to make sense of this.
Limitations
It would be very meaningful to verify whether the proposed logic applies across a variety of motion priors. Also, from a dynamics standpoint only the mass matrix is analyzed. From a biomechanics standpoint, it would be worth analyzing the muscle Jacobian as well. That is, analyzing the operating range of the muscles.
Paper formatting concerns
None
Final justification
I update my score to 4: Borderline Accept.
The rebuttal resolved my main concerns. The new 3×2 ablation separates the effects of the representation, decoder pullback, and inertia matrix. The added confidence intervals and split results also address the statistical concerns.
The authors clarified the reference construction, the (K=1) setting, the choice of PhysPT, and the external baseline protocol.
Some limitations remain. The evaluation is still based on a limited number of motion priors and datasets, so the generality of the method is not fully established. However, I do not consider these issues strong enough to reject the paper.
Overall, the main technical concerns were addressed, while the remaining issues mainly affect the strength of the acceptance rather than the validity of the contribution.
We thank Reviewer 2Efi for the careful reading and for the specific, actionable suggestions. We respond to each point below.
Subject-level HC vs PD AUROC at K=20 (95% CI).
Table 1*: main setting over several random subject splits and report mean ± sd
About Table 3: the asterisks mark p < 0.05 against the null of zero rank correlation. The p-values are those returned by scipy’s spearmanr and kendalltau (τ-b). The unit is the subject, so n is the number of subjects in each cohort, as given in the table header. We add this to the caption.
About the four below-chance entries: With 8 HC and 30 PD subjects, an uninformative score has a 95% range of roughly [0.28, 0.72], so values in the 0.43-0.48 range are not separable from chance. Their bootstrap intervals include 0.5. We report these intervals in the revised Tables 1 and 2.
External baselines for Anomaly detection AUROC at K=20 HC training subjects
Abbreviations (Responding to Minor Weakness 1) We will spell out Parkinson’s Disease, Health Control, Euler-Lagrange and any abbreviations that may have caused confusion and ambiguouty
Broken Cross-reference (Responding to Minor Weakness 2) The two broken references at lines 150 and 174 should have pointed to Sec 3.4 (Learning a Latent Embedding). We will fix them
Missing Space (Responding to Minor Weakness 3) We will add the missing space at line 38
Choice of PhysPT as a backbone (Responding to Question 1) About the choice of backbone: Our starting point is that the representation should carry physical structure, and PhysPT is the pretrained monocular model whose objective already contains force, contact and Euler-Lagrange terms. The motion priors in the literature we are aware of, including VPoser and HuMoR, are kinematic. Starting from PhysPT is what makes the comparison in this paper possible, which moves physics from a trajectory-level penalty into the geometry of the representation, and conditions D and F differ exactly by that substitution.
About physics-supervised performing worse and the choice of pretrained model: All conditions start from the same AMASS-pretrained PhysPT checkpoint and differ only in the fine-tuning objective. Condition C is the purely data-driven fine-tuning, and it is reported. So Condition C > Condition D is because of the fine-tuning loss instead of the pretraining. We have not tested a purely data-driven pretrained backbone.
The two readouts use those windows differently. For the Euclidean readout, μ_N is their sample mean, with covariance estimated by Ledoit-Wolf shrinkage. For the geodesic readout there is no single reference point: every training-HC window is a source in the k-NN graph, and a window's score is the shortest-path length to the nearest of them. The notation at line 173 describes the Euclidean case, and we will make the geodesic case explicit in Sec 3.5.
When K = 1 the single training subject is fixed by the split seed, so the result does depend on which subject is drawn. The multiple-split runs reported in A4 quantify how much it varies.
Generality across motion priors (Responding to Limitations) We agree on both and add them to the Limitations. About motion priors, we are adding one external backbone under our protocol (see R3) and note that a systematic check across priors remains open.
The muscle Jacobian (Responding to Limitations) About the muscle Jacobian: a musculoskeletal model with muscle paths and activation estimates is needed, which in practice requires EMG, while CARE-PD provides pose only, so we cannot evaluate it on this benchmark.