Strengths
This paper tackles a genuinely underserved problem in medical imaging: cross-modal transfer between fetal MRI and fetal ultrasound in a setting where subject-level paired acquisitions are fundamentally unavailable, not merely scarce. Unlike the bulk of multimodal medical imaging work that integrates sequences within the same imaging category (e.g., T1, T2, FLAIR), this work confronts the harder problem of bridging entirely different sensing modalities under data imbalance and structural unpairedness — a setting that closely mirrors real clinical data availability constraints. The framework's design is also practically appealing: by learning a lightweight alignment layer on top of frozen pretrained backbones, WASP allows existing US foundation models to be reused directly without any backbone fine-tuning, which is attractive both computationally and in terms of reproducibility.
Methodologically, the core idea of converting routinely recorded clinical metadata — gestational age and standard diagnostic plane — into a cost function for entropic Optimal Transport is a sensible and domain-appropriate design choice. Rather than treating the two modalities as exchangeable point clouds, as is common in generic unpaired representation learning (e.g., CORAL, adversarial alignment), WASP encodes a biologically grounded prior: that fetal anatomy at a given developmental stage and diagnostic plane is consistent across subjects. This is a meaningful instantiation of clinical prior knowledge within the alignment objective itself, rather than as an auxiliary or post-hoc adjustment.
Weaknesses
Quality.
The central methodological claim — that entropic OT with spatiotemporal metadata cost outperforms alternative pairing strategies — is not fully isolated by the experimental design. The ablation in Table 3 examines the contribution of each cost term (Dtime,
Dembed, Dspace), but the paper never compares against a metadata-free OT baseline (i.e., entropic OT using only raw embedding distance, without GA or plane information). Without this comparison, it remains unclear how much of WASP's advantage over Hungarian/Greedy matching stems from the entropic relaxation itself versus the metadata-driven cost design — both of which are presented as joint contributions but are never independently ablated against each other directly. Additionally, the paper explicitly identifies MRI-CORE [16] in the related work as the most relevant recent MRI-specific generalist backbone, yet this backbone is absent from all experiments in Tables 1, 2, and 4. Given that the authors themselves flag it as the closest point of comparison, its exclusion is a notable gap in experimental completeness.
Clarity.
The method section (Sec. 3.1) is well organized and walks through the construction of the cost matrix, the rationale for entropic regularization over standard OT, and the necessity of row-normalization in the barycentric projection step with appropriate intuition at each stage. Figure 1 effectively communicates the two-phase structure of the framework. The writing is generally precise, though there is some redundancy in the results tables (e.g., the WASP row in Table 1 is repeated identically in Table 4), and the evaluation protocol description in Sec. 4.1 contains a duplicated sentence regarding the combined hyperparameter selection metric.
Significance.
The problem setting is clinically relevant and the asymmetry between US and MRI data availability is a real and underexplored bottleneck. However, the narrow baseline comparison makes it difficult to assess how significant the proposed gains are relative to the broader landscape of unpaired cross-modal alignment techniques. The related work section explicitly discusses cycle-consistency-based image translation and adversarial latent alignment as established families of approaches for this exact problem (unpaired multimodal representation learning), yet neither family is included as an experimental baseline. Likewise, Gromov-Wasserstein-style OT, which preserves intra-domain structure and is commonly used in unpaired cross-domain settings, is not considered as an alternative OT formulation. Without these comparisons, it is hard to gauge whether WASP represents a meaningful advance over the broader toolkit available for this problem, or whether it is simply the strongest among a self-selected set of relatively weak baselines (Random, Cosine, Hungarian, Greedy).
Originality.
The core idea of encoding routinely available clinical metadata directly into an Optimal Transport cost function, rather than relying on raw feature-space proximity or generative translation, is a novel and well-motivated adaptation to the fetal imaging domain. The combination of temporal (GA), spatial (plane), and embedding-prototype costs is a thoughtful design that reflects genuine understanding of fetal neurodevelopmental regularities (and is further supported by the biological grounding discussion in Appendix E). That said, the individual algorithmic components — entropic OT, Sinkhorn-Knopp, barycentric projection — are all established techniques, and the contribution lies primarily in their application and cost design rather than in a new transport or alignment formulation.
We thank the reviewer for their constructive feedback. We appreciate their recognition of the novelty of the proposed cross-modal alignment framework, the comprehensive experimental evaluation across multiple scenarios and backbones, and the promising empirical performance of WASP. We respond to specific questions and concerns below.
Motivations for multimodal US and MRI models (Q1)
We thank the reviewer for the observation. We agree that gestational-age estimation and standard-plane identification are primarily ultrasound tasks in routine clinical practice, and we do not intend to suggest that fetal MRI should replace ultrasound for these purposes. We instead believe that the main contribution of WASP is not an MRI GA-estimator, but rather that it is a recipe for building metadata-paired multimodal datasets from independent cohorts using commonly available metadata that hospitals already record. Thus, we deliberately chose these two particular tasks as they both provide well-defined labels that are available across ultrasound and MRI cohorts. In these settings, performance on the chosen tasks are intended to measure the quality and semantic preservation of the learned alignment, rather than to motivate a new clinical workflow based on MRI.
Upper-bound performance on downstream tasks (Q2)
We thank the reviewer for the suggestion. We provide the results of directly finetuned models on MRI data. We did not provide this baseline in the paper as we believe it addresses a different problem and scenario since our intent is to tackle cases in which very few samples of either MRI or US are available (especially the former), with none of them being paired with the other modality.
Direct MRI fine-tuning as an upper-bound reference:
As these results indicate, directly finetuning on the other modality still yields substantial improvements over the baselines. At the same time, WASP remains competitive while keeping the backbone frozen. This highlights the key trade-off: direct fine-tuning can improve target-domain performance, whereas WASP enables cross-modal adaptation without modifying the pretrained representation.
Because fine-tuning updates the shared backbone, target-domain gains alone are not sufficient in a multimodal setting. We therefore also evaluated source-domain performance after adaptation to assess whether the original representation was disrupted.
Source domain forgetting in multimodal settings:
MRI fine-tuning consistently degrades source-domain GA performance and can also reduce classification performance, showing that target-domain adaptation may disrupt the original representation. WASP avoids this issue by keeping the backbone frozen and preserving the source-domain capabilities by construction.
We will include both the MRI upper-bound results and this source-domain preservation analysis in the revision.
Scale of US dataset (Q3)
We thank the reviewer for this observation. FETAL_PLANES_DB is already included in our US cohort, but this was not stated clearly enough in the submission.
Our US dataset is based on the multi-centre, multi-device benchmark [1], which aggregates data from FETAL_PLANES_DB [2], the head-circumference dataset [3], and an expanded UCLH cohort [4]. In addition, because the benchmark does not include all non-transthalamic images available in FETAL_PLANES_DB, we directly incorporated the remaining TV and TC images from FETAL_PLANES_DB to improve coverage of these planes.
Therefore, the dataset suggested by the reviewer is not an additional unexplored source, and incorporating it would not increase the current cohort. We will revise the dataset description to make this composition explicit. We agree that studying WASP contribution as a function of dataset size remains valuable; this would require either controlled subsampling or additional independent public US datasets with compatible plane annotations and metadata, which, to the best of our knowledge, are not currently available. We will identify this analysis as future work.
References
[1] Di Vece, Chiara, et al. "A multi-centre, multi-device benchmark dataset for landmark-based comprehensive fetal biometry." arXiv preprint arXiv:2512.16710 (2025).
[2] Burgos-Artizzu, X.P., et al. Evaluation of deep convolutional neural networks for automatic classification of common maternal fetal ultrasound planes. Sci Rep 10, 10200 (2020).
[3] Thomas LA van den Heuvel, Dagmar de Bruijn, Chris L de Korte, and Bram van Ginneken. Automated measurement of fetal head circumference using 2d ultrasound images. PloS one, 13(8):e0200412, 2018.
[4] Sophia Bano, Brian Dromey, Francisco Vasconcelos, Raffaele Napolitano, Anna L David, Donald M398 Peebles, and Danail Stoyanov. Autofb: automating fetal biometry estimation from standard ultrasound399 planes. In International Conference on Medical Image Computing and Computer-Assisted Intervention, pages 228–238. Springer, 2021.