Summary
This paper addresses test-time adaptation in medical VLMs. The authors assume that medical VLMs are often adapted on high-quality images but later deployed on lower-quality ones from different scanners, protocols, or reconstructions. This changes how images look without changing the clinical question, and it can cause the adapted model to fail. They propose ASSET, which applies acquisition-like proxy transformations to target examples and measures how sensitive the model's predictions are to them. From this sensitivity, it estimates a small parameter subspace responsible for acquisition-shift failures, and restricts adaptation to update only within that subspace. The proposed method has been evaluated across three medical VQA benchmarks (SLAKE, RadImageNet-VQA, GMAI-MMBench) and two backbones (InternVL3.5-8B, MedGemma-4B-IT).
Strengths and weaknesses
Strengths
Rather than just saying that acquisition-quality shift matters, the authors first demonstrate it. They show empirically that such shifts systematically degrade accuracy, and that naively fine-tuning on a small labeled target support set entangles genuine correction with harmful drift. The problem is realistic and well-scoped. The evaluation is broad and the central claim is properly validated. The paper is well-structured and well organised.
Weaknesses
The performance gains are modest and, more importantly, non-uniform in a way the aggregate numbers obscure. The abstract's +2.62 on average / +4.12 on the strongest shift is quite small. Table 1 shows that the advantage is concentrated on RadImageNet while largely vanishing on others. And the paper does not analyze why different datasets behaves differently. Another concern is that the medical evaluation rests entirely on physics-inspired synthetic degradations rather than real paired reference-quality and degraded acquisitions. A more fundamental concern is the paper's core directional assumption. The problem is formalized as correcting a model adapted on a high-quality source condition when deployed on a strictly lower-quality target condition, and synthetic shift family is a degradation layered on clean images. This high-to-low ordering is asserted rather than justified, yet real medical deployment may violates it: models are trained on large, heterogeneous, mixed-quality multi-site data and then deployed at a single higher-quality site, or the source and target differ in kind rather than along a clean quality axis.
Questions
-
Why does the proposed method underperform on SLAKE and GMAI, and what does this imply about when the method helps? In Table 1, ASSET trails MEMO on GMAI average (50.9 vs 51.4) and Tent on GMAI strongest-shift (40.0 vs 40.3). Similarly, the preformance on SLAKE is around 0.2-0.4%. A convincing analysis could help readers to understand if the benefit is intrinsically dataset-dependent.
-
How does ASSET behave on real paired clinical acquisitions rather than synthetic degradations? The medical results rely on CT/MRI/VAE synthetic degradations, which the conclusion flags as a limitation. Even a small pilot on a single real paired dataset (e.g., low-dose vs standard-dose CT, or differing reconstruction pipelines) would directly test whether the synthetic-to-real gap preserves the reported gains.
-
Can the contribution of the per-round iteration be isolated from the subspace constraint itself? Figure 5a shows accuracy improving over rounds, but it is not clear how much of ASSET's advantage comes from the iterative re-estimation versus a single subspace-constrained update. An ablation comparing one-round ASSET to the full iterative version (and to an unconstrained update run for the same number of steps) would help attribute the gains correctly and clarify the cost/benefit of the loop, which currently adds the most computational overhead.
-
Does ASSET generalize beyond the high-quality-source to low-quality-target direction? As noted in the weaknesses, the formulation and all synthetic shifts assume a high-quality source and a lower-quality target, and the ASSET appears specialized to this assumed direction. Could the authors discuss the generalisability?
Limitations
Partially. The authors do address limitations, but the discussion is thin relative to the scope of the work.
Paper formatting concerns
No formating concerns.
Final justification
Thanks the authors for the detailed rebuttal. The rebuttal has addressed most of my concerns, so I maintain the score.
We're glad that the reviewer found the problem realistic and well scoped, our evaluation broad, and the central claim properly validated. We respond to the reviewer's concerns and questions point by point below.
[Con 1 & Q1. Magnitude and dataset heterogeneity of the gains?] We do not think the overall improvement is appropriately characterized as small. The relevant comparison is whether one method improves already source-adapted medical VLMs over the strongest alternatives across the complete evaluation. ASSET is evaluated over 30 backbone–dataset–shift combinations, including mild conditions where the source model is already near ceiling and little acquisition-induced error remains to correct. It nevertheless achieves the best overall shifted accuracy, with the advantage becoming larger under the strongest shifts.
The overall result summarizes the complete grid, while the main-results table in the paper reports every dataset separately. The variation across datasets identifies when acquisition-sensitive adaptation has more error to correct. On RadImageNet-VQA, the source-adapted model is near ceiling on clean images (96.3), but falls to 71.8 on shifted images, so most of the new error is induced by acquisition degradation. SLAKE has a much smaller clean-to-shift drop (88.1 to 79.0). GMAI-MMBench begins at 72.7 even on clean images, so a substantial part of its error comes from heterogeneous anatomy and diagnosis questions that acquisition correction is not intended to repair. ASSET therefore helps most when acquisition variation accounts for a substantial share of the deployed model's error.
The question cites MEMO as 51.4 on GMAI-MMBench, but the main-results table reports 51.1 for MEMO. The 51.4 result belongs to ZERO. More importantly, no competing method dominates ASSET on both GMAI shifted metrics: ZERO obtains 51.4/39.8 for Avg./Strongest, Tent obtains 50.6/40.3, and ASSET obtains 50.9/40.0. On SLAKE, ASSET achieves the best Avg. and Strongest results, 79.6 and 73.9. We further repeat the complete five-family evaluation over five support/reference splits with InternVL3.5-8B:
The paired intervals remain above zero on both datasets. The smaller non-RadImageNet gains reflect a smaller acquisition-specific share of their total error, and they do not disappear as the calibration examples change.
[Con 2 & Q2. Real clinical acquisition-shift evidence?] We complement the controlled medical stress tests with a native clinical acquisition-protocol evaluation. We use the recorded acquisition views in MIMIC-CXR-VQA to construct this real protocol shift. Posteroanterior (PA) radiographs form the source condition and anteroposterior (AP) radiographs form the target condition. These views reverse the X-ray projection direction relative to the patient, changing acquisition geometry and image appearance. We adapt InternVL3.5-8B with 32 labeled AP support examples and 32 PA reference examples, then evaluate on 782 held-out AP and 146 held-out PA questions. Results are averaged over three calibration draws. ASSET w/o subspace uses the same calibration examples and losses but updates all trainable adapter parameters directly.
ASSET transfers the correction from 32 AP support examples to held-out AP questions while maintaining accuracy under the original PA protocol. The unconstrained control receives the same calibration information, yet does not improve AP and causes substantial PA drift. The evaluation uses native clinical acquisitions, and the proxy bank contains no view-position or projection-reversal operation. The result shows that ASSET can adapt to a real clinical acquisition change outside the five controlled degradation families.
[Q3. Contribution and cost of iterative re-estimation?] Our results show that iterative re-estimation contributes beyond both the subspace constraint and the number of optimization updates. We compare matched variants on MedGemma-4B-IT and SLAKE under CT-Gaussian shifts. All use the same 32 target and 32 reference examples, losses, and 40 updates. One-round ASSET performs all updates after a single estimate, fixed one-shot keeps its initial subspace across rounds, full ASSET re-estimates it each round, and ASSET w/o subspace removes the constraint.
Full ASSET exceeds both one-round and fixed one-shot ASSET, showing that its advantage is not explained by performing more updates or merely estimating one useful low-dimensional basis. The much larger gap over the unconstrained control separately establishes the value of restricting adaptation to acquisition-sensitive directions.
In our end-to-end profiling on one NVIDIA RTX 6000 Ada GPU, fixed one-shot requires 159.22 seconds and full ASSET requires 247.91 seconds. This additional computation is a one-time calibration cost for a new acquisition condition. After adaptation, ASSET uses the same VLM architecture without per-example optimization or additional inference modules.
[Q4. Generalization beyond high-quality source to lower-quality target?] We want to clarify that high-to-low deployment is the concrete and practically important acquisition-shift scenario studied in the paper, while ASSET's adaptation rule is defined by source and target distributions rather than their relative image quality. ASSET adapts a model from its source distribution to the deployment distribution represented by target support, while preserving behavior on the source. In our formulation, the source distribution is the condition used to train the source-specific LoRA adapter, even when the foundation model was pretrained on mixed-quality, multi-site data. The same formulation therefore applies when the target site has higher image quality.
Proxy views serve as sensitivity probes, so they do not require the target condition to follow the same degradation direction. Our MIMIC-CXR-VQA experiment provides a concrete example. PA and AP differ in projection geometry, the proxy bank contains no corresponding transformation, and ASSET still improves AP by 2.98 while retaining PA accuracy. ASSET is therefore directional in the usual adaptation sense of moving from a designated source distribution to a designated target distribution, rather than being specialized to decreasing image quality.