- Rating
- 4
- Clarity
- 2
- Confidence
- 5
- Originality
- 2
- Quality
- 2
- Significance
- 3
Read review
Summary
This paper proposes WsiSSM, a weakly supervised subset-matching framework for unified classification and segmentation of histopathology whole-slide images. The method introduces a Sparse-CAM backbone that combines sparse self-attention with CAM generation, aiming to improve both slide-level classification and weakly supervised localization. In addition, the paper proposes a subset-matching strategy, where each WSI is divided into spatial subsets and the CAMs from subset-level predictions are regularized to match the global CAM. The final objective combines slide-level classification loss, subset classification loss, and a reconstruction regularization term between global and subset CAMs.
Strengths and weaknesses
Strengths
-
The paper addresses an important problem in computational pathology that is improving weakly supervised WSI segmentation without requiring pixel-level annotations during training.
-
The proposed Sparse-CAM and subset-matching design is intuitive and attempts to make segmentation part of the training objective rather than only a post-hoc interpretability output.
-
The experimental scope is broad, covering multiple datasets, external validation cohorts, classification metrics, segmentation metrics, and ablation studies.
Weaknesses
-
The preprocessing uses a basic tissue-mask generation strategy, but it is unclear how artifact-containing regions such as pen marks, folds, bubbles, blur, staining artifacts, or debris are handled. Since subset matching may include such regions during training, the authors are recommended to clarify any artifact filtering or QC step and provide visual results on artifact-containing WSIs from the external datasets.
-
The weakly supervised segmentation protocol needs clear explanation. The authors should explicitly state whether pixel-level annotations are used only for final evaluation or also for threshold selection, model selection, or validation.
-
Patient-level splitting should be clearly confirmed, especially for datasets with multiple slides per patient. Without patient-level separation, the reported classification and segmentation performance may be inflated. Also, Early stopping with patience 5 is reported, but the criterion is not specified; the authors should clarify whether it used only slide-level validation metrics or any segmentation/pixel-level annotation-derived metric.
-
The segmentation masks depend strongly on CAM thresholding. Figure 2 shows clear threshold sensitivity, so the authors should clarify how the threshold of 0.5 was selected and whether it was fixed before test evaluation.
-
The subset-matching assumption may introduce false-positive supervision. In positive WSIs, some subsets may contain only benign tissue, but they appear to inherit the slide-level label. The authors should explain how this issue is handled.
-
Several baselines are evaluated by thresholding attention or heatmap scores, but not all were originally designed for segmentation. The authors should clarify whether each baseline was evaluated using its strongest available localization strategy.
-
Figure 1 is very difficult to understand. The overall pipeline, Sparse-CAM module, subset-matching module, CAM generation, and loss connections are all compressed into one figure, making the method visually confusing. The authors are suggested to split it into separate panels and clearly label the main training/inference flows.
-
The positional encoding equations are standard and may be moved to the appendix unless they are modified. More importantly, the sparse-attention formulation needs clearer notation: Eq. (7) is unclear after subsampling and scatter-back indexing, Eq. (9) has ambiguous indexing and unclear per-scale/per-token weighting, Eq. (11)--(12) appear to mix sigmoid prediction with multiclass cross-entropy, and Eq. (17) has a dimensional ambiguity in the CAM computation.
Questions
-
Are train/validation/test splits performed at the patient level across all datasets?
-
Were pixel-level annotations used only for final segmentation evaluation, or also for threshold/model selection?
-
How was the CAM threshold of 0.5 selected?
-
How does subset matching avoid false-positive supervision when positive slides contain benign-only subsets?
-
Was the fully supervised comparison in Table 7 retrained under the same preprocessing, resolution, splits, and annotation setting?
-
What exactly is represented by the reported margin of error: Monte Carlo splits, bootstrap over slides/patients, or repeated model initializations?
Minor comments
-
Table 2 appears to contain a reporting error: NCPDC segmentation accuracy for WsiSSM is shown as 6.00, while Dice and IoU are very high.
-
Table 4 appears to contain a formatting error: PANDA IoU for (L_1) is reported as (49.41 ± 5318).
-
The manuscript needs proofreading for grammar, notation consistency, and figure readability.
Limitations
-
The claim of micro-tumor sensitivity is not fully supported by Dice/IoU alone. Lesion-level metrics such as small-lesion recall, FROC, or tumor-size-stratified Dice/IoU would be needed further to better support this claim.
-
The method relies on CAM thresholding, and the robustness of the final segmentation masks to threshold selection is not fully established.
-
Pixel-level segmentation evaluation appears to rely on relatively small annotated subsets for some datasets, especially the external cohorts, which may limit the strength of the segmentation claims.
-
The method relies mainly on Prov-GigaPath features, so robustness to other pathology foundation-model feature extractors is not fully established.
Paper formatting concerns
I do not observe a clear major formatting or anonymity violation.
Final justification
I thank the authors for the detailed rebuttal. The rebuttal addresses several of my major concerns, particularly regarding the evaluation protocol and weakly supervised setting. However, several of these clarifications are currently provided only in the rebuttal and should be explicitly incorporated into the manuscript.
The mathematical notation, Figure 1 presentation, table/reporting errors, and artifact robustness analysis still require revision. The segmentation baseline comparison also remains somewhat limited, as several baselines are not originally designed for segmentation.
Overall, the rebuttal improves my confidence in the technical validity of the work. I therefore update my recommendation to borderline accept, while noting that the final manuscript should clearly include the protocol clarifications and corrections discussed in the rebuttal.
We thank the reviewer for the careful assessment and for recognizing the importance of annotation-free WSI segmentation. We address the questions and limitations first, followed by the remaining presentation and reproducibility concerns.
Responses to Questions
Q1: Are train/validation/test splits performed at the patient level across all datasets?
A1: Yes. Training, validation, and test partitions are constructed at the patient level for every dataset. All WSIs from the same patient are assigned to only one partition, including datasets containing multiple lymph-node or primary-tumor slides per patient. We will state this explicitly and report the numbers of patients and WSIs in each partition.
Q2: Were pixel-level annotations used only for final segmentation evaluation, or also for threshold/model selection?
A2: Pixel-level annotations are used only for final segmentation evaluation on held-out test WSIs. They are not used for training, validation, threshold selection, subset construction, hyperparameter tuning, or model selection. Early stopping with patience 5 monitors only the slide-level validation accuracy; no Dice, IoU, pixel-level loss, or annotation-derived quantity enters model selection. This separation preserves the weakly supervised setting.
Q3: How was the CAM threshold of 0.5 selected?
A3: CAM scores are min-max normalized to [0,1], and 0.5 was fixed as the common midpoint threshold before test evaluation. It is applied unchanged to WsiSSM and every baseline, dataset, split, and test slide. Figure 2 is a sensitivity analysis showing performance across alternative thresholds; it was not used to choose a test-optimal or method-specific threshold. We will clarify this distinction and add the full threshold-performance curves.
Q4: How does subset matching avoid false-positive supervision when positive slides contain benign-only subsets?
A4: The slide label is not independently assigned to each subset. Let A(k) denote the CAM of subset Sk. The four subset CAMs are first restored to the original coordinates,
As=MΠ(A(1),…,A(K)), and only the reassembled slide-level CAM is pooled:
Ys=σ(GAP(As)),L2=ℓ(Y,Ys),L3=∥A−As∥1. There is no loss ℓ(Y,Y(k)) on an individual subset. A benign-only subset can therefore retain low activation; positive evidence may be supplied by other subsets when the reassembled slide is pooled. L3 aligns the same patch under full and restricted context rather than imposing a positive pseudo-label on every region. We will revise the diagram and text to remove this possible misunderstanding.
Q5: Was the fully supervised comparison in Table 7 retrained under the same preprocessing, resolution, splits, and annotation setting?
A5: Yes. The fully supervised method in Table 7 was retrained and evaluated using the same tissue preprocessing, patch resolution of 0.5 MPP, patient-level partitions, held-out test slides, coordinate mapping, and mask metrics. The deliberate difference is supervision: the fully supervised model uses pixel masks during training, whereas WsiSSM uses only slide labels. We will state this protocol next to Table 7 and present the comparison as a reference to the weak-to-full supervision gap, not as a like-for-like training setting.
Q6: What exactly is represented by the reported margin of error: Monte Carlo splits, bootstrap over slides/patients, or repeated model initializations?
A6: It reflects variability across the 10 patient-level Monte Carlo runs, each involving a new split and complete model training; it is not a bootstrap over pixels or slides. We report the mean and the 95% confidence-interval margin of error,
MOE=t0.975,910s, where s is the standard deviation across the 10 runs. We will also report paired statistical tests on corresponding splits; the Dice and IoU improvements are significant with p<0.05.
Responses to Questions
L1: The claim of micro-tumor sensitivity is not fully supported by Dice/IoU alone. Lesion-level metrics such as small-lesion recall, FROC, or tumor-size-stratified Dice/IoU would be needed further to better support this claim.
A1: We agree that aggregate Dice/IoU alone is insufficient to substantiate sensitivity to very small lesions. We therefore performed a tumor-size-stratified analysis on WSIs containing tumors smaller than 2 mm in held-out test set of CAMELYON. WsiSSM identifies more than 98.70% of these slides as high-risk. For localization, we additionally report sensitivity and specificity of the predicted masks, which directly quantify missed tumor tissue and false-positive normal tissue. WsiSSM improves micro-tumor sensitivity by 22.79 percentage points over the strongest compared baseline while maintaining 99.75% specificity.
R3-Table1: the comparison of various methods in segmentation of Micro-tumor
L2: The method relies on CAM thresholding, and the robustness of the final segmentation masks to threshold selection is not fully established.
A1: We agree that threshold dependence should be visible rather than summarized by one operating point. The primary results remain based on the pre-specified threshold 0.5. In the revision, Figure 2 will be expanded to report Dice, IoU, sensitivity, and specificity over thresholds from 0.1 to 0.9 for WsiSSM and representative baselines. We will also report the area under the threshold-performance curve, providing a threshold-agnostic summary while preserving the fixed-threshold primary comparison.
L3: Pixel-level segmentation evaluation appears to rely on relatively small annotated subsets for some datasets, especially the external cohorts, which may limit the strength of the segmentation claims.
A1: We acknowledge that dense expert annotation is limited in some external cohorts. Such masks require several hours per WSI and were reserved for held-out evaluation. We will report the exact annotated patient/slide counts beside each result, and moderate claims for the smallest cohorts. Importantly, the conclusion does not rely on one external subset: it is supported by the larger public dataset evaluations and multiple independent external cohorts. Future work will expand prospective, multi-center pixel-level annotation.
L4: The method relies mainly on Prov-GigaPath features, so robustness to other pathology foundation-model feature extractors is not fully established.
A1: We additionally replace the frozen Prov-GigaPath patch encoder with UNI while keeping WsiSSM, patient-level splits, training settings, and evaluation unchanged (Table2). The final revision will insert the completed UNI results to verify that the joint classification-localization capability is retained with a distinct pathology foundation model.
R3-Table2: the comparison of various feature extractors. The first three metrics are the classification results, and the last three metrics are the segmentation results.
Remaining weaknesses and revisions
Artifact handling and quality control. All slides undergo pathologist-led quality review. Slides with severe blur, poor staining, folds, or scanning artifacts are excluded; color normalization reduces inter-center staining variation. The tissue mask removes background but is not claimed to detect every artifact. Mild artifacts in diagnostically acceptable slides remain part of the realistic test distribution. We will add external examples containing pen marks, folds, staining variation, and debris, and report failure cases rather than implying complete artifact immunity.
Baseline localization fairness. Each baseline uses its localization output available from its official implementation: native attention for CLAM/DSMIL/DTFD-MIL, averaged CLS attention for TransMIL, the official repeated sampling for Bayes-MIL, and aggregated node-importance scores for BioX-CPath. All maps use identical normalization, coordinate mapping, and thresholding. Methods without an extractable localization output are omitted.
Presentation and notation. Figure 1 will be separated into (a) the overall training/inference pipeline, (b) Sparse-CAM, and (c) subset matching and losses, with the training-only subset path shown by dashed arrows. Standard positional encoding will move to the appendix. We will also rewrite the scatter-back indexing and scale weights.
Corrections. The manuscript will be proofread for typos, grammar, notation, and figure readability.