- Rating
- 5
- Clarity
- 3
- Confidence
- 3
- Originality
- 4
- Quality
- 3
- Significance
- 4
Read review
Summary
This is the first study to introduce symbolic explanations into digital pathology classification based on Multiple Instance Learning (MIL). The proposed framework represents a unique and novel contribution, enabling not only improved interpretability of MIL models but also the discovery of new insights into the interactions among morphological features. This is an important study that opens new opportunities for knowledge discovery in medical image analysis.
Strengths and weaknesses
Strengths
- To the best of my knowledge, this is the first work to introduce symbolic explanations into the MIL domain. The proposed framework is highly novel, with the potential to make an impact on the field while also offering practical utility.
- The ability to provide interpretable explanations for arbitrary MIL models without requiring any complex architectural modifications is highly appreciated.
- Rather than focusing solely on improving classification performance, this work addresses the increasingly important goals of model interpretability and knowledge discovery. In particular, it represents a pioneering effort toward generating clinically meaningful hypotheses and uncovering previously unknown relationships in digital pathology.
- Although the approach depends on the quality of the semantic map, the overall framework is reasonable and well-motivated. The generation of concept-based sub-bags through semantic-map-guided sampling, followed by the computation of alignment scores, is a natural extension tailored to the MIL setting.
Weakness
-
Since TransMIL explicitly models spatial relationships among instances, I wonder whether the sub-bag construction process may affect the model's predictions and consequently influence the computed alignment scores. There are several parts of the manuscript that remain unclear.
-
I was unable to fully understand the rationale behind the following statement:
- “We argue that, for our purposes, the Harsanyi dividends of the model’s prediction are not directly comparable to the non-transformed set function λq of a query q.” I would recommend providing additional explanation or intuition to help readers understand the motivation for this design choice.
- A considerable amount of important experimental details is deferred to the appendix. Since there appears to be sufficient space available in the main paper, I would encourage the authors to include key experimental settings and implementation details in the main text to improve readability and reproducibility.
Questions
- Has TransMIL been modified in any way to make it robust to the sub-bag extraction process?
- Why are Harsanyi dividends unsuitable for the proposed framework, and why is the proposed alignment formulation preferable?
Limitations
Although I do not consider this analysis necessary for the current submission, it would be valuable future work to evaluate the robustness of the proposed framework under a substantially larger set of logical rules. This could provide further evidence of its scalability and practical applicability in more complex settings.
Paper formatting concerns
None
Final justification
My concerns have been satisfactorily addressed. After considering the responses to the other reviewers' comments as well, I have decided to maintain my current rating.
We thank the reviewer for their feedback and address each concern below.
Semantic sub-bag construction is intended to change the model input and thereby probe how its predictions respond to the presented semantic concepts. These response changes are precisely the signal summarized by the alignment scores. The relevant concern is therefore whether the observed responses are dominated by out-of-distribution effects introduced by the sub-bag construction. To assess this, we conducted an additional analysis in the model's representation space on Camelyon16.
For every sub-bag XS, we extracted the slide-level representation ∈R256 from the final hidden layer of the MIL model, and measured its mean Euclidean distance to the k=5 nearest representations of unperturbed slides. We built the baseline distribution for this distance using all the WSIs and computed the mean distance of each slide's bag embedding to its 5 nearest neighbors among the remaining slides. We then defined the central 5th--95th percentile range of this distribution as the empirical reference interval, providing an empirical baseline for assessing whether sub-bag representations remain comparable to those of unperturbed WSIs. A sub-bag representation falling within this interval has a nearest-neighbor distance comparable to that among whole slide images.
Across all evaluated sub-bags, 71.7% fall within the empirical reference interval. In Table 2, we additionally report, for each concept subset, the mean sub-bag size, the mean distance to the 5 nearest neighbors in the reference set, and the within-interval proportion of sub-bags.
Sub-bags from which the
Normalconcept is removed exhibit larger representation shifts. However, this shift does not lead to unstable prediction directions: all evaluated sub-bags withoutNormalpatches retain positive model outputs. These results indicate that some concept-removal interventions move the representation away from the region typically occupied by real slides, but the observed prediction behavior is not explained solely by this representation shift.Table 2. Overview of sub-bags and their distances to the reference set. For each semantic concept subset, mean bag size denotes the average number of patches across all corresponding sub-bags. Mean distance denotes the average Euclidean distance from each sub-bag representation to its five nearest real, unperturbed slide representations in the reference set. The final column reports the proportion of sub-bags whose distances fall within the central 5th--95th percentile range of the leave-one-out distances observed within the reference set.
Normal, Mix)Normal, Tumor)Normal)Mix, Tumor)Mix)Tumor)We took two measures to improve robustness to sub-bag perturbations: (1) we disabled positional encoding in TransMIL, so spatial relationships are not explicitly modeled (see line 536); (2) during training, we randomly sampled patches from each slide using varying bag sizes, improving robustness to changes in both bag size and composition (line 551).
In previous work [44], the authors compared, for each feature subset S, the Harsanyi dividend of the ML model's prediction with the untransformed output λq(S) of the synthetic query model. These are different types of quantities: the Harsanyi dividend isolates the interaction contribution attributable to S alone (subtracting all subset contributions), while λq(S) is the full set function value on S. A meaningful alignment test must compare like with like. Therefore, we resorted to comparing the untransformed output of the ML model directly with λq(S). We will add this clarification in the manuscript.
After adding the revisions resulting from the rebuttal discussions, if the page limitations permit, we will move some more details into the main text to help the flow of the paper.
The computational load required for computing symbolic explanations in our framework scales exponentially with the number of features. Specifically, the number of forward passes in the MIL model required to compute (f(XS))S⊆N is 2∣N∣. Therefore, although using more than 5 features is certainly feasible, the number of features used cannot be scaled arbitrarily. If the semantic mapping includes a large number of features, the computational load can be mitigated by merging features into coarse-grained feature groups (e.g., macrophages and lymphocytes could be merged into inflammatory cells). A user could then experiment with different feature groupings to analyze symbolic explanation outcomes from different perspectives. In practice, however, we anticipate that higher-order interactions between a well-curated set of a few semantic concepts (e.g., cell types of interest) can already yield important insights.
The number of potential unique queries scales double-exponentially (2(2∣N∣)). However, computing the alignment score for any query requires no additional model forward passes and includes only a correlation. In practice, the evaluated query set can easily be restricted to the user's requirements. For example, it may be sensible to exclude queries containing more than 3-4 feature atoms, as those may be hard to interpret. In this case, the number of queries to be evaluated can be reduced to 2∣N∣+7(2∣N∣)+12(3∣N∣) in our setting (Appendix A).
Such compact concept sets are likely to be sufficient for many practical medical applications, where the analysis typically focuses on a small number of biologically meaningful components. For more complex tasks, the query space can be adapted to the user’s objectives and domain expertise. Investigating how users with different backgrounds define and interpret the query space would therefore be an interesting direction for future work.
We will add a discussion of the above-mentioned aspects to the conclusion.