- Rating
- 5
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 2
Read review
Summary
This paper presents a two-stage approach for 3D human pose estimation from sparse mmWave radar point clouds. A coarse stage first produces a kinematically constrained skeleton prior, which is then refined by a Flow-Matching model initialized from a perturbed coarse pose rather than random noise. The refinement process leverages localized Doppler features and skeleton-topology-aware attention to predict residual pose corrections. Evaluations on MM-Fi, mmBody, and Reb3D demonstrate strong performance, with the method achieving the best average PA-MPJPE among the compared baselines.
Strengths and weaknesses
Strengths
S1. The paper is likely the first to apply Flow Matching to radar-based skeleton refinement. While the novelty is relatively focused, it represents a meaningful departure from prior diffusion-based approaches.
S2. Initializing the Flow-Matching process from the coarse pose prediction, rather than using the coarse pose only as a conditioning signal, is a well-motivated design choice. This component is supported by both the initialization ablation in Table 4 and the integration-step analysis in Fig. 10, making it one of the most thoroughly validated aspects of the method.
S3. The localized Doppler aggregation mechanism is a promising idea. By conditioning Doppler features on the evolving pose state, the method aims to inject motion information in a more localized and physically meaningful manner than global aggregation schemes.
Weaknesses
W1. The localized Doppler mechanism is not independently validated. Although it is presented as a key component of the method, the paper does not include an ablation comparing localized and global Doppler aggregation, nor a comparison with removing the Doppler token entirely. Sensitivity to the aggregation radius or Gaussian weighting parameter is also not examined. Consequently, it remains unclear whether the observed gains are attributable to the localized design itself.
W2. Because the Doppler component is not isolated experimentally, the evidence supporting the overall contribution remains incomplete. The benefit of using the coarse pose as the Flow-Matching source is clearly demonstrated, whereas the contribution of the Doppler mechanism remains uncertain.
W3. The comparison omits the most recent radar point-cloud methods — e.g., mmChainPose (reports on mmBody) and mmGAT, which the paper itself cites ([21]). Of course, most of the work that wasn't compared didn't publish its code, so this isn't very important.
Questions
Q1. The localized Doppler aggregation is presented as a central component of the method, yet its contribution is not isolated experimentally. Could the authors provide an ablation study comparing the proposed localized Doppler design with a global Doppler variant, and ideally a version without Doppler features?
The main factor that will influence my final assessment is whether the contribution of the localized Doppler mechanism can be demonstrated more convincingly.
Q2. Please report variance for the main results in Tables 1–3. Several improvements over mmDiff are relatively modest (for example, on Reb3D), making it difficult to assess their statistical significance. Reporting mean ± std would help establish the robustness of the reported gains.
Q3. The benefits of the flow-refinement stage are not entirely clear from the current results. In several settings, the full model improves PA-MPJPE while providing limited gains, or even showing slight degradation, in MPJPE and bone-length error relative to the coarse-only variant (SRL+LTA+KPC). Could the authors discuss the conditions under which flow refinement is most beneficial and whether the additional inference cost is justified in practice?
Limitations
-
Scope of the empirical support. The benefit of the most novel component, the localized Doppler mechanism, is not isolated through any ablation study, and the main comparisons (Tables 1–3) are based on single runs. The authors could acknowledge that the contribution of the Doppler mechanism and the statistical significance of the headline improvements remain to be established.
-
Metric-dependent benefit. The flow-refinement stage improves PA-MPJPE and joint velocity but is neutral or negative with respect to MPJPE and mean bone-length error in several settings. It would be more accurate to state explicitly, as a limitation, that the refinement primarily improves articulated structure and motion consistency rather than absolute joint-position accuracy.
Paper formatting concerns
not specifically
Final justification
The rebuttal resolves my main concerns:
The localized Doppler mechanism is now directly validated against both No-Doppler and Global-Doppler variants across all three datasets, together with a neighborhood-radius sensitivity analysis.
Multiple-run results with small standard deviations support the stability of the reported improvements.
The authors also clarified that the refinement mainly improves articulated structure and motion consistency, while gains in absolute MPJPE are more limited.
The novelty remains focused on the integration of existing components, but the new evidence sufficiently supports the main technical contribution. I therefore raise my rating to 5 (Accept).
We sincerely thank the reviewer for the thoughtful and constructive comments. The questions have helped us present the motivation and contributions of our work more clearly, strengthen several technical explanations, and improve the overall quality of the manuscript.
W1 Response:
Thank you for this suggestion. We conducted a controlled ablation with three variants: No Doppler, Global Doppler, and the proposed Localized Doppler. All experimental settings were kept identical, with the Doppler representation being the only changed component.
In the No Doppler variant, the Doppler token is removed. In the Global Doppler variant, Doppler features are aggregated over the entire radar frame and shared across all joints. In the proposed Localized Doppler variant, Doppler features are aggregated separately around each joint to provide joint-specific motion cues. The comparison was conducted on all three datasets, as reported in the following table.
The results consistently support the proposed localized Doppler design. Localized Doppler achieves the best MPJPE and PA-MPJPE on all three datasets. Notably, global aggregation does not consistently improve upon removing the Doppler token, suggesting that indiscriminate frame-level Doppler aggregation may introduce motion cues unrelated to individual joints. In contrast, the proposed localized aggregation associates Doppler evidence with the evolving joint locations and provides more relevant joint-specific motion information.
To examine the sensitivity of localized Doppler aggregation, we varied the neighbourhood radius r on mmBody while keeping all other settings unchanged. For each joint, Doppler features were aggregated only from radar points within radius r. The Gaussian width was coupled to the radius as σ=r/2, so this experiment also evaluates the effect of the weighting scale.
The radius has a clear influence on the final performance, as it determines the spatial range from which joint-specific Doppler evidence is collected. We selected r=0.10 m based on the typical local scale of the human skeleton, so that the neighbourhood is sufficiently large to include useful radar returns without extending excessively into adjacent body regions. The results support this empirical choice, with r=0.10 m achieving the best MPJPE and PA-MPJPE among the tested settings. The corresponding Gaussian width is σ=0.05 m.
W2 Response:
This point has also been addressed in our response to W1. Please refer to the Doppler-mode and neighbourhood-radius ablations and the accompanying analysis above.
W3 Response:
Thank you for pointing this out. mmChainPose reports an MPJPE of 65.8 mm and an OKS of 0.6320 on mmBody. However, neither mmChainPose nor mmGAT provides an official public implementation. We therefore did not include them in the baseline table, as an independent reimplementation could introduce avoidable implementation bias. Our comparisons are limited to radar point-cloud methods that can be fully reproduced and retrained under the same protocol.
Q1 Response:
This point has been addressed in detail in our response to W1. The added ablations consistently show that Localized Doppler outperforms both Global Doppler and No Doppler across all three datasets, directly supporting the contribution highlighted in this question. Please refer to W1 for the full results and accompanying analysis.
Q2 Response:
Thank you for this suggestion. We repeated RadarFlowPose with multiple independent training seeds and now report the mean ± standard deviation on all three datasets. The results are 74.37 ± 0.33 / 55.71 ± 0.21 mm on mmBody, 66.09 ± 0.36 / 50.47 ± 0.17 mm on MM-Fi, and 64.29 ± 0.23 / 53.97 ± 0.35 mm on ReB3D for MPJPE/PA-MPJPE, respectively. The small standard deviations indicate that RadarFlowPose is stable across independent runs.
We are also updating Tables 1–3 to report the mean ± standard deviation wherever repeated runs are available. For mmDiff, we attempted to reproduce the reported results using the released code, but the reproduced performance differed substantially from that obtained using the released pretrained weights. We therefore used the pretrained model for evaluation, which does not allow training variance to be estimated.
In addition, the pretrained model is fixed to a 17-joint skeleton. ReB3D therefore had to be reduced from 27 to 17 joints for mmDiff, whereas RadarFlowPose was evaluated on all 27 joints. We will state this clearly below the table, and the relatively close ReB3D results should therefore be interpreted with caution.
Q3 Response:
Thank you for this comment. To clarify where the refinement stage is most useful, we report the joint-wise errors of the coarse-only model and RadarFlowPose on ReB3D. RadarFlowPose reduces MPJPE for 18 of the 27 joints and PA-MPJPE for 21 of the 27 joints, with 14 joints improved under both metrics.
The gains are not uniformly distributed across the skeleton but are concentrated in the most challenging articulated regions. RadarFlowPose reduces MPJPE for all eight lower-limb joints and consistently improves the distal hand joints under both MPJPE and PA-MPJPE. This distribution is consistent with the intended role of Flow Matching: preserving the already plausible global skeleton while refining residual errors in peripheral joints that are difficult to recover from sparse radar observations.
The absolute per-joint gains are modest, but their distribution is consistent with the intended role of the refinement stage. The coarse model already estimates the global body position and many torso joints reasonably well, leaving less room for improvement in these regions. Flow refinement is therefore most useful when the remaining errors arise from local limb articulation and relative joint configuration. This also helps explain why the improvement is more consistently reflected in PA-MPJPE than in overall MPJPE.
Bone-length error is not explicitly included in the Flow-Matching objective and therefore does not improve in every setting. However, the refinement improves bone-length consistency on MM-Fi and ReB3D, as shown in Figs. 6 and 7.
The refinement stage is most beneficial when the coarse estimator has already recovered a plausible global skeleton but still exhibits residual errors at challenging peripheral joints, such as the hands, feet, and head. Its role is therefore to preserve the coarse skeletal structure while making targeted local corrections, so the improvements are naturally concentrated on difficult joints rather than the entire skeleton. The coarse estimator itself is lightweight (3.07M parameters), while the complete system still processes a 297-frame sequence in 79.77 ms (0.2686 ms/frame, 3723.16 FPS) and remains substantially faster than mmDiff. We therefore believe that the modest computational overhead is well justified by the improved pose refinement.
We will add the joint-wise results and qualitative examples and clarify that Flow refinement mainly improves local articulation and relative skeletal structure.
L1 Response:
These concerns have been addressed in our responses to W1 and Q2. We added controlled ablations comparing No Doppler, Global Doppler, and the proposed Localized Doppler on all three datasets. The results consistently support the contribution of the localized Doppler mechanism. We also repeated RadarFlowPose with multiple independent training seeds and now report the mean ± standard deviation on all three datasets. The small standard deviations indicate stable performance across independent runs.
L2 Response:
As discussed in Q3, Flow refinement provides more consistent improvements in articulated structure and motion consistency than in absolute MPJPE or bone-length error. We have clarified this performance profile in the revised manuscript.