acceptodds
Published as a conference paper at NeurIPS 2026

H-Flow: Self-supervised Human Scene Flow via Physics-inspired Joint Multi-modal Learning

Zhanbo Huang, Xiaoming Liu, Yu Kong

Abstract

Parametric human models capture global pose but overlook fine-grained surface dynamics. Generic scene flow estimates dense motion but struggles with articulated humans and lacks 4D ground truth. To bridge this gap, we introduce H-Flow, a dense 4D motion representation that captures non-rigid deformations beyond skeletal kinematics. We estimate H-Flow from monocular video via a unified multi-head architecture that jointly perceives pose, depth, and flow. To overcome the scarcity of dense motion annotations, we propose a self-supervised learning paradigm that embeds geometric, structural, and biomechanical priors into optimization. These cross-modal constraints tightly couple pose, depth, and flow, so that improving any one modality simultaneously drives the others toward consistency. For evaluation, we present DynAct-4D, a high-fidelity synthetic benchmark providing dense 4D ground truth for complex human movements. Extensive experiments show that our method outperforms state-of-the-art scene flow baselines. Furthermore, H-Flow serves as an effective motion primitive, bringing substantial improvements to downstream tasks including action recognition and video generation. Models, code, and resources will be released upon publication.

Keywords:
Atlanta, Main Track

Reviews

Among:
Shape:
123456this paper, Top 24%
Figure 1. Mean review rating of the reviewed papers at NeurIPS 2026. This paper averages 4.67 over 3 reviews, above 76% of the others.
Reviewer_nPp7OpenReview ↗
Rating
5
Clarity
4
Confidence
3
Originality
3
Quality
3
Significance
3
Read review
Summary

This paper addresses scene flow estimation of human bodies from video sequences. The authors propose a self-supervised framework based on a transformer architecture that jointly predicts depth, optical flow, human pose, and camera parameters. A key contribution is the introduction of four physics-inspired regularization terms—geometry, structure, biomechanics, and consistency—which are intuitive and well motivated. A second contribution is the DynAct4D benchmark, a synthetic dataset designed for this task. Experiments on both in-domain and out-of-domain settings demonstrate state-of-the-art performance.

Strengths and weaknesses

Strengths

  • The paper is generally well written and easy to follow.
  • It tackles a challenging problem: free-form scene flow estimation of human bodies, where rigid-motion assumptions do not hold and large-scale annotated data is difficult to obtain.
  • The overall model design is reasonable and clearly explained.
  • The four regularization terms are intuitive and appear thoughtfully designed.
  • Experimental results are comprehensive and show strong performance compared to prior methods.
  • Sufficient implementation and training details are provided in the appendix, supporting reproducibility.

Weaknesses

  • The Fit3D benchmark is used in the evaluation, but there is little to no description of it in either the main paper or Table 1. Additional background and dataset details would be helpful.
  • The evaluation primarily reports overall EPE averaged across the human body. A more detailed analysis would strengthen the paper. For example, how does performance vary across different body parts, motion types, or clothing/garment conditions? Does the proposed method consistently outperform baselines across all scenarios, or are the gains concentrated in specific cases?
  • The reported errors are relatively small (~20 mm). It would be valuable to include zoomed-in visualizations or analyses that better illustrate the spatial distribution of errors and highlight remaining failure cases.
  • Since DynAct4D is a synthetic dataset with available ground truth, it is somewhat surprising that the paper does not explore pretraining on DynAct4D followed by testing or fine-tuning on real-world datasets. Such a setup is common and seems like a natural use case for the proposed benchmark. The authors should discuss why this strategy was not considered.
  • More broadly, given that obtaining dense scene-flow ground truth from cameras is difficult, have the authors considered generating synthetic LiDAR data alongside DynAct4D? This could potentially simplify scene-flow annotation and create additional research opportunities.
  • Initially, I was surprised that the model converges to meaningful solutions given the complexity of the self-supervised objectives and regularization terms. Later, I realized that the framework includes a distillation (anchoring) mechanism. It would be helpful for the authors to more clearly explain the role of this component. Specifically, what information does the distillation process provide, and why does it prevent collapse? Are there qualitative results or visualizations showing the behavior of the model when trained without anchoring?
Questions

please refer to weakness

Limitations

I do not see discussions on limitations of the work; Broader impacts are not included in the paper either.

Paper formatting concerns

No

Final justification

My concerns regarding the fine-grained EPE analysis and the "anchoring" issue have been largely addressed, and my overall assessment remains positive toward acceptance. That said, my experience with scene flow primarily comes from application domains other than human body motion, so please weigh my comments accordingly.

Reviewer_vVSEOpenReview ↗
Rating
5
Clarity
3
Confidence
4
Originality
3
Quality
3
Significance
4
Read review
Summary

In this paper, the authors have introduced H-Flow, which is a dense human scene flow method capturing both skeletal kinematics and surface deformation. They contributed a unified framework which can not only estimate the flow from monocular video, but also estimate the pose and depth as auxiliary outputs. To facilitate the comparison with other existing approaches, the authors also established DynAct4D benchmark, where the proposed H-Flow delivers the best performances.

Strengths and weaknesses

Strengths:

  1. The authors have contributed an important approach to the community which can achieve high fidelity dense flow estimation under in-the-wild setting. The physics inspired cross-modal coupling has a good motivation.

  2. The paper is generally well-written and the authors have provided comprehensive experiments and very nice visualizations to demonstrate the performance of the model and their idea. The method is clearly described.

  3. The proposed approach delivers promising results compared with existing approaches selected as baselines on this new benchmark with very good zero shot generalization performances.

Weaknesses:

  1. In Table 2, it would be good to report some computational overhead, e.g., inference speed, trainable parameter number and GFLOPs to have a better comparison regarding the efficiency of different approaches.

  2. As the dataset may contain different action types with different density. The authors are encouraged to group them according to the action density (e.g., the motion speed and complexity), and then report the performance per group and make comparison with baselines for these fine-grained results. That can sharpen the analysis section.

  3. I am wondering how helpful this scene flow estimated by H-Flow helps for the downstream tasks, e.g., action recognition, when we compare the results of H-Flow with the other coarsely estimated flow. The authors should somehow illustrate its potential usage in motion understanding related subfields.

Questions

My questions are fully based on the weaknesses I mentioned above.

1.Could the authors report the computational cost of H-Flow, including inference speed, the number of trainable parameters, and GFLOPs, to provide a more complete efficiency comparison with the baselines?

2.How does H-Flow perform on actions with different motion speeds, densities, and levels of complexity? A grouped evaluation by action density would provide a more fine-grained understanding of the method’s strengths and limitations.

3.Can the authors demonstrate whether the high-fidelity scene flow estimated by H-Flow benefits downstream tasks such as action recognition or motion understanding, especially compared with more coarsely estimated flow?

Limitations

The limitations are described in the conclusion section.

Paper formatting concerns

N/A

Final justification

The authors have addressed all my concerns and thereby I would like to raise my score to 5. I believe this contribution can be benefitial to the community.

Reviewer_3eGHOpenReview ↗
Rating
4
Clarity
3
Confidence
4
Originality
3
Quality
2
Significance
2
Read review
Summary

H-Flow is a trained model that takes a video of a person as input, and outputs a multimodal representation that includes pose information (through sparse joint keypoints) but also dense surface deformation (via scene flow and depth). It also includes a self-supervised learning objective: output modalities are mostly supervised via cross-modal physical priors (and some weak expert pseudo-labeling). Finally, the authors include a synthetic dataset as a new benchmark.

Strengths and weaknesses

Strength

  • The approach is well-motivated, the method is quite clearly explained.
  • The self-supervised constraints are sensible, and the fact that H-Flow outperforms the anchoring expert on MPJPE is a strong proof of their effectiveness.
  • The authors showcase strong results on several downstream tasks (3D flow, pose and depth estimation)

Weaknesses

  • The results reported for other methods seem completely off. For Camera-HMR on 3DPW for example, they report 56.0 and 35.1 for MPJPE and PA-MPJPE. The same could be said for Prompt-HMR, and more importantly, Sam 3D Body. This brings doubt on the main strength above.
  • For the 3D flow modality, as far as I can tell, the authors do not cite, comment or compare to any recent paper following the major shift initiated by Dust3r derivatives, such as Align3R or "shape of motion" (not accounting for D4RT as it is too recent). This weakens the paper significantly
  • It is unclear how much dynamics are modeled in the DynAct4D dataset (see questions below).
  • The central focus of the paper, reconstructing the dynamics of the deformable surface (soft tissue, clothing) is really weakly evaluated: either on SMPL-X annotations, or on the new DynAct4D dataset (see previous point).
Questions
  • How do you obtain numerical results for your baselines? How do you explain the huge gap between their original reported results and yours? This is my main concern as the significance of the paper rests on this.
  • In your ablation studies, you show results "w/o distillation anchor". Intuitively, I would expect the training to quickly collapse to a constant solution without them (zero mask, no flow, constant pose...). There is no training objective left that depends on the input as far as I can tell. Can you comment on that? Is there an extra supervision on the mask?
  • Could you provide some details on how clothing/hair is animated in DynAct4D? For example, you list BEDLAM as 'simulated' as well, but as far as I know, they only model clothing dynamics, not hair dynamics.

Minor questions and remarks:

  • The statement "Estimating dense human scene flow without ground truth is a highly ill-posed problem" appears to conflate two distinct issues. The estimation problem is inherently ill-posed due to ambiguities, whereas the absence of ground-truth annotations is a challenge for supervised training rather than a source of ill-posedness
  • From what I understand, H-Flow is trained solely from the anchors' predicted labels, without matching soft outputs, or intermediate representations. As such the method appears closer to pseudo-labeling than distillation. Can you comment on that?
  • The sentence "The four constraints above do not exhaust the full optimization" (l.210) is somewhat difficult to parse. I would suggest rephrasing.
  • You write (l.275) that you evaluate pose estimation "to verify that joint estimation does not compromise companion modality quality". Should this not be the other way around?
  • You write (l.279): "Joint estimation provides H-Flow’s pose head with the metric depth required for absolute world-space localization, a signal that dedicated pose estimators must infer indirectly from monocular cues". Could you please elaborate on that?
Limitations

Limitations could be discussed further, in particular regarding the chosen priors. For example, the center of mass prior does not always hold for dynamic motion. Or the fact that "every surface point sits within a few centimeters of an underlying bone" is not exactly true for loose clothing.

Paper formatting concerns

No concern

Final justification

The authors have addressed my main concerns somewhat, but I remain not fully convinced by the overall quality of the paper at this stage. Given the rating of the other two reviewers, I will concede to their points and raise my rating to borderline accept.

Comments on the paper

1 comment
Meta-review

This paper received one accept, one borderline accept, and one reject, making it a borderline case. For the major weakness, the reject reviewer mentioned that the reported metrics for baseline methods including Camera-HMR, Prompt-HMR and Sam 3D Body appear inaccurate, casting uncertainty over the paper’s core advantages, and the work fails to compare its 3D flow module against recent Dust3r-inspired approaches like Align3R and Shape of Motion, substantially undermining its contribution. Also the evaluation of the paper’s main goal, recovering deformable surface dynamics such as soft tissue and clothing, is inadequate, relying only on SMPL-X labels and the poorly characterized DynAct4D dataset with unclear dynamic modeling scope. However, the other two reviewers remain overall positive as the paper is well presented with solid experiments. After reading the paper and reviews, AC feels it is possible for authors to address these concerns in the revision. AC thus gives initial positive review.