- Rating
- 5
- Clarity
- 2
- Confidence
- 4
- Originality
- 2
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper proposes FactorizedHMR, a two-stage video HMR system motivated by the observation that reconstruction uncertainty is non-uniform across the body. Typically, the torso/root is well-visible and therefore well-constrained while other parts of the body are more ambiguous. Stage 1 is a transformer that deterministically regresses a "structural anchor" which consists of the torso's body posture, shape and the root trajectory in camera frame. Stage 2 is a masked conditional flow-matching module that completes the remaining 13 non-torso joint rotations, the joint locations themselves and the root trajectory in world frame. It is trained with joint-bone consistency loss, a 2D projection loss, and a classifier-free guidance variant. Training uses AMASS / BEDLAM / H36M / 3DPW plus newly synthesised videos. The results beat baseline methods on all datasets while being less runtime and memory efficient than related methods.
Strengths and weaknesses
Paper Strengths The factorisation of HMR uncertainty, torse & camera frame vs non-torso and world frame, is a useful framing and is empirically motivated by the appendix per-joint analysis. The 3DPW-XOCC results especially in Tab. 4 are strong, demonstrating that the method can indeed substantially improve recovery in case of heavy occlusions / degradations. The torso-region panel of Tab. 2 is convincing, as it consistently outperforms GVHMR across all datasets. The progressive ablation in Tab. 5 is mostly structurally clear and the the synthetic-data pipeline for data generation, while building upon pre-existing models, is a good contribution to the field.
Major Weaknesses
-
Tab. 5 ablation is misleading. Row 1 ("Stage 1 Model") is degenerate, as the stage 1 model alone predicts only the torso anchor, so that the stage 2 model would be required to recover a complete body pose. Thus, the large gain of 25.1 PA-MPJPE from row 1 to row 2 is just coming from the fact that the stage 1 model is not capable of predicting the entire body. No row in the table compares masked CFM Stage 2 to a regression-based or diffusion-based Stage 2 with the same composite latent, mask, and conditioning.
-
Two novelty claims overstate what the paper contributes against prior work. The masked path (Eq. 6), inference-time z_K re-imposition, and partial CFG together reduce to a masked diffusion recipe already used by, e.g., RoHM. Similarly, what Sec. 3.3 calls "feature-aware CFG" is a partial-condition CFG variant that drops observation-heavy conditions while keeping anchor ones is a well-known technique. Both claims should be softened or removed.
-
Unflagged regressions. First, the paper attributes the worse PA-MPJPE in EMDB to a SMPL-vs-SMPL-X protocol mismatch. However, the same issue applies on RICH and 3DPW where Ours wins, so the explanation does not transfer cleanly and the regression is left effectively unaddressed. Second, several temporal-smoothness numbers in Tab. 3 are much worse than the baselines. These directly contradict the introduction's "temporally consistent video HMR" framing and weaken the paper's statement that world-space results as "broadly competitive".
-
No generative-HMR baselines. ScoreHMR, GenHMR, RoHM, and others, are all cited in Sec. 2 but none appear in the experiments. RoHM in particular is the most direct masked-diffusion HMR baseline, it factorises trajectory vs local pose and refines them in stages, and the paper inherits its joint-position representation directly. Given that Contribution 2 is explicitly about probabilistic HMR via flow matching, the works lack any head-to-head comparison against this class of methods.
-
Efficiency framing. Sec. 4.2 reports 3.92 s for a 1193-frame clip vs GVHMR 0.41s at 50 ODE steps, with 1057.0 MB peak GPU memory vs 303.6 MB, which is close to a 9.5x slowdown and a 3.5x memory increase. The paper presents this as 304.45 amortised fps, which might be technically correct but misleading about per-sequence latency for a video method. Fig. 7 also show Stage 2 quality saturates by roughly 20 ODE steps, with 20 actually best on PA-MPJPE. However, the main paper's numbers in Tabs. 1, 3, and 4 are reported at 50 steps. A 20-step variant would improve PA-MPJPE and improve efficiency, so it's not clear why it hasn't been used across experiments.
Minor Weaknesses
-
Reproducibility gaps in the specifics. Rotation parameterisation (axis-angle vs 6D vs quaternion), learning rate, batch size, total iterations, CFG dropout rate during training, the projection-loss ramp schedule, individual loss weights across the multi-term geometry losses, training-mixture sampling weights, total parameter count, and the sliding-window / clip-length protocol are all not given. Thus, the method cannot be re-implemented from the paper alone.
-
Limitations. The limitations paragraph is short and no failure cases are shown.
-
Notation overloads. rho is reused for both the 3D robust penalty in Eq. 8 and the 2D pixel-space penalty in Eq. 9; K is reused for the "known" partition subscript in z_K and the camera intrinsics matrix in Pi_K (Eq. 9); t collides as frame-time index in Eq. 1 and as flow-matching time in Eqs. 6-7.
-
Tab. 6 hip duplication. Left hip and right hip values are identical across all three datasets and the mean, while this is not the case for every other paired joint. Might be a copy paste error.
Overall The paper introduces an interesting framing, separating well-constrained torso from often ambiguous non-torso and world motion, and improves accuracy on the occlusion-heavy 3DPW-XOCC benchmark (Tab. 4) and on world-space MPJPE for EMDB and RICH (Tab. 3). However, the ablation does not isolate the central masked-CFM or feature-aware-CFG claims, the novelty framings are partially overstated, several regressions on EMDB PA-MPJPE and on temporal-smoothness metrics are left unaddressed, and the closest generative-HMR baselines are missing from the experiments.
Questions
What would most strengthen the paper: (a) a flow-matching vs regression vs diffusion Stage 2 comparison with identical input-output structure to clarify the Tab. 5 Row 1 ablation; (b) a numerical comparison to at least one direct generative-HMR baseline (RoHM in particular) on Tab. 3 or Tab. 4; (c) a 20-step ODE variant of the headline tables with reported runtime; and (d) somewhat weakening the novelty statements.
Limitations
The limitations paragraph is short and does not show any qualitative nor quantitative results, such as failure cases, per-joint error analysis, the results' variances, etc.
Paper formatting concerns
none
Final justification
I thank the authors for a thorough rebuttal that answers most of my concerns, such as the novelty claims, regressions, and the runtime cost related concerns. My one remaining doubt is the ablation (Tab. 5 Ablation), where their new comparison puts a plain deterministic single-stage baseline within only 0.9 PA-MPJPE of the full much more complicated system. However, as most concerns have been addressed, I'll raise my score to accept.
We thank the reviewer for the detailed technical comments. We are encouraged that the review recognizes the useful framing, the empirical support from the per-joint analysis, the torso-region evidence in Table~2, and the relevance of occlusion-heavy robustness evaluation. Reviewer ov1a and Reviewer U2DP also recognized the core deterministic--probabilistic motivation, so we think the main contribution should remain this factorization, not the standalone novelty of every individual component. We agree that several claims should be softened, especially around masked path, feature-aware CFG, and broad metric claims.
Tab 5. Ablation
We agree with the reviewer that the wording around Table 5 was confusing. The Stage 1-only row should not be read as a full HMR competitor; it was meant as an anchor-only diagnostic showing what is recovered by the torso/root estimate alone. We will fix the caption and text so this row is not over-interpreted.
We also add the new Table 1 diagnostic below, which directly looks at the estimation paradigm. The important pattern is simple: det+det and prob+prob are both worse than our det+prob design, and the part-aware single-stage variants also do not reach ours.
This supports the same interpretation as Table 2, but in a more direct way. Making every variable deterministic loses the benefit of probabilistic generation for ambiguous non-torso parts; making every variable probabilistic also hurts because stable torso/root variables should act as an anchor. So we will keep the claim simple: Table 5 wording will be fixed, and Figure 1 shows that the mixed deterministic torso + probabilistic non-torso design is stronger than using one paradigm everywhere.
Novelty claims around masked path and feature-aware CFG
We agree with the reviewer that masked generation paths, re-imposing known coordinates during sampling, and partial-condition CFG should not be presented as isolated inventions. We do not claim that these are individually new contributions, and will soften the wording & cite related masked/guided generative reconstruction methods such as RoHM more explicitly.
Our key difference from RoHM is mainly the objective and the semantics of the mask. RoHM uses diffusion for robust motion reconstruction by denoising/infilling noisy or occluded motion estimates, with a global-trajectory/local-motion decomposition. In contrast, FactorizedHMR uses the mask to implement a deterministic--probabilistic division of labor inside video HMR: Stage 1 deterministically estimates the torso/root and camera-space structural anchor, while Stage 2 probabilistically completes only the ambiguity-prone non-torso articulation and world-motion variables. So the known subset in our masked path is not only a visible/noisy observation to preserve; it is a learned structural anchor that is deliberately excluded from generation.
We will revise the claim to a narrower statement: FactorizedHMR adapts masked conditional flow matching and partial CFG as implementation tools for a reliability-aware HMR factorization.
Regressions in PA-MPJPE and temporal smoothness
Our claim is not that FactorizedHMR dominates every metric: PA-MPJPE/PVE and contact-related metrics are mixed, while the clearer gains are in the region-wise torso/non-torso analysis and drift-sensitive W-MPJPE. We will revise broad statements such as “consistently outperforms prior methods” to “competitive on standard benchmarks with targeted gains,” and explicitly mention jitter/foot-sliding as remaining limitations. We will also avoid over-explaining this only by SMPL-vs-SMPL-X mismatch, and just describe the observed metric pattern directly.
Direct generative-HMR baseline comparison
GENMO is already included as a recent generative/probabilistic-style baseline, but we agree that the paper should mention other generative HMR methods more explicitly. We therefore add the following comparison on 3DPW, while being careful about protocol differences:
For RoHM, the authors provide model weights, but not a straightforward evaluation path for video-level camera-coordinate metrics in the same setting we use, and RoHM also did not originally report 3DPW/EMDB/RICH comparisons. So we attempted our own reproduction with the released weights and our evaluation path. We will clearly mark this as our best-effort reproduction, since preprocessing and evaluation details may differ from what RoHM originally intended. For ProHMR, the PA-MPJPE number is the official score reported in its paper, not our reproduction. This comparison is not meant to claim a fully matched protocol for every generative HMR method, but to answer the reviewer that we did check available generative/probabilistic baselines and will state the compatibility limits rather than hiding them.
Efficiency framing and 20-step ODE variant
This is a fair point, and is partly already answered by the ODE-step sweep noted by the reviewer. In the main paper we merely used the 50-step CFG setting because it was the conservative setting for reporting, not because we believe it is the only practical one. Since Stage 2 is probabilistic, it does add runtime and memory compared to GVHMR, and we should state this more plainly.
Table 3: Runtime / Memory Analysis
We will re-check the results and move the practical lower-step setting discussion from Figure 7 into the main text. If the 20-step/no-CFG setting preserves the accuracy trend, we will report it as the faster operating point and keep the 50-step setting only as the conservative/default one. The revision will avoid making the runtime look better than it is, but also avoid making the 50-step number look like the required inference cost.
Reproducibility details
We will add the rotation parameterization, learning rate, batch size, number of iterations, and other relevant variables to training and inference to the appendix. We will also separate details needed to reproduce training from details needed only for evaluation. Baseline repository snapshots/checkpoints and preprocessing protocols will be documented with the evaluation details, while loss weights and optimization schedules will be documented with training. We will also fix the notation/minor errors pointed out by the reviewer, including robust penalty notation, camera/known-partition symbols, and frame-time vs flow-time notation.