- Rating
- 4
- Clarity
- 3
- Confidence
- 5
- Originality
- 3
- Quality
- 3
- Significance
- 2
Read review
Summary
This paper proposes a framework called PhyMo for learning the geometry, appearance, and continuous motion states of dynamic 3D scenes from multi-view dynamic videos. The primary motivation lies in the fact that robust rendering quality in dynamic NeRF/3DGS methods does not necessarily translate into accurate 3D motion reconstruction. Existing methods may exploit appearance changes (e.g., color or opacity adjustments) to fit observations instead of learning reliable deformation and motion trajectories. The authors refer to this problem as "appearance shortcuts."
To address this issue, this paper introduces two main components. First, Motion-Aware Trajectory Representation uses a Gaussian motion confidence-based gating to regulate the release of typical appearance residuals, thus prompting the model to explain dynamic changes through deformation rather than appearance compensation. Second, the Continuous Motion Evolution module predicts displacement, velocity, and acceleration and enforces bidirectional kinematic consistency to improve temporal continuity and future motion extrapolation capabilities. Experiments on multiple dynamic scene datasets demonstrate improvements in rendering metrics and dynamic geometry chamfer distance.
Strengths and weaknesses
main Strengths
1.This paper explores an important and well-motivated problem. Distinguishing between visually plausible rendering and physically or geometrically correct motion is crucial for dynamic scene reconstruction, robotics, embodied AI, and world modeling. This paper correctly points out that RGB-level quality alone is insufficient when downstream applications require reliable motion and geometric information.
2.The proposed modules are largely aligned with this motivation. The motion confidence gate directly addresses the appearance shortcut problem by limiting the opacity and SH residual flexibility when learned deformations are unreliable. The continuous motion evolution module further enhances the temporal consistency between displacement, velocity, and acceleration. These designs collectively form a coherent framework for improving geometry-aware interpolation and motion extrapolation.
3.The evaluation methods are also relatively appropriate. In addition to standard metrics such as PSNR, SSIM, and LPIPS, this paper reports dynamic geometry chamfer distance, which is more directly related to whether the moving geometry is reconstructed in the correct 3D position. Ablation experiments further demonstrate that motion guidance, continuity loss, and the motion network all contribute to the final performance.
main Limitations
1.The practical generalization boundary of this method is still unclear. PhyMo relies on multi-view video, known camera poses, and a relatively standard 3DGS optimization pipeline. Although experiments covered four datasets, the number of truly complex real-world cases remains limited. Whether motion confidence gating and continuity constraints remain stable under sparse viewpoints, monocular normal video, noisy camera poses, severe occlusion, crowded dynamic objects, or object disappearance and reappearance is currently unclear. Further visualization of difficult and failed cases will help strengthen the persuasiveness of this paper.
2.The term "physical dynamics" seems to be stronger than what the method actually models. The current formulas primarily enforce kinematic consistency between displacement, velocity, and acceleration without explicitly modeling forces, mass, contact, collision, friction, material properties, or other physical factors. Therefore, more accurately, the method is a kinematically aware dynamic 3D geometry framework rather than a complete physical dynamics model. Its applicability to complex contact, strong non-rigid deformation, fluid motion, object breakage, or topological changes remains uncertain.
3.Motion confidence gating also introduces guided sampling risk. The confidence score is calculated from the local variations of the learned deformation field, but the deformation field itself is learned during the optimization process. If the deformation is not accurate enough in the early training phase, gating may incorrectly suppress appearance residuals or prematurely allow appearance shortcuts. Hyperparameters such as threshold, temperature, minimum confidence, and gradual time scale may also affect performance, but their robustness across different datasets and motion types has not been fully analyzed.
Questions
1.How does this method perform with sparse multi-view input, monocular standard video, or noisy camera poses? Does the motion confidence gate become unstable when deformation estimation is inaccurate?
2.Could the authors provide more qualitative results for complex scenarios such as severe occlusion, object disappearance and reappearance, crowded multi-object interactions, rapid non-rigid motion, or complex contact?
3.Since the current method primarily enforces kinematic continuity, could the authors clarify whether they plan to extend it to modeling explicit physical properties, such as mass, force, friction, collision, or material parameters? If not, the paper should more clearly distinguish between kinematic consistency and physical dynamics.
4.How sensitive is the gating mechanism to deformation mass and its hyperparameters? Further analysis on different datasets and motion patterns would be helpful.
Limitations
The main limitations of this method lie in its input requirements, the limited depth of physical modeling, and the robustness of the gating mechanism. The method relies on multi-view video and known camera poses, which limits its applicability in more open, sparse, or noisy acquisition environments. Furthermore, the physical model to be protected is primarily a kinematic model rather than an explicit model. Finally, since confidence gating originates from learned deformations, there may be optimization instability or early decision errors. These limitations require a clearer discussion and, ideally, can be addressed through additional failure cases and parameter sensitivity analyses.
Paper formatting concerns
No major issues.
Final justification
The rebuttal clarifies the scope of the claims and provides useful robustness and sensitivity analyses. However, the evaluation still does not establish robustness under genuinely sparse or monocular input, substantial pose errors, severe occlusion, disappearance/reappearance, or crowded interactions. I therefore maintain my original rating of 4.
Response to Reviewer 4Xm7
We sincerely thank the reviewer for identifying important practical and conceptual boundaries. We added input-robustness, motion-state, and gate-sensitivity evaluations and will narrow the claims accordingly.
W1 & Q1: Sparse views, monocular input, and noisy poses
PhyMo exhibits only minor performance degradation under the tested sparse-view setting (8 instead of 10 cameras) and modest camera-pose noise, and the motion-confidence gate shows no evident instability as deformation accuracy decreases. We do not claim monocular generalization because depth, camera motion, deformation, and occlusion become jointly ambiguous with a single camera.
Setup. We retrain PhyMo on Laptop and Ballon using 8 of 10 cameras and pose perturbations of 0.5° rotation and 0.5% camera-radius translation, comparing each result with its clean-input counterpart. Given the rebuttal time limit, we additionally evaluate FreeGave as a representative strong baseline with a closely matched reconstruction-and-prediction setting. Using PhysInOne particle-trajectory ground truth, we report the centroid-trajectory RMSE of each segmented dynamic object.
Each cell reports PSNR / Traj. RMSE;
Observations. The results show that PhyMo preserves both reconstruction and motion accuracy under moderate perturbations and remains better than FreeGave. Thus, the gate remains stable rather than opening globally or converging to a near-static shortcut. On Laptop, the trajectory metric and qualitative comparison show that PhyMo follows the Laptop's descent, whereas FreeGave converges to an incorrect motion. On Ballon, the self-comparison measures degradation from clean input, while the additional baseline comparison tests relative rendering and trajectory robustness. Together, these results indicate that inaccurate input geometry does not destabilize the gate.
W2 & Q2: Difficult and failed cases
Yes. We selected three complex interaction scenes from PhysInOne's DORIS fluid data as explicit failure cases analysis and report full-resolution reconstruction metrics. Cake Pouring contains a thin stream that contacts and accumulates on a cake; Burger Sauce forms a moving sheet and multiple drips over a burger; Gel Collapse undergoes large deformation and spreads around supporting utensils. Across all three, PhyMo recovers coarse appearance but loses fine interfaces during material transport and large deformation, clearly delineating the current boundary.
Additional qualitative figures cannot be included in the rebuttal, so we describe the observed failure modes here and will add the corresponding visualizations to the revised paper.
Observations. The failure modes are visually distinct: Cake Pouring smooths the rippled accumulation at impact; Burger Sauce misses the later thin sheet and dripping branches; and Gel Collapse blurs the transparent boundary, surface ridges, and utensils visible through the gel.
These results mark a modeling boundary. PhyMo enforces continuous kinematic states but neither models forces nor infers material parameters such as Young's modulus or viscoelastic coefficients, so it cannot determine complex contact or constitutive responses. We therefore narrow the claim to continuous, kinematically consistent motion.
This is also a shared challenge for Gaussian Splatting-based dynamic methods: persistent discrete primitives struggle with fluid transport, thin sheets and filaments, transparency, and topology changes. The matched FreeGave results show the same overall difficulty rather than a PhyMo-specific failure.
W3 & Q3: Scope of "physical dynamics"
It is true that our use of the term physical dynamics is too broad and technically inaccurate for the current formulation. We will correct this distinction clearly.
Specific Revisions. In the main text and figure captions, we will replace learning physical dynamics with learning continuous motion evolution or learning kinematically consistent motion, and replace physically plausible prediction with kinematically consistent prediction where the claim is supported by position-velocity-acceleration consistency. We will apply this correction consistently in the Abstract, Introduction, Method, Experiments, Conclusion, and Limitations, and explicitly list the unmodeled physical causes and parameters as a limitation.
Further Clarification. This correction does not change the contribution. PhyMo addresses two under-constrained steps in visual motion learning: recovering a faithful deformation trajectory, and recovering continuous, mutually consistent position-velocity-acceleration states on top of that trajectory. We additionally include direct evaluation of trajectory, velocity, and acceleration on PhysInOne using the available ground-truth trajectories and their temporal derivatives. This directly validates the recovered motion states beyond rendered images and per-frame Chamfer Distance.
Moving from kinematics to dynamics—that is, from estimating how motion states evolve to identifying the physical causes of that evolution—remains a broader open problem for the visual-physics community and is still at an early stage. The central difficulty is that images reveal the consequences of motion, while the underlying causes—such as force, mass, contact, friction, and material response—remain latent and coupled. Even in a simple Newtonian setting, an observed acceleration alone cannot separately identify force and mass; contact and material interactions introduce additional unknowns. Existing approaches therefore often rely on prescribed governing equations, known physical systems, or restricted object, material, and interaction classes, which limits their generality. A broader future direction is to bridge reliable motion-state estimation with identifiable modeling of the underlying physical causes. We will present this as future work, not as a capability of the current method.
W4 & Q4: Gate bootstrapping and sensitivity
The gate remains stable across the deformation magnitudes and hyperparameter ranges evaluated on PhysInOne. β and q_min have little effect, while τ introduces only moderate and predictable sensitivity. The gate also remains selective when deformation is inaccurate early in training rather than opening prematurely.
Setup. We evaluate one shared gate configuration across all six PhysInOne scenes, which span local-motion magnitudes from 0.064 to 0.390 m. We further vary τ, β, and q_min one at a time and report trajectory RMSE and PSNR:
Observations. The narrow trajectory-RMSE and PSNR ranges show that the gate is robust across the evaluated deformation amounts and parameter settings. Changing β or q_min has little effect on motion or rendering quality. A stricter τ delays subtle-motion activation and therefore produces a larger, but still moderate, variation.
Why the gate remains stable. The sensitivity results establish final performance robustness, while the controlled ablation and training dynamics in the Appendix explain its source. The following Sandwich ablation isolates per-Gaussian activation and local-motion confidence:
The full local-motion gate achieves the best rendering and geometric accuracy. Moreover, Appendix training dynamics show that activation remains limited until reliable motion is established, after which increasing activation coincides with decreasing CD and rendering loss. Canonical warm-up, gradual temporal expansion, stop-gradient, and continuous confidence updates therefore prevent early deformation errors from irreversibly opening the appearance shortcut.