- Rating
- 2
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 2
Read review
Summary
This paper introduces two main contributions: a dataset called MIST and a method called PRISM. MIST is a public dataset for through-obstacle human sensing using mmWave radar, providing paired clear-view and occluded data with synchronized LiDAR point clouds as ground truth. PRISM is a conditional latent diffusion model which leverages a skeleton-guided conditioning mechanism. It first estimates skeleton joints from the sparse input and then uses these joints, along with coarse body geometry and action class embeddings, to guide the diffusion-based denoising process. The authors demonstrate that the high-quality reconstructions from PRISM lead to substantial performance gains in downstream tasks like human activity recognition, pose estimation, and rehabilitation assessment.
Strengths and weaknesses
Strengths
- The MIST dataset is a valuable benchmark for the community of through-obstacle human point cloud reconstruction with paired data and dense ground truth. The inclusion of multiple modalities (mmWave, LiDAR, Depth, RGB) and diverse action classes makes it a valuable resource for future research.
- The PRISM provides a strong anatomical constraint that helps the model overcome the inherent ambiguity and extreme sparsity of mmWave inputs, a problem where prior generative and completion methods fail. The architecture is well-designed and justified.
- The evaluation on three distinct downstream tasks (HAR, HPE, Rehab Assessment) demonstrates that the improved reconstruction quality is not merely cosmetic but translates into tangible benefits for practical applications, which is the ultimate goal of such a system.
Weaknesses
- While MIST is a great first step, its scale is somewhat limited. With only 8 subjects collected in a single controlled laboratory environment, the generalization of models trained on MIST to diverse real-world scenarios (different body morphologies, ages, environments) remains an open question.
- The entire framework, from data collection to the model itself, is designed for a single subject. This is a significant simplification, as many target scenarios (e.g., hospitals) involve multiple people. Extending this work to multi-person scenes with occlusions and overlapping radar returns would be non-trivial and is a major limitation of the current scope.
- PRISM requires 200 reverse diffusion steps, resulting in a per-frame latency exceeding 1 second on a single GPU. This is too slow for many real-time applications, such as fall detection or interactive rehabilitation feedback. The current model's practicality is limited by its computational cost at inference time.
Questions
- The current work excels in a controlled, single-person setting. However, a key leap for real-world deployment involves handling both multi-person scenarios and environmental variations simultaneously. Consider a scenario with two individuals interacting behind a wall. The input would be a single, extremely sparse point cloud containing mixed returns from both people. How would the PRISM, which is designed to be conditioned on a single skeleton, resolve this fundamental ambiguity?
- Regarding the barrier material, MIST uses only wooden boards. How do you expect PRISM to perform with other common building materials like concrete, brick, or metal-laced drywall, which have drastically different electromagnetic properties? Would the model require complete retraining for each new material?
- The paper focuses on point cloud reconstruction. Have you considered reconstructing a parametric body model (e.g., SMPL) directly? This could offer benefits like direct access to pose parameters and might be a more constrained, and potentially easier, output space for the diffusion model.
Limitations
yes
Paper formatting concerns
no
Final justification
While I acknowledge the authors' diligent efforts in their rebuttal and the positive aspects of this work highlighted by myself and other reviewers, a deeper consideration of the paper's core limitations and the proposed solutions has led me to conclude that the work, in its current form, does not meet the standards for publication at NeurIPS. My primary concern stems from the fundamental disconnect between the highly controlled, single-person experimental paradigm and the intractable complexities of real-world, multi-person scenarios, a gap which I believe the authors' proposed solutions do not credibly bridge.
The "Upstream Separation" Assumption is Fundamentally Flawed in the Context of Through-Obstacle Sensing.
The authors' central argument for extending their work to multi-person scenarios hinges on the existence of an "upstream separation module" (Response C.1.2) that would isolate person-specific point clouds before feeding them to PRISM. This assumption is overly optimistic and sidesteps the most critical challenge of through-obstacle wireless sensing: pervasive and non-separable multipath propagation and signal mixing. In a through-obstacle environment, especially with multiple subjects, the received signal is a complex superposition of direct returns, returns that have bounced off multiple subjects, and returns that have reflected off static objects (walls, furniture) before and after interacting with subjects. The authors' suggestion of using methods like spatial-Doppler clustering (e.g., DBSCAN) is only effective under ideal, line-of-sight conditions where subjects are well-separated in range, velocity, and angle. Behind a barrier, signal attenuation drastically lowers the SNR, and multipath effects create ghost points that inextricably link the subjects. Two individuals interacting or even standing in proximity will create a single, tangled set of returns in the radar's raw data cube. There is no known, reliable method to disentangle these mixed-signal returns into person-specific point clouds, especially when the ground truth (number of people, their locations) is unknown.
The Single-Scene, Single-Material Evaluation Severely Limits the Claimed Contribution.
The work's empirical validation is confined to a single laboratory room with a single, electromagnetically simple barrier material (wood). While this provides a valuable proof-of-concept, it fails to address the profound impact of environmental diversity on mmWave sensing. The authors suggest (in response to another reviewer) that calibration might be needed for a new scene. This is an understatement. Every new environment introduces a unique multipath signature. The reflections from walls, floors, and clutter fundamentally alter the structure of the received point cloud in ways that are far more complex than a simple increase in sparsity. Zero-shot generalization to a new scene is highly unlikely to succeed without extensive, scene-specific modeling or data. By limiting the evaluation to one scene, the paper avoids this critical issue, thereby presenting an incomplete and potentially misleading picture of the method's robustness.
The Scope of Contribution is Therefore Narrower than Implied.
In summation, this paper presents an elegant solution to a simplified, sanitized version of the through-obstacle human sensing problem. The core claims of the paper rest on the implicit assumption that the chaotic, mixed-signal reality of multi-person, multi-path environments can be cleanly factored into a series of isolated, single-person problems. My analysis, supported by the fundamental principles of wireless sensing, indicates that this assumption is not valid. The authors' proposed path to overcoming this limitation is not convincing and glosses over a problem of immense difficulty.
While the MIST dataset is a useful asset for the highly specific task it represents, and the PRISM model is cleverly designed, the foundational limitations regarding multi-person ambiguity and environmental generalization prevent this work from constituting a significant and robust advance for the field at this time. Therefore, despite its strengths in execution on a constrained problem, I must recommend rejection. The work requires a more fundamental reconceptualization of the problem itself before it can claim to offer a viable solution for real-world scenarios.
Response to Reviewer g44F
We thank the reviewer for the constructive questions regarding MIST and its generalization, and provide our responses below.
Q C.1 "Consider a scenario with two individuals interacting behind a wall. … single skeleton, resolve this fundamental ambiguity?"
We thank the reviewer for raising this important and practically relevant question.
C.1.1 Why the current model cannot resolve the ambiguity. PRISM does not directly resolve the ambiguity of mixed multi-person returns. It is designed as a preprocessing and representation-enhancement module before downstream tasks: given an incomplete point cloud belonging to a single person, it reconstructs a more structured and temporally coherent human point cloud for subsequent recognition or analysis. Accordingly, its current input and skeleton condition both assume one person, and applying it directly to a mixed two-person point cloud could produce an invalid skeleton and reconstruction.
C.1.2 Where separation belongs. Multi-person separation should therefore be performed upstream of PRISM. For example, radar returns could first be separated using spatial–Doppler clustering such as DBSCAN, beamforming toward different regions of interest, and person identification and tracking to maintain identities over time. PRISM would then be applied independently to each person-specific point cloud. Although this separation process would further reduce the already sparse number of points available for each individual, compensating for such degradation is precisely the role of PRISM: it can reconstruct a more complete and structured representation from the separated but incomplete returns. Thus, PRISM is not itself a multi-person separation model, but it could serve as a downstream completion module within a multi-person sensing pipeline. Cases in which two people remain inseparable in range, angle, and motion would still require additional sensing cues or a dedicated joint multi-person model, and we will clarify this limitation in the revised manuscript.
Q C.2 "Regarding the barrier material … Would the model require complete retraining for each new material?"
We thank the reviewer for this question. Retraining is not required, and we explain why below.
C.2.1 Why a new material is not a new task. Unlike many Doppler-based mmWave sensing methods, PRISM does not directly observe or model the barrier itself. Its input consists only of the human point cloud remaining after the radar signal passes through the barrier. Based on our previous tests using glass as a barrier, changing the barrier material mainly affects the sparsity of the reflection points, the noise level, and the spatial distribution. Since PRISM is conditioned on the resulting point set rather than on a material label, complete retraining should not be necessary when a new material produces observations within the degradation range represented by MIST. The OL0–OL2 settings and zero-shot experiments further demonstrate PRISM’s robustness to increasingly sparse inputs.
Retraining or adaptation may become necessary only when the new barrier causes a substantially larger domain shift than the three existing OL levels—for example, when excessive attenuation, highly non-uniform thickness, severe multipath, or spatially biased transmission leaves an extremely sparse and uneven point cloud. In such cases, the input distribution may fall outside the range encountered during training. Even then, complete retraining for every material may not be required; calibration or limited fine-tuning using samples from the new condition could be sufficient. If almost no valid human reflections survive the barrier, however, the limitation arises at the sensing stage and cannot be addressed by retraining PRISM alone. We will clarify this conditional cross-material generalization and its boundaries in the revised Limitations section.
Q C.3 "Have you considered reconstructing a parametric body model … a more constrained, and potentially easier, output space for the diffusion model."
We appreciate this insightful suggestion. Directly reconstructing SMPL parameters is a promising alternative.
C.3.1 Why we reconstruct point clouds. Our primary consideration is supervision. MIST provides synchronized dense LiDAR point clouds as ground truth, allowing PRISM to learn reconstruction directly in the observed geometric space. Supervising an SMPL output would first require fitting SMPL to the LiDAR data. This would introduce fitting errors and make the benchmark partly dependent on the annotation pipeline. Point clouds also impose fewer assumptions about body topology and can naturally retain partial observations, loose clothing, carried objects, and assistive devices.
C.3.2 Compatibility with downstream mmWave tasks. Although SMPL is valuable for pose-related applications, most conventional mmWave pipelines operate directly on lightweight point-cloud representations. These representations are widely used for person identification, trajectory tracking, and human activity recognition. Point clouds preserve the radar-native data format, avoid additional mesh fitting or rendering, and can be processed efficiently by existing radar models. Since PRISM is intended as a preprocessing and data-enhancement component for downstream tasks, producing a denser and more structured point cloud provides more direct compatibility with current mmWave pipelines. We therefore selected point-cloud reconstruction as the primary output. However, we believe that SMPL reconstruction, either predicted directly or fitted from the completed point cloud, remains a promising complementary direction.
Q C.4(Weaknesse1) "While MIST is a great first step, its scale is somewhat limited … remains an open question."
C.4.1 Scale in context. We agree that the current number of participants and the controlled laboratory setting limit the demonstrated generalization of MIST. In particular, the original cohort does not fully represent the diversity of ages, body morphologies, mobility conditions, and real-world environments that may be encountered in practical healthcare applications. We will state this limitation more explicitly in the revised manuscript.
C.4.2 Cohort expansion. We have already begun expanding the dataset to improve its demographic and subject-level diversity. The current cohort has increased from 8 to 15 participants and includes greater variation in age, gender, and body morphology. We aim to include 20 participants in the released version of MIST. Current data collection covers indoor rooms and open spaces. We further plan to collect data in corridors and real healthcare environments to capture more realistic variations in layout, clutter, and sensing conditions.
Q C.5(Weaknesse2) "The entire framework, from data collection to the model itself, is designed for a single subject. … the current scope."
C.5 As discussed in C.1 and C.2, PRISM is designed to enhance a separated single-person point cloud rather than resolve mixed multi-person returns directly. It can therefore serve as an intermediate completion module after upstream person separation and tracking. We have also established collaboration with a local healthcare and eldercare organization and plan to collect data in real clinical environments with a broader range of ages, body morphologies, and mobility conditions to support future deployment studies.
Q C.6(Weaknesse3)"PRISM requires 200 reverse diffusion steps … limited by its computational cost at inference time."
We agree that the submitted 200-step configuration is too slow for sustained real-time use. However, it was selected as the highest-quality setting rather than a fixed requirement of PRISM. We therefore add the following latency and reconstruction-quality trade-off.
C.6.1 Sampling-step trade-off. Inference latency decreases approximately linearly with the number of diffusion steps, and the same trained checkpoint can be used without retraining. Reducing the sampler from 200 to 20 steps lowers latency from 879.9 ms to 93.0 ms per frame and increases throughput from 1.14 to 10.75 fps, while COV-CD decreases by at most 3.3%. A 10-step setting reaches 20.32 fps with a larger quality reduction of 5.3%. These results show that the 200-step latency is not intrinsic to the model and that the operating point can be selected according to the downstream task.
Table C.6 (new). Latency and quality against the number of sampling steps.
C.6.2 End-to-end latency. The measurement covers the diffusion stage together with the conditioning it consumes. It excludes SkelKD, which produces the conditioning skeleton upstream, and it excludes radar preprocessing. Reducing the number of steps therefore shortens the diffusion term only. The upstream stages are a fixed cost that no change of sampler removes, and they set the floor of the end-to-end budget, which we will report per stage.
C.6.3 Practical operating points. The radar operates at 10 fps, which is matched by the 20-step configuration. This setting is therefore suitable for sustained reconstruction in interactive rehabilitation, whereas fall detection can additionally use event-triggered reconstruction over a one- to two-second temporal window. We will report downstream performance at reduced step counts and clarify that 200 steps represent the maximum-fidelity configuration, while 20 steps provide the recommended real-time setting.