acceptodds
Published as a conference paper at NeurIPS 2026

A Steerable Deep Network for Model-Free Diffusion MRI Registration

Gianfranco Cortés, Xiaoda Qu, Baba C Vemuri

Abstract

Nonrigid registration is vital to medical image analysis but remains challenging for diffusion MRI (dMRI) due to its high-dimensional, spatio-angular dependence. We present a novel, geometric deep learning framework for \it model-free, nonrigid registration of raw dMRI data. The dMRI registration problem is formulated in the native spatio-angular acquisition space, which exhibits a natural symmetry to the group of 3D roto-translations, denoted by . A by-product of this design choice is freedom from having to augment the data with roto-translated versions of itself. Our second novelty is the loss function formulation, based on the maximum mean discrepancy (MMD) loss used to compare two probability density functions. We apply this loss in the Fourier space, where it becomes the well-known weighted sum-of-squared differences (SSD) loss with the weights being the Fourier transform of a reproducing kernel Hilbert space (RKHS) kernel. Experimental results on HCP and OASIS-3 clinical-grade dMRI data demonstrate competitive performance compared to SOTA approaches, with the added advantage of bypassing the overhead for estimating derived representations. This work establishes a foundation for data-driven, geometry-aware dMRI registration directly in the acquisition space.

Keywords:
Atlanta, Main Track

Reviews

Among:
Shape:
123456this paper, Bottom 17%
Figure 1. Mean review rating of the reviewed papers at NeurIPS 2026. This paper averages 4.00 over 3 reviews, above 17% of the others.
Reviewer_zT1dOpenReview ↗
Rating
4
Clarity
3
Confidence
4
Originality
3
Quality
2
Significance
2
Read review
Summary

This work addresses the central challenge of nonrigid diffusion MRI registration by proposing a model-free framework that operates directly in the native spatio-angular acquisition domain, denoted by (p, q). The paper formulates dMRI registration using the vector-bundle structure of (PQ), restricts feasible alignments to shell-preserving automorphisms, and instantiates this formulation with an SE(3)-equivariant U-Net that predicts both a spatial diffeomorphism and a spatially varying fiber-rotation field. The paper also introduces a self-supervised MMD objective between ensemble average propagators (EAPs), which reduces in practice to a weighted SSD-like loss over signal attenuations in (q)-space. Experiments on HCP and OASIS-3 compare the method with classical and learning-based dMRI registration baselines.

Strengths and weaknesses

Strengths

  • The paper provides a clear and mathematically motivated formulation of dMRI registration on (PQ). The use of vector-bundle geometry gives a principled way to distinguish spatial coordinates from diffusion-gradient directions, and the shell-preserving constraint T(p)∈SO(3)T(p) \in SO(3) is physically well motivated.

  • The proposed network design is well aligned with the theoretical formulation. The use of SE(3)-steerable convolutional layers, Wigner-D matrices, spatial diffeomorphisms, and spatially varying fiber rotations is coherently connected to the desired equivariance properties of the registration operator.

  • The paper evaluates the method on both research-grade HCP data and more clinically challenging OASIS-3 data. The use of both white-matter bundle segmentations and hippocampal segmentations provides some diversity in evaluation targets.

  • The method avoids committing to a particular derived diffusion representation, such as DTI, fODF, or TOM, at the registration stage. This is an appealing direction when registration is intended as an intermediate preprocessing step before downstream analyses whose optimal diffusion representation may not be known in advance.

Weaknesses

  • The main empirical message is that the proposed method is competitive, not that it is clearly superior to representation-based pipelines. On HCP, DDMReg achieves the best Dice and Hausdorff distance, while the proposed method is close but not best. On OASIS-3, mrregister slightly outperforms the proposed method. These results are encouraging, but they do not yet demonstrate a consistent practical advantage of raw-signal registration over strong derived-representation baselines.

  • The ablation study is too limited for a method whose novelty depends heavily on specific architectural and geometric choices. Apart from a small MMD-vs.-MSE loss comparison, the paper does not isolate the contributions of SE(3)-equivariance, explicit learned fiber rotation, the independent rotation field ω\omega, shell preservation, the Wigner-D deformation operator, or the choice of spherical harmonic bandlimit. In particular, it would be important to compare against variants where T(p)T(p)is derived from DϕD\phi, as in classical reorientation, and where the learned rotation field is removed.

  • The fairness of baseline tuning is unclear. The proposed method uses Bayesian hyperparameter optimization for at least some regularization parameters, but the paper does not clearly state whether the baselines were given comparable tuning budgets. The exact tuned hyperparameters, search spaces, validation criteria, and sensitivity analyses are missing.

  • The computational tradeoffs are underreported. Although the paper states the GPU setting and notes that the data were spatially and angularly downsampled due to memory constraints, it does not report training time, inference time, peak memory, parameter count, or scaling behavior with spatial resolution, number of shells, and number of gradient directions.

  • The qualitative evidence is too thin, and some figure-level claims are overstated. Figure 3 shows a visually plausible improvement in one highlighted region, but this is not sufficient to support the claim that SE(3)-equivariance preserves white-matter fiber tracts during warping. That claim would require quantitative tract-continuity, orientation-consistency, or equivariance-error analyses, preferably across many subjects and bundles.

Questions
  • Can the authors provide ablations that isolate the contribution of SE(3)-equivariance and explicit fiber rotation? Useful variants would include a non-equivariant U-Net, a model with ω=0\omega = 0, a model where T(p)T(p) is determined by the local Jacobian DϕD\phi, and a model with the MMD loss replaced by standard MSE or NCC-style losses.

  • Can the authors quantify the computational cost and practical tradeoffs relative to baselines? Please report training time, inference time per pair, peak GPU memory, model size, and scaling with spatial resolution, number of gradient directions, and number of shells. It would also be helpful to clarify whether full-resolution HCP data can be processed without downsampling.

  • Can the authors evaluate the geometry-specific claims more directly? Figure 3 alone does not substantiate the tract-preservation claim.

  • Were all baselines tuned under comparable validation protocols and computational budgets? Please provide baseline hyperparameter settings, tuning ranges, and validation selection criteria.

  • Can the authors provide statistical tests or paired confidence intervals for the main comparisons? The reported differences between the proposed method, DDMReg, MVVSReg, and mrregister are small in several cases, so it is difficult to assess whether the observed differences are meaningful.

Limitations

No. The paper mentions only one limitation in Section Conclusion, several others should be discussed explicitly.

Paper formatting concerns

no

Final justification

Thanks for the explanation and justification, I will maintain the score.

1 comment

We thank the reviewer for their thoughtful and constructive evaluation. We are encouraged that they found the proposed formulation to be clear and mathematically motivated, the network design to be well aligned with the underlying theory, and the model-free approach to be an appealing direction for diffusion MRI registration.

We note that all new experiments reported in this rebuttal were conducted on the native-resolution HCP diffusion images, without the spatial or angular downsampling used in the original submission. These experiments became computationally feasible after we obtained access to higher-memory NVIDIA B200 GPUs following the submission deadline.

Below, we address each of the reviewer’s questions and concerns.

“The qualitative evidence is too thin, and some figure-level claims are overstated.”

We agree that Fig. 3 does not support a general tract-preservation claim. We have revised the caption to describe the figure more narrowly as a qualitative example of improved local tract continuity after registration, without attributing this effect specifically to SE(3)-equivariance.

“Can the authors provide ablations that isolate the contribution of SE(3)-equivariance and explicit fiber rotation? Useful variants would include a non-equivariant U-Net, a model with ω=0\omega=0, a model where T(p)T(p) is determined by the local Jacobian DϕD\phi, and a model with the MMD loss replaced by standard MSE or NCC-style losses.”

We thank the reviewer for these thoughtful suggestions. Regarding the similarity loss, the manuscript already includes a small comparison of MMD against a standard MSE loss, in which MMD achieved a higher Dice score. We agree that a more complete comparison, including NCC-style losses, would be valuable.

We are currently completing experiments comparing the learned rotation field against both ω=0\omega=0 and the Jacobian-derived rotation T=R(Dφ)T=\mathfrak{R}(D\varphi). Because these variants require retraining separate models, the experiments are still in progress at this time. A controlled non-equivariant U-Net ablation has not yet been completed, so the present rebuttal does not fully isolate the contribution of SE(3)\mathrm{SE}(3)-equivariance. Note, however, that SE(3)\mathrm{SE}(3)-equivariance is a requirement if one wishes to enforce consistency under roto-translations of PQ\mathbb{PQ}-space, thereby respecting its intrinsic geometry. We will report the complete quantitative results of the ongoing rotation ablations in this discussion as soon as they become available.

“Can the authors quantify the computational cost and practical tradeoffs relative to baselines?”

We evaluated end-to-end wall-clock runtime using 10 HCP test subjects, from which 90 ordered fixed-moving pairs were formed. Preprocessing runtimes are reported as an average over the 10 subjects, while registration runtimes are reported as an average over the 90 fixed–moving pairs. All runtimes are given in seconds. To ensure a fair comparison, all multithreaded preprocessing steps (e.g., MRtrix3's dwi2response and dwi2fod for fODF fitting) were assigned 4 CPU cores, while GPU-accelerated operations, including inference, were executed on a single NVIDIA B200 GPU.

MethodAtt.SHTDTIFAfODFPeaksTOMSRDEff. Prep. †Reg.Total ‡
Ours0.570.04------------0.614.765.37
DDMReg----51.021.24469.3277.3263.76--610.401.09611.49
MVCReg--------469.32----0.47469.7911.57481.36
mrregister--------469.32------469.32852.431321.75

† Eff. Prep. Sum of all preceding entries in the row, except for DDMReg as described below.

‡ Total. End-to-end wall-clock time per image pair (Eff. Prep. + Reg.).

The abbreviations used in the breakdown above are defined below.

Abbrev.MeaningAbbrev.Meaning
Att.Attenuation computation (E=S/S0E=S/S_0)PeaksPeak extraction
SHTSpherical harmonic fit (E^\widehat{E})TOMTract orientation map computation
DTIDiffusion tensor fitSRDSquare root density parameterization
FAFractional anisotropy computationReg.Registration/inference
fODFFiber orientation distribution fitEff. Prep.Effective pair preparation time

To avoid overstating preprocessing overhead, we used an optimistic parallel-execution model. For every method, moving and fixed images were assumed to be preprocessed concurrently, while dependent operations within each image remained sequential. DDMReg was given the additional benefit of assuming that its independent DTI$\rightarrow$FA (SlicerDMRI) and fODF$\rightarrow$Peaks$\rightarrow$TOM (MRtrix3 + TractSeg) branches also execute concurrently, so its effective preparation time is determined by the slower branch. For our method, attenuation computation precedes spherical harmonic fitting. For MVCReg, fODF fitting (MRtrix3) precedes SRD parameterization, whereas for mrregister, preparation only includes fODF fitting (MRtrix3). Our method achieves the lowest end-to-end wall-clock time among the compared methods, requiring only 5.37 s per image pair, representing an 89.6× speedup over the next-fastest method (MVCReg).

“Can the authors evaluate the geometry-specific claims more directly?”

To directly evaluate the geometry-specific claims beyond the qualitative example in Fig. 3, we performed an additional analysis on the 90 HCP fixed–moving test pairs used in the original study. We evaluated our method together with a representative selection of baselines. This analysis provides both updated macrostructural metrics (bundle Dice and bundle Hausdorff distance) and new microstructural metrics (ACC, peak error, and tensor OVL) to evaluate local orientation consistency.

MethodBundle Dice ↑Bundle HD (mm) ↓ACC ↑Peak error (°) ↓Tensor OVL ↑
Unregistered (reference)0.5567 ± 0.064313.22 ± 2.410.42 ± 0.0333.81 ± 1.650.47 ± 0.03
Ours0.7930 ± 0.01159.96 ± 0.820.60 ± 0.0123.25 ± 0.350.65 ± 0.01
DDMReg0.7848 ± 0.043510.42 ± 1.530.57 ± 0.0227.07 ± 1.140.58 ± 0.02
mrregister0.7879 ± 0.01629.81 ± 0.870.59 ± 0.0123.80 ± 0.460.63 ± 0.01

We report three complementary microstructural metrics, with voxelwise values averaged within the fixed image's white-matter mask. First, the fODF angular correlation coefficient (ACC) measures agreement between the warped and fixed fODFs. We then extracted peaks from both fODFs, matched corresponding peaks, and measured their angular error (Peak error). Finally, as suggested by Reviewer Qkm2, we computed the tensor overlap (Tensor OVL) due to Basser & Pajevic (2000), which measures the overlap of corresponding eigenvalue–eigenvector pairs between the warped and fixed diffusion tensors. For each metric, we first obtained one value per fixed-moving pair and report the mean ± standard deviation across the 90 pairs. Across ACC, peak error, and tensor OVL, our method consistently achieved the strongest performance, providing direct quantitative support for improved local diffusion geometry alignment.

“Were all baselines tuned under comparable validation protocols and computational budgets? Please provide baseline hyperparameter settings, tuning ranges, and validation selection criteria.”

We will clarify the tuning protocol. Official checkpoints were used for DDMReg, SynthMorph, and multiGradICON. VoxelMorph, MVCReg, and MVVSReg were trained on the same HCP split and tuned using Bayesian hyperparameter optimization with the same number of trials as our method. All trained methods, including ours, were selected by validation loss. We have reported the search spaces and selected hyperparameters in the revised manuscript's appendix.

“Can the authors provide statistical tests or paired confidence intervals for the main comparisons? The reported differences between the proposed method, DDMReg, MVVSReg, and mrregister are small in several cases, so it is difficult to assess whether the observed differences are meaningful.”

We performed paired comparisons across the 90 fixed–moving HCP test pairs to quantify the observed performance differences. For each registration pair, we computed the difference between our method and the corresponding baseline and report the mean paired difference together with its 95% confidence interval.

MetricComparisonMean paired difference95% CI
Bundle Dice ↑Ours − DDMReg+0.0082[+0.0010, +0.0154]
Bundle Dice ↑Ours − mrregister+0.0051[+0.0016, +0.0087]
Bundle HD (mm) ↓Ours − DDMReg−0.46 mm[−0.75, −0.17]
Bundle HD (mm) ↓Ours − mrregister+0.15 mm[−0.01, +0.31]

In the paired analysis, our method achieved significantly higher bundle Dice than both baselines and significantly lower Hausdorff distance than DDMReg. Although mrregister had a slightly lower mean Hausdorff distance, that difference was not statistically significant.

“The paper mentions only one limitation in Section Conclusion, several others should be discussed explicitly.”

We agree that the limitations discussion is currently narrow. In the revision, we will expand it to discuss the need to assess generalization to additional acquisition protocols and clinical populations beyond those considered in this study.

Reviewer_Qkm2OpenReview ↗
Rating
4
Clarity
3
Confidence
3
Originality
3
Quality
3
Significance
3
Read review
Summary

This paper proposes a non-rigid diffusion MRI registration framework that operates directly on raw diffusion signals. Unlike existing learning-based registration approaches that rely on simplified scalar representations (such as FA maps or structural MRI) or tensor-valued representations (such as DTI), the proposed method is model-free. By utilizing the raw dMRI signal directly, the framework avoids the information loss typically associated with downstream diffusion modeling during the registration process.

Strengths and weaknesses

The paper proposes a registration approach that operates directly on raw diffusion MRI, potentially avoiding the need to commit to a specific derived representation such as Diffusion Tensor Imaging. This is an interesting and potentially valuable direction, as it could preserve more of the underlying signal information and reduce dependence on handcrafted intermediate representations commonly used in diffusion processing pipelines.

However, it is unclear whether the proposed method introduces additional computational cost in terms of training or inference time and memory, which is an important consideration for practical use. Also, the reported results are not clearly superior to existing approaches and maybe that does not need to be the case, but it is not clearly demonstrated in the current evaluation if the method offers other advantages.

If the goal is to position the method as an alternative rather than a direct improvement, a more detailed analysis of the underlying anatomical or fibre-tract alignment would be valuable. Overall, while the idea is interesting, further evidence is needed to better establish its practical benefit and added value over existing approaches.

Questions

Could the authors provide a clear breakdown of the computational overhead introduced by processing the raw dMRI signal rather than a derived representation?

Since the primary conceptual advantage of registering raw dMRI signals is preserving the full richness of the diffusion data, does this translate into better alignment of underlying white matter structures? So maybe running some type of tractography analysis on the fiber bundles or maybe transforming the pre and post-registration volumes into DTIs and calculating the overlap of eigenvalue–eigenvector pairs (OVL) between warped and fixed? I basically would like to see a quantitative result for the underlying fiber orientation (so, not Dice Score or HD).

Given that the proposed framework is not currently performing better than DDMReg for the HCP dataset or the more classical tool mrregister, what is the intended primary use-case for your proposed method? Is it intended as a high-speed alternative, or an alternative? And if an alternative, then why?

Limitations

Yes, the authors have discussed limitations of their work.

Paper formatting concerns

n/a

Final justification

I thank the authors for providing such a good explanation and justification for the concerns I have raised; for this reason I have changed my score to Borderline Accept.

1 comment

We thank the reviewer for their thoughtful and constructive evaluation. We are encouraged that they found the direction of registering raw dMRI directly to be interesting and potentially valuable, and that they recognized its potential to preserve more of the underlying signal information while reducing dependence on handcrafted intermediate representations. We also appreciate their recognition of the originality and clarity of the work.

We note that all new experiments reported in this rebuttal were conducted on the native-resolution HCP diffusion images, without the spatial or angular downsampling used in the original submission. These experiments became computationally feasible after we obtained access to higher-memory NVIDIA B200 GPUs following the submission deadline.

Below, we address each of the reviewer’s concerns.

“Could the authors provide a clear breakdown of the computational overhead introduced by processing the raw dMRI signal rather than a derived representation?”

We evaluated end-to-end wall-clock runtime using 10 HCP test subjects, from which 90 ordered fixed-moving pairs were formed. Preprocessing runtimes are reported as an average over the 10 subjects, while registration runtimes are reported as an average over the 90 fixed–moving pairs. All runtimes are given in seconds. To ensure a fair comparison, all multithreaded preprocessing steps (e.g., MRtrix3's dwi2response and dwi2fod for fODF fitting) were assigned 4 CPU cores, while GPU-accelerated operations, including inference, were executed on a single NVIDIA B200 GPU.

MethodAtt.SHTDTIFAfODFPeaksTOMSRDEff. Prep. †Reg.Total ‡
Ours0.570.04------------0.614.765.37
DDMReg----51.021.24469.3277.3263.76--610.401.09611.49
MVCReg--------469.32----0.47469.7911.57481.36
mrregister--------469.32------469.32852.431321.75

† Eff. Prep. Sum of all preceding entries in the row, except for DDMReg as described below.

‡ Total. End-to-end wall-clock time per image pair (Eff. Prep. + Reg.).

The abbreviations used in the breakdown above are defined below.

Abbrev.MeaningAbbrev.Meaning
Att.Attenuation computation (E=S/S0E=S/S_0)PeaksPeak extraction
SHTSpherical harmonic fit (E^\widehat{E})TOMTract orientation map computation
DTIDiffusion tensor fitSRDSquare root density parameterization
FAFractional anisotropy computationReg.Registration/inference
fODFFiber orientation distribution fitEff. Prep.Effective pair preparation time

To avoid overstating preprocessing overhead, we used an optimistic parallel-execution model. For every method, moving and fixed images were assumed to be preprocessed concurrently, while dependent operations within each image remained sequential. DDMReg was given the additional benefit of assuming that its independent DTI$\rightarrow$FA (SlicerDMRI) and fODF$\rightarrow$Peaks$\rightarrow$TOM (MRtrix3 + TractSeg) branches also execute concurrently, so its effective preparation time is determined by the slower branch. For our method, attenuation computation precedes spherical harmonic fitting. For MVCReg, fODF fitting (MRtrix3) precedes SRD parameterization, whereas for mrregister, preparation only includes fODF fitting (MRtrix3). Our method achieves the lowest end-to-end wall-clock time among the compared methods, requiring only 5.37 s per image pair, representing an 89.6× speedup over the next-fastest method (MVCReg).

“... does this translate into better alignment of underlying white matter structures? ... I basically would like to see a quantitative result for the underlying fiber orientation”

To directly address the reviewer’s request for a quantitative evaluation of the underlying white matter alignment, we performed an additional analysis on the 90 HCP fixed–moving test pairs used in the original study. We evaluated our method together with a representative selection of baselines. This analysis provides both updated macrostructural metrics (bundle Dice and bundle Hausdorff distance) and new microstructural metrics (ACC, peak error, and tensor OVL).

MethodBundle Dice ↑Bundle HD (mm) ↓ACC ↑Peak error (°) ↓Tensor OVL ↑
Unregistered (reference)0.5567 ± 0.064313.22 ± 2.410.42 ± 0.0333.81 ± 1.650.47 ± 0.03
Ours0.7930 ± 0.01159.96 ± 0.820.60 ± 0.0123.25 ± 0.350.65 ± 0.01
DDMReg0.7848 ± 0.043510.42 ± 1.530.57 ± 0.0227.07 ± 1.140.58 ± 0.02
mrregister0.7879 ± 0.01629.81 ± 0.870.59 ± 0.0123.80 ± 0.460.63 ± 0.01

We report three complementary microstructural metrics, with voxelwise values averaged within the fixed image's white matter mask. First, the fODF angular correlation coefficient (ACC) measures agreement between the warped and fixed fODF maps. We then extracted peaks from both fODF maps, matched corresponding peaks, and measured their angular error (Peak error). Finally, as suggested by the reviewer, we computed the tensor overlap (Tensor OVL) due to Basser & Pajevic (2000), which measures the overlap of corresponding eigenvalue–eigenvector pairs between the warped and fixed diffusion tensor images. For each metric, we first obtained one value per fixed-moving pair and report the mean ± standard deviation across the 90 pairs. Our method achieved the best performance across all three microstructural metrics, indicating more accurate alignment of local diffusion geometry than the compared baselines.

“Given that the proposed framework is not currently performing better than DDMReg for the HCP dataset or the more classical tool mrregister, what is the intended primary use-case for your proposed method? Is it intended as a high-speed alternative, or an alternative? And if an alternative, then why?”

We view the proposed method as both a high-speed and a derived-representation-agnostic alternative for deformable dMRI registration. Existing learning-based methods are tightly coupled to specific derived representations (e.g., diffusion tensors, TOMs, or fODFs), requiring users to commit to a particular preprocessing pipeline before registration. Our method instead operates directly on the measured diffusion signal, allowing the registration stage to remain independent of downstream representation choices.

From a practical perspective, the end-to-end wall-clock analysis above demonstrates that this design substantially reduces computational cost by eliminating expensive representation-specific preprocessing. Moreover, the additional native-resolution evaluation shows that our method achieves the highest bundle Dice and the strongest performance across all three microstructural metrics. We therefore view the method as a representation-agnostic alternative that separates registration from a downstream model of diffusion, substantially reduces end-to-end computational cost at inference time, and achieves strong macrostructural and microstructural alignment.

Reviewer_gy17OpenReview ↗
Rating
4
Clarity
3
Confidence
3
Originality
3
Quality
3
Significance
3
Read review
Summary

The paper proposes a geometric deep-learning framework for model-free, nonrigid registration of raw diffusion MRI (dMRI), operating directly in the joint spatio-angular acquisition domain rather than on derived representations (DTI, FA, fODF). The central modeling idea is to treat a dMRI as a section of a vector bundle PQ\mathbb{PQ} (base = scanner space R3\mathbb{R}^3, fibers = qq-space), so that admissible alignments are automorphisms of PQ\mathbb{PQ} and necessarily factor as Φ(p,q)=(φ(p),T(p)q)\Phi(p,q) = (\varphi(p), T(p)q). Imposing shell preservation ∥∣T(p)q∥∣=∥∣q∥∣\||T(p)q\|| = \||q\|| forces T(p)∈SO(3)T(p) \in SO(3), yielding the feasible space AutSO(PQ)\mathrm{Aut}_{SO}(\mathbb{PQ}), which the authors argue strictly enlarges the classical "diff-p" class and recovers it under a locality axiom. The method is an SE(3)SE(3)-equivariant steerable U-Net that outputs a velocity field vv and a Lie-algebra rotation field ω\omega (both type-D1D^1), exponentiated into (φ,T)(\varphi, T) via scaling-and-squaring and T(p)=exp⁡(ω(p)∧)∈SO(3)T(p) = \exp(\omega(p)^\wedge) \in SO(3). Equivariance removes the need for roto-translation augmentation. Training uses a self-supervised MMD loss between ensemble average propagators, which reduces in Fourier space to a kernel-weighted SSD on signal attenuations. Experiments on HCP (TractSeg bundle Dice/HD) and OASIS-3 (hippocampal Dice/HD) report performance competitive with state-of-the-art baselines.

Strengths and weaknesses

Quality: The formulation is principled and the geometric reasoning is sound: the vector-bundle viewpoint cleanly resolves the two pathologies (P1, P2) that a naive Diff+(R3×R3)\mathrm{Diff}_+(\mathbb{R}^3 \times \mathbb{R}^3) domain would admit, and the reduction to Φ(p,q)=(φ(p),T(p)q)\Phi(p,q) = (\varphi(p), T(p)q) with T(p)∈SO(3)T(p) \in SO(3) is well-motivated. My reservations are empirical rather than conceptual. The method never actually outperforms the strongest baseline on either dataset — DDMReg leads on HCP (0.7773 vs. 0.7740) and mrregister leads on OASIS-3 (0.7325 vs. 0.7282) — and the reported error bars overlap in every head-to-head, so "competitive" is accurate but no statistically significant gain is demonstrated. The ablation is thin (a single MMD-vs-MSE Dice pair, 0.7740 vs. 0.7629, no error bars), and despite the stated benefit of "bypassing the overhead" of derived representations, there is no runtime/compute comparison to substantiate it.

Clarity: The paper is well-written and the geometric exposition is careful for an applied registration paper. Fig. 1's taxonomy and the P1/P2 discussion are effective. Two points are underspecified: the multi-shell treatment (the spherical-tensor-field construction is presented per-shell, and how shells are jointly handled is not fully clear), and the "locality axiom" under which AutSO(PQ)\mathrm{Aut}_{SO}(\mathbb{PQ}) collapses to Eq. (2) is stated informally rather than made precise.

Significance: The application need is real: a model-free registration that avoids committing to a diffusion model upfront is genuinely useful for longitudinal/group studies where the downstream model is question-dependent. As the first deep method to register raw dMRI directly in pqpq-space, the work fills an identified gap. The significance is tempered by the fact that the empirical results match rather than exceed existing pipelines, so the practical case rests on the representation-agnostic property rather than on accuracy.

Originality: While the building blocks (SE(3)SE(3)-steerable CNNs, VoxelMorph-style SVF exponentiation, kernel mean embeddings) are individually known, their synthesis — the vector-bundle formalization of dMRI registration, the equivariant prediction of (v,ω)(v, \omega), and the EAP-aligning MMD loss interpreted as Fourier-domain weighted SSD — is what distinguishes the work. By the authors' account, this is the first deep-learning method to register raw dMRI directly in pqpq-space; if accurate, that is a meaningful contribution, and I would encourage the authors to confirm the claim against any concurrent work.

Questions
  1. No win over the best baseline: On both datasets the method is second-best with overlapping error bars. Can the authors provide a statistical significance test (e.g., paired test across the 90 test pairs), and/or identify a regime or metric where raw-signal registration measurably beats derived-representation methods?

  2. The "bypassing overhead" claim: The authors should report end-to-end wall-clock / memory for their method vs. DDMReg and mrregister (including the cost of estimating FA/TOM/fODF for the baselines). The model-free value proposition currently rests on this but is unquantified.

  3. Multi-shell handling: The spherical-tensor-field derivation is per-shell, and the stated limitation requires matching bb-values. How are multiple shells combined in practice, and does T(p)T(p) act consistently across shells?

  4. "Strictly extends" diff-p: Can the authors make the locality axiom precise and state it as a formal claim? The manuscript currently asserts the strict-enlargement and recovery results rather than proving them.

  5. Ablation depth: The authors should expand the MMD-vs-MSE comparison with error bars over the three runs, and ideally an ablation isolating the contribution of the equivariant rotation field ω\omega (i.e., T≡IT \equiv I).

Limitations

Yes

Paper formatting concerns

I did not notice any major issues (Minor: two reference entries contain typos: "mMdical Imaging" in [41] and "Medical Mmage Analysis" in [43]).

Final justification

The rebuttal substantially addressed all five of my concerns: paired confidence intervals establishing significance, orientation-sensitive metrics identifying a regime where raw-signal registration wins, an end-to-end runtime breakdown quantifying the overhead claim, clarified multi-shell handling and locality axiom, and the requested loss and reorientation ablations. I maintain my rating of 4.

1 comment

We thank the reviewer for their thoughtful and constructive evaluation. We are encouraged that they found the vector-bundle formulation to be well-motivated, and the overall synthesis of ideas original. We also appreciate their recognition of the practical value of model-free dMRI registration.

We note that all new experiments reported in this rebuttal were conducted on the native-resolution HCP diffusion images, without the spatial or angular downsampling used in the original submission. These experiments became computationally feasible after we obtained access to higher-memory NVIDIA B200 GPUs following the submission deadline.

Below, we address each of the reviewer's questions and concerns.

“... I would encourage the authors to confirm the claim against any concurrent work.”

We thank the reviewer for raising this point. We re-examined the recent dMRI registration literature and did not identify a concurrent deep-learning method that estimates nonrigid alignments of PQ\mathbb{PQ}-space directly from the diffusion signal. The most recent data-driven approaches instead register derived representations such as DTs (FetDTIAlign), ODFs (ODDRnet), and TOMs (DDTemplate). Nevertheless, to avoid overstating novelty, we will revise the claim to read “to the best of our knowledge.”

“No win over the best baseline: On both datasets the method is second-best with overlapping error bars. Can the authors provide a statistical significance test (e.g., paired test across the 90 test pairs), and/or identify a regime or metric where raw-signal registration measurably beats derived-representation methods?”

We thank the reviewer for this suggestion. To assess whether the observed differences are meaningful, we performed paired comparisons across the 90 fixed–moving HCP test pairs. For each registration pair, we computed the difference between our method and the corresponding baseline and report the mean paired difference together with its 95% confidence interval.

MetricComparisonMean paired difference95% CI
Bundle Dice ↑Ours − DDMReg+0.0082[+0.0010, +0.0154]
Bundle Dice ↑Ours − mrregister+0.0051[+0.0016, +0.0087]
Bundle HD (mm) ↓Ours − DDMReg−0.46 mm[−0.75, −0.17]
Bundle HD (mm) ↓Ours − mrregister+0.15 mm[−0.01, +0.31]

In the paired analysis, our method achieved significantly higher bundle Dice than both baselines and significantly lower Hausdorff distance than DDMReg. Although mrregister had a slightly lower mean Hausdorff distance, that difference was not statistically significant.

Relevant to the reviewer’s second point, we also identified a regime in which raw-signal registration can be evaluated more directly: local diffusion geometry (microstructure) rather than bundle overlap (macrostructure) alone. We therefore performed an additional orientation-sensitive evaluation using ACC, peak error, and tensor OVL. Due to space constraints, we refer the reviewer to the corresponding table in our response to Reviewer zT1d.

“The ‘bypassing overhead’ claim: The authors should report end-to-end wall-clock / memory for their method vs. DDMReg and mrregister (including the cost of estimating FA/TOM/fODF for the baselines).”

We evaluated end-to-end wall-clock runtime using 10 HCP test subjects, from which 90 ordered fixed-moving pairs were formed. Preprocessing runtimes are reported as an average over the 10 subjects, while registration runtimes are reported as an average over the 90 fixed–moving pairs. All runtimes are given in seconds. To ensure a fair comparison, all multithreaded preprocessing steps (e.g., MRtrix3's dwi2response and dwi2fod for fODF fitting) were assigned 4 CPU cores, while GPU-accelerated operations, including inference, were executed on a single NVIDIA B200 GPU.

MethodAtt.SHTDTIFAfODFPeaksTOMSRDEff. Prep. †Reg.Total ‡
Ours0.570.04------------0.614.765.37
DDMReg----51.021.24469.3277.3263.76--610.401.09611.49
MVCReg--------469.32----0.47469.7911.57481.36
mrregister--------469.32------469.32852.431321.75

† Eff. Prep. Sum of all preceding entries in the row, except for DDMReg as described below.

‡ Total. End-to-end wall-clock time per image pair (Eff. Prep. + Reg.).

The abbreviations used in the breakdown above are defined below.

Abbrev.MeaningAbbrev.Meaning
Att.Attenuation computation (E=S/S0E=S/S_0)PeaksPeak extraction
SHTSpherical harmonic fit (E^\widehat{E})TOMTract orientation map computation
DTIDiffusion tensor fitSRDSquare root density parameterization
FAFractional anisotropy computationReg.Registration/inference
fODFFiber orientation distribution fitEff. Prep.Effective pair preparation time

To avoid overstating preprocessing overhead, we used an optimistic parallel-execution model. For every method, moving and fixed images were assumed to be preprocessed concurrently, while dependent operations within each image remained sequential. DDMReg was given the additional benefit of assuming that its independent DTI$\rightarrow$FA (SlicerDMRI) and fODF$\rightarrow$Peaks$\rightarrow$TOM (MRtrix3 + TractSeg) branches also execute concurrently, so its effective preparation time is determined by the slower branch. For our method, attenuation computation precedes spherical harmonic fitting. For MVCReg, fODF fitting (MRtrix3) precedes SRD parameterization, whereas for mrregister, preparation only includes fODF fitting (MRtrix3). Our method achieves the lowest end-to-end wall-clock time among the compared methods, requiring only 5.37 s per image pair, representing an 89.6× speedup over the next-fastest method (MVCReg).

“Multi-shell handling: The spherical-tensor-field derivation is per-shell, and the stated limitation requires matching bb-values. How are multiple shells combined in practice, and does T(p)T(p) act consistently across shells?”

A multi-shell dMRI is represented as a collection of spherical-tensor fields, one per shell. The only sense in which these shells are “combined” is by concatenation along a channel axis, yielding an array of shape [N,C,F,D,H,W], where N is the batch axis, C is the channel axis indexing shells, F is the feature axis indexing spherical harmonic coefficients, and D, H, W are spatial axes. There is one such array for the moving image and one for the fixed image. Thus, all shells are presented jointly as context for the network to predict a single deformation Φ=(φ,T)\Phi=(\varphi,T). The same spatial deformation φ\varphi and the same spatially varying rotation field TT are applied to every shell of the moving image. This uniform action across shells is dictated by the vector-bundle formulation, where TT acts fiberwise and independently of shell radius. We will include this clarification in the revision.

“‘Strictly extends’ diff-p: Can the authors make the locality axiom precise and state it as a formal claim? The manuscript currently asserts the strict-enlargement and recovery results rather than proving them.”

By the “locality axiom,” we mean the additional assumption adopted by diff-p\mathbf{p} approaches that the fiber rotation T(p)T(\mathbf{p}) is completely prescribed by the local spatial deformation φ(p)\varphi(\mathbf{p}), i.e., T(p):=R(Dφ(p))T(\mathbf{p}):=\mathfrak{R}(D\varphi(\mathbf{p})), where R:GL(3)→SO(3)\mathfrak{R}:\mathrm{GL}(3)\rightarrow\mathrm{SO}(3) is some fixed Jacobian-to-rotation map, such as the rotational factor obtained by finite-strain reorientation. Our space of feasible alignments instead allows for arbitrary smooth fields T:R3→SO(3)T:\mathbb{R}^3\to\mathrm{SO}(3). This setting strictly contains the diff-p\mathbf{p} setting, since, for e.g., φ=id\varphi=\mathrm{id}, locality forces T=IT=I, whereas our formulation permits any smooth TT.

This additional freedom has two potential advantages. First, TT is inferred directly from the paired diffusion signals and can exploit spatial context (via the steerable U-Net), whereas a Jacobian-derived rotation is determined solely by the local differential of the deformation and may be sensitive to finite-difference discretization. Second, the framework can model angular correspondence even when little or no macroscopic spatial deformation is needed, as may occur when gross anatomy is already aligned (i.e. φ≈id\varphi \approx \mathrm{id}) but the local diffusion profiles remain differently oriented.

We will explicitly define the locality assumption and add a proof of the strict enlargement in the revision.

“Ablation depth: The authors should expand the MMD-vs-MSE comparison with error bars over the three runs, and ideally an ablation isolating the contribution of the equivariant rotation field ω\omega (i.e., T≡IT\equiv I).”

We agree that expanding the original MMD-vs-MSE comparison across three runs would provide a more complete assessment. We are currently completing the three-run comparison with Dice and Hausdorff distance and have also initiated the requested ablation comparing the proposed model against T≡IT\equiv I and T(p)=polar⁡(Dφ(p))T(\mathbf{p})=\operatorname{polar}(D\varphi(\mathbf{p})). We will report the complete quantitative results in this discussion as soon as they become available and include them in the revision.

“Minor: two reference entries contain typos.”

Thank you for catching these typographical errors. We have corrected both references in the revised manuscript.

Comments on the paper

1 comment
Meta-review

The reviewers generally agree that this paper presents an interesting and principled approach to diffusion MRI registration by operating directly on raw diffusion signals rather than derived representations. The paper formulates registration in the native spatio-angular acquisition space using a geometric vector-bundle framework, instantiates the formulation with an SE(3)-equivariant network that jointly predicts spatial deformation and local fiber rotation, and introduces a self-supervised MMD-based registration objective. The theoretical formulation and geometric motivation are generally viewed as technically sound and constitute the primary strengths of the submission.

However, several important questions remain before the paper can be strongly considered for acceptance. The rebuttal should primarily focus on the following issues:

  1. Clarifying the practical advantages of the proposed framework. While reviewers generally agree that the proposed formulation is elegant, the empirical results are not clearly superior to the strongest existing methods.
  2. Supporting the claimed computational advantages. The paper emphasizes that operating directly on raw diffusion signals avoids the overhead of constructing intermediate representations. Reviewers requested quantitative evidence supporting this claim. Please clarify the computational trade-offs relative to competing methods, including runtime, memory usage, or preprocessing cost where possible, and explain the practical implications of these differences.
  3. Strengthening the empirical analysis. Reviewers requested additional evidence supporting the proposed design choices, including more comprehensive ablations, statistical analysis of the reported improvements, and clarification of the contribution of key components such as the equivariant architecture, learned rotation field, and MMD loss. Please clarify these aspects and discuss the extent to which each component contributes to the overall performance.
  4. Supporting the geometry-specific claims. Several reviewers requested stronger evidence that the proposed framework preserves the underlying diffusion geometry and white matter structure, beyond standard registration metrics. Please clarify what evidence supports these geometry-specific claims and discuss the limitations of the current experimental validation.
  5. Clarifying implementation details and theoretical assumptions. Reviewers requested clarification regarding multi-shell handling, baseline tuning protocols, and several theoretical assumptions underlying the geometric formulation. Please clarify these points to improve reproducibility and strengthen the presentation.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Related papers

Loading the map…

Discussion (0)

Sign in to comment.