- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 2
- Significance
- 2
Read review
Summary
This work addresses the central challenge of nonrigid diffusion MRI registration by proposing a model-free framework that operates directly in the native spatio-angular acquisition domain, denoted by (p, q). The paper formulates dMRI registration using the vector-bundle structure of (PQ), restricts feasible alignments to shell-preserving automorphisms, and instantiates this formulation with an SE(3)-equivariant U-Net that predicts both a spatial diffeomorphism and a spatially varying fiber-rotation field. The paper also introduces a self-supervised MMD objective between ensemble average propagators (EAPs), which reduces in practice to a weighted SSD-like loss over signal attenuations in (q)-space. Experiments on HCP and OASIS-3 compare the method with classical and learning-based dMRI registration baselines.
Strengths and weaknesses
Strengths
-
The paper provides a clear and mathematically motivated formulation of dMRI registration on (PQ). The use of vector-bundle geometry gives a principled way to distinguish spatial coordinates from diffusion-gradient directions, and the shell-preserving constraint is physically well motivated.
-
The proposed network design is well aligned with the theoretical formulation. The use of SE(3)-steerable convolutional layers, Wigner-D matrices, spatial diffeomorphisms, and spatially varying fiber rotations is coherently connected to the desired equivariance properties of the registration operator.
-
The paper evaluates the method on both research-grade HCP data and more clinically challenging OASIS-3 data. The use of both white-matter bundle segmentations and hippocampal segmentations provides some diversity in evaluation targets.
-
The method avoids committing to a particular derived diffusion representation, such as DTI, fODF, or TOM, at the registration stage. This is an appealing direction when registration is intended as an intermediate preprocessing step before downstream analyses whose optimal diffusion representation may not be known in advance.
Weaknesses
-
The main empirical message is that the proposed method is competitive, not that it is clearly superior to representation-based pipelines. On HCP, DDMReg achieves the best Dice and Hausdorff distance, while the proposed method is close but not best. On OASIS-3, mrregister slightly outperforms the proposed method. These results are encouraging, but they do not yet demonstrate a consistent practical advantage of raw-signal registration over strong derived-representation baselines.
-
The ablation study is too limited for a method whose novelty depends heavily on specific architectural and geometric choices. Apart from a small MMD-vs.-MSE loss comparison, the paper does not isolate the contributions of SE(3)-equivariance, explicit learned fiber rotation, the independent rotation field , shell preservation, the Wigner-D deformation operator, or the choice of spherical harmonic bandlimit. In particular, it would be important to compare against variants where is derived from , as in classical reorientation, and where the learned rotation field is removed.
-
The fairness of baseline tuning is unclear. The proposed method uses Bayesian hyperparameter optimization for at least some regularization parameters, but the paper does not clearly state whether the baselines were given comparable tuning budgets. The exact tuned hyperparameters, search spaces, validation criteria, and sensitivity analyses are missing.
-
The computational tradeoffs are underreported. Although the paper states the GPU setting and notes that the data were spatially and angularly downsampled due to memory constraints, it does not report training time, inference time, peak memory, parameter count, or scaling behavior with spatial resolution, number of shells, and number of gradient directions.
-
The qualitative evidence is too thin, and some figure-level claims are overstated. Figure 3 shows a visually plausible improvement in one highlighted region, but this is not sufficient to support the claim that SE(3)-equivariance preserves white-matter fiber tracts during warping. That claim would require quantitative tract-continuity, orientation-consistency, or equivariance-error analyses, preferably across many subjects and bundles.
Questions
-
Can the authors provide ablations that isolate the contribution of SE(3)-equivariance and explicit fiber rotation? Useful variants would include a non-equivariant U-Net, a model with , a model where is determined by the local Jacobian , and a model with the MMD loss replaced by standard MSE or NCC-style losses.
-
Can the authors quantify the computational cost and practical tradeoffs relative to baselines? Please report training time, inference time per pair, peak GPU memory, model size, and scaling with spatial resolution, number of gradient directions, and number of shells. It would also be helpful to clarify whether full-resolution HCP data can be processed without downsampling.
-
Can the authors evaluate the geometry-specific claims more directly? Figure 3 alone does not substantiate the tract-preservation claim.
-
Were all baselines tuned under comparable validation protocols and computational budgets? Please provide baseline hyperparameter settings, tuning ranges, and validation selection criteria.
-
Can the authors provide statistical tests or paired confidence intervals for the main comparisons? The reported differences between the proposed method, DDMReg, MVVSReg, and mrregister are small in several cases, so it is difficult to assess whether the observed differences are meaningful.
Limitations
No. The paper mentions only one limitation in Section Conclusion, several others should be discussed explicitly.
Paper formatting concerns
no
Final justification
Thanks for the explanation and justification, I will maintain the score.
We thank the reviewer for their thoughtful and constructive evaluation. We are encouraged that they found the proposed formulation to be clear and mathematically motivated, the network design to be well aligned with the underlying theory, and the model-free approach to be an appealing direction for diffusion MRI registration.
We note that all new experiments reported in this rebuttal were conducted on the native-resolution HCP diffusion images, without the spatial or angular downsampling used in the original submission. These experiments became computationally feasible after we obtained access to higher-memory NVIDIA B200 GPUs following the submission deadline.
Below, we address each of the reviewer’s questions and concerns.
We agree that Fig. 3 does not support a general tract-preservation claim. We have revised the caption to describe the figure more narrowly as a qualitative example of improved local tract continuity after registration, without attributing this effect specifically to SE(3)-equivariance.
We thank the reviewer for these thoughtful suggestions. Regarding the similarity loss, the manuscript already includes a small comparison of MMD against a standard MSE loss, in which MMD achieved a higher Dice score. We agree that a more complete comparison, including NCC-style losses, would be valuable.
We are currently completing experiments comparing the learned rotation field against both ω=0 and the Jacobian-derived rotation T=R(Dφ). Because these variants require retraining separate models, the experiments are still in progress at this time. A controlled non-equivariant U-Net ablation has not yet been completed, so the present rebuttal does not fully isolate the contribution of SE(3)-equivariance. Note, however, that SE(3)-equivariance is a requirement if one wishes to enforce consistency under roto-translations of PQ-space, thereby respecting its intrinsic geometry. We will report the complete quantitative results of the ongoing rotation ablations in this discussion as soon as they become available.
We evaluated end-to-end wall-clock runtime using 10 HCP test subjects, from which 90 ordered fixed-moving pairs were formed. Preprocessing runtimes are reported as an average over the 10 subjects, while registration runtimes are reported as an average over the 90 fixed–moving pairs. All runtimes are given in seconds. To ensure a fair comparison, all multithreaded preprocessing steps (e.g., MRtrix3's
dwi2responseanddwi2fodfor fODF fitting) were assigned 4 CPU cores, while GPU-accelerated operations, including inference, were executed on a single NVIDIA B200 GPU.mrregister† Eff. Prep. Sum of all preceding entries in the row, except for DDMReg as described below.
‡ Total. End-to-end wall-clock time per image pair (Eff. Prep. + Reg.).
The abbreviations used in the breakdown above are defined below.
To avoid overstating preprocessing overhead, we used an optimistic parallel-execution model. For every method, moving and fixed images were assumed to be preprocessed concurrently, while dependent operations within each image remained sequential. DDMReg was given the additional benefit of assuming that its independent DTI$\rightarrow$FA (SlicerDMRI) and fODF$\rightarrow$Peaks$\rightarrow$TOM (MRtrix3 + TractSeg) branches also execute concurrently, so its effective preparation time is determined by the slower branch. For our method, attenuation computation precedes spherical harmonic fitting. For MVCReg, fODF fitting (MRtrix3) precedes SRD parameterization, whereas for
mrregister, preparation only includes fODF fitting (MRtrix3). Our method achieves the lowest end-to-end wall-clock time among the compared methods, requiring only 5.37 s per image pair, representing an 89.6× speedup over the next-fastest method (MVCReg).To directly evaluate the geometry-specific claims beyond the qualitative example in Fig. 3, we performed an additional analysis on the 90 HCP fixed–moving test pairs used in the original study. We evaluated our method together with a representative selection of baselines. This analysis provides both updated macrostructural metrics (bundle Dice and bundle Hausdorff distance) and new microstructural metrics (ACC, peak error, and tensor OVL) to evaluate local orientation consistency.
mrregisterWe report three complementary microstructural metrics, with voxelwise values averaged within the fixed image's white-matter mask. First, the fODF angular correlation coefficient (ACC) measures agreement between the warped and fixed fODFs. We then extracted peaks from both fODFs, matched corresponding peaks, and measured their angular error (Peak error). Finally, as suggested by Reviewer Qkm2, we computed the tensor overlap (Tensor OVL) due to Basser & Pajevic (2000), which measures the overlap of corresponding eigenvalue–eigenvector pairs between the warped and fixed diffusion tensors. For each metric, we first obtained one value per fixed-moving pair and report the mean ± standard deviation across the 90 pairs. Across ACC, peak error, and tensor OVL, our method consistently achieved the strongest performance, providing direct quantitative support for improved local diffusion geometry alignment.
We will clarify the tuning protocol. Official checkpoints were used for DDMReg, SynthMorph, and multiGradICON. VoxelMorph, MVCReg, and MVVSReg were trained on the same HCP split and tuned using Bayesian hyperparameter optimization with the same number of trials as our method. All trained methods, including ours, were selected by validation loss. We have reported the search spaces and selected hyperparameters in the revised manuscript's appendix.
We performed paired comparisons across the 90 fixed–moving HCP test pairs to quantify the observed performance differences. For each registration pair, we computed the difference between our method and the corresponding baseline and report the mean paired difference together with its 95% confidence interval.
mrregistermrregisterIn the paired analysis, our method achieved significantly higher bundle Dice than both baselines and significantly lower Hausdorff distance than DDMReg. Although
mrregisterhad a slightly lower mean Hausdorff distance, that difference was not statistically significant.We agree that the limitations discussion is currently narrow. In the revision, we will expand it to discuss the need to assess generalization to additional acquisition protocols and clinical populations beyond those considered in this study.