- Rating
- 4
- Clarity
- 4
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 2
Read review
Summary
FullTilt proposes an end-to-end framework that directly localizes 3D particles from raw 2D tilt-series, bypassing the conventional tomogram reconstruction step entirely. By combining epipolar-constrained row attention for multi-view feature fusion, a visual prompt encoder for open-set detection, and a lightweight synthetic data module, the framework achieves competitive zero-shot detection performance while reducing inference to under one second.
Strengths and weaknesses
Strengths
- This is a thorough and well-written manuscript with detailed descriptions of the architectural design choices and comprehensive experimental validation.
- The network is elegantly designed, supported by carefully structured ablation studies and sufficient experiments across diverse settings. The authors provide a new perspective that we can localize 3D particles from raw 2D tilt-series.
- The framework achieves substantial inference acceleration compared to existing methods, which is a practically significant contribution.
Weaknesses
- While the speed improvement is impressive, the detection performance results are not sufficiently convincing. Although FullTilt reports quantitative improvements on experimental datasets, the qualitative results tell a different story: TomoTwin appears to produce visually cleaner detections in most cases, while FullTilt tends to generate a notable number of false positives. More critically, FullTilt does not demonstrate a clear advantage over TomoTwin on simulation datasets. The current evidence is therefore insufficient to establish FullTilt's detection superiority beyond its speed benefit.
- As the authors themselves acknowledge, the method struggles with highly non-globular particles due to its simplified single-diameter bounding box formulation. This limitation is further compounded by the Auxiliary Geometric Primitives module, which fails to expose the model to the geometric diversity of real biological macromolecules. Given that non-spherical structures are the norm rather than the exception in structural biology, this represents a fundamental concern about the method's general applicability.
- Scale bars are missing from the figures. This is essential for biological imaging data, where spatial context is critical for interpretation, and should be added to all relevant visualizations.
Questions
While the authors acknowledge these limitations, I do not believe the manuscript is ready for acceptance unless the following major concerns are addressed:
- The single-diameter bounding box formulation should be modified, and the authors should demonstrate that FullTilt can handle structurally diverse particles, especially non-globular ones.
- The detection performance needs to be more consistently competitive. A fast but insufficiently accurate method is not compelling enough for a top-tier venue. I hope addressing comment 1 can also improve overall detection quality, such that FullTilt performs comparably to existing methods across all evaluated datasets, not only in select favorable cases.
Limitations
yes
Paper formatting concerns
no
Final justification
The rebuttal substantially alleviated my main concerns. In particular, the new experiments across proteins with a broad range of axis ratios provide convincing evidence that particle elongation, at least within the tested range, is not a major limiting factor for FullTilt. The clarification and additional precision/recall analysis also resolve my concern that the qualitative results necessarily indicate substantially more false positives than TomoTwin. Finally, the extended-G experiments considerably strengthen the simulation results.
I still have some reservations regarding the sensitivity to the synthetic training distribution, particularly because extending G leads to substantial performance changes, and TomoTwin remains significantly better on Sim-OOD AP@1r. I would like these results and limitations to be clearly incorporated into the revised manuscript. Nevertheless, given the additional evidence together with the substantial computational advantage of FullTilt, I no longer view my original concerns as sufficient grounds for rejection and have raised my score accordingly.
We thank the reviewer for the careful assessment. Below, we address the reviewer's concerns with the following clarifications and additional analyses:
On real-world datasets, FullTilt accelerates inference by orders of magnitude while matching or significantly exceeding TomoTwin’s detection performance, offering substantial practical value to the field.
[W2, Q1] Single-diameter representation and non-globular particles.
Our limitation statement (L269-270: suboptimal) referred to potentially reduced performance for highly non-globular particles, not an inability to detect them. A single diameter d imposes no explicit spherical shape model: it provides an isotropic scale prior that guides Deformable Attention’s sampling region. Particle recognition instead relies on class prototypes and cross-view features, neither of which explicitly constrains particle shape. Thus, d does not prevent the decoder from recognizing and centering an elongated particle.
We conduct a systematic analysis on 20 proteins (simulation data), spanning a wide range of shapes (axis ratios ∼1.1–2.9, defined as the ratio of the longest to the shortest PCA-derived principal-axis length of the density) and molecular weights (∼43–2,366 kDa) to test non-globular detection and identify factors associated with failure. When ranked by axis ratio (higher values indicate less globular shapes), the most elongated protein, 1OAO (2.94), achieves an [email protected] of 0.61, comparable to 0.65 for the highly globular 1E9R (1.15), as shown in Tables R1 and R2.
Table R1: In-distribution simulation. ▲/▽:significantly higher/lower; ns: not statistically distinguishable at the available sample size; *: p<0.05; **: p<0.01.
Table R2: Out-of-distribution simulation. Same legend as R1.
The failures are driven by weight, not shape: every near-zero case is below 100 kDa, and 3HHB (1.27) and 3GL1 (1.50) are near-globular yet still fail. If shape were limiting, these should be the easy cases. Accordingly, AP correlates with weight (Spearman ρ≈0.84/0.86, p<10⁻⁵) but not with axis ratio (ρ≈−0.16/−0.22, p≈0.50/0.36; Table R3).
Table R3. FullTilt AP vs. particle properties (Spearman).
We will clarify this and explore richer parameterizations, but the evidence does not indicate that single-d prevents detection of non-globular particles.
Role of 𝒢 and biological shape diversity.
𝒢 is not the sole source of shape diversity. FullTilt is trained on simulated tomograms of 119 protein structures; 𝒢 is interleaved to provide diverse spatial distributions and imaging artifacts. Its benefits are not limited to globular particles. Wilcoxon signed-rank tests (Tables R1/R2) show gains across the axis-ratio range, including elongated particles (1F1B, 2.22: 0.19→0.28; 1OAO, 2.94: 0.53→0.61), whereas performance declines for the most globular particle (2DF7, 1.12: 0.97→0.93). Thus, 𝒢 serves as an auxiliary regularizer for multi-view geometry and robustness, not a globular-specific augmentation.
[W1, Q2] Qualitative appearance and simulation performance.
1. Qualitative appearance.
The visualization layout may have invited an unintended comparison between two different representations. The FullTilt panels (Figs. A5, A11, A17, A23, A29) on the raw tilt-series project 3D detections through the full specimen depth onto a 2D tilt image, so particles at all depths overlap and the panels look denser. The TomoTwin panels (Figs. A9, A15, A21, A27, A33) show a single tomogram Z-slice, where only detections within the displayed depth are visible. The visual-density difference between these two panel types therefore cannot be read as a difference in false-positive rate.
For a like-for-like comparison, FullTilt is also visualized on the same tomogram Z-slices as TomoTwin (Figs. A7, A13, A19, A25, A31). Each method uses the confidence threshold maximizing its F1 over the full evaluation set. Table R4 reports the precision, recall, and F1 for the detections shown in these figures. At these F1-optimal points, FullTilt trades some precision for higher recall; its lower precision should not be considered in isolation as evidence of generally worse false-positive behavior. mAP, reported throughout, evaluates the full precision–recall curve rather than a single operating point.
Table R4. Detailed metric values for the visualized instances. Sim: simulation; ID: in-distribution; OOD: out-of-distribution.
2. Simulation performance.
We agree the original FullTilt is not consistently better than TomoTwin on simulation. To test whether performance can be improved without modifying the architecture, we broadened the training distribution using an extended 𝒢 with additional noise patterns (white, Poisson, and speckle noise) and primitives (cube and shell). The results are shown in Table R5.
Table R5. FullTilt with extended 𝒢 (same architecture and optimization hyperparameters). Wilcoxon signed-rank test (10 trials). Same legend as R1.
With the same architecture, FullTilt (extended 𝒢) significantly outperforms TomoTwin in 6 of 10 dataset–metric comparisons, shows no significant difference in 3 (with higher point estimates in all three), and performs significantly worse in only 1. TomoTwin remains ahead only on Sim-OOD mAP@1r, whereas FullTilt is significantly better on the stricter Sim-OOD [email protected] (0.545 vs. 0.531). These results indicate that training-distribution coverage contributes to the original simulation gap and that broadening this distribution can improve simulation performance while retaining competitive real-world performance, without modifying the architecture or single-d formulation. Fully closing this gap is part of the broader training-diversity exploration we note as future work.
[W3] Scale bars.
Thank you for catching this. We will add scale bars to all relevant figures in the revision.