- Rating
- 6
- Clarity
- 4
- Confidence
- 3
- Originality
- 3
- Quality
- 4
- Significance
- 3
Read review
Summary
The paper introduces the “polar transformer,” a permutation-invariant architecture for sets of cryo-EM projection images that is equivariant to independent in-plane rotations of each image.
The method relies on a carefully constructed polar representation based on Gaussian RBF interpolation, polar CNNs using angular convolutions (equivariant to angular translations), and a novel angular attention mechanism that computes attention over all relative angular shifts via FFTs.
On large-scale simulated cryo-EM data, the polar transformer significantly improves denoising performance over single-image baselines and RELION class averaging, and the denoised images lead to improved downstream ab initio 3D reconstructions
Strengths and weaknesses
Well-motivated SO(2)^K–equivariant design for cryo-EM image sets. The central design choice of treating each image as a token and using an attention mechanism that is equivariant to independent rotations of each token is well-aligned with cryo-EM physics, where each particle image has an unknown in-plane rotation. The formulation in Section 3.3, especially Equations (3)–(6), clearly connects angular shifts in the polar domain with SO(2)^K equivariance in the Cartesian domain.
Technically careful polar representation with stability guarantees. The use of Gaussian RBFs on a Gauss–Jacobi quadrature grid is more sophisticated than standard nearest-neighbor/linear polar interpolation. Proposition 1 rigorously shows that ( P^T P ) approximates a convolution with a Gaussian kernel (\phi), with explicit error terms (Equation (10)). Appendix B further argues approximate isometry and bounded operator norm. The comparison against standard interpolation in Appendix B nicely demonstrates the improved stability of the proposed mapping in practice.
Clean architectural story from polar CNNs to polar transformers. Angular convolutions (Equation (2)) are a natural and efficient way to achieve rotation equivariance, avoiding the complexity of Clebsch–Gordan or Fourier-space equivariant CNNs while still aligning with group-theoretic formulations (Kondor & Trivedi [29]). Building polar CNNs from these layers and then inserting multi-head angular attention yields a conceptually coherent pipeline, summarized well in Figure 2.
Angular attention mechanism is conceptually strong and ablated. The angular attention in Equation (3) and (4) is a meaningful extension of standard dot-product attention: it explicitly searches over relative angular shifts and uses FFTs for efficiency. The ablation in Table 2 shows that replacing angular attention with standard attention (“Std. attention”) hurts performance (Rel. MSE 0.058 vs 0.050 for standard polar transformer under smaller training regime), and reducing the number of heads or blocks also degrades performance. This supports the claim that the SO(2)-aware attention is the key ingredient.
Questions
Are image sets for training always composed of projections from the same molecule, or are they mixed across molecules? In Table 3, when varying the number of images in a set at test time, are the images always from the same underlying 3D structure? Understanding how homogeneous these sets are is critical for extrapolating to mixed or heterogeneous experimental datasets.
Can you provide either (i) an explicit proof sketch of Equation (5) for the angular attention under the continuous, idealized polar transform, or (ii) an empirical measure of equivariance error (e.g., (| f(R_\gamma x) - R_\gamma f(x) | / |x|) over random rotations) to quantify how well the architecture preserves equivariance in practice? This would make the claims around SO(2)^K-equivariance more precise.
You mention in the Introduction that training on real cryo-EM data would require a strategy like Noise2Noise and that the model is “capable of this.” Can you outline a concrete training setup? For example, how would you handle CTF variation, particle heterogeneity, and unknown orientations in a purely self-supervised setting? Any preliminary experiments on real micrographs would substantially strengthen the paper.
Limitations
Evaluation solely on simulated data with an unrealistically strong supervision signal. All results are on synthetic projections obtained from PDB structures with known viewing directions, CTF, and shifts
Weak comparison to modern cryo-EM denoisers and transformer-based pipelines. The only domain-specific baseline is RELION 2D classification/class averaging, which is a generically applicable but relatively old denoising strategy.
Complexity and scalability of angular attention not addressed experimentally. The angular attention mechanism has computational complexity (\mathcal{O}(K^2 L^2 \log L)) (Section 3.3). While Table 1 and Table 3 report throughput (images/s), there is no systematic analysis of scalability as K grows beyond 1000, nor discussion of typical K in realistic workflows (millions of particles per dataset). Given the quadratic dependence on K, the approach may be impractical for large datasets unless heavily batched/subsampled; this tension is not analyzed.
3D reconstruction evaluation is narrow and uses a somewhat outdated ab initio baseline. The reconstruction experiments (Section 4.5) use SyncVoting (ASPIRE) common-lines ab initio with 1000 projections per molecule. This is an interpretable but older approach; many modern pipelines (cryoSPARC, CryoDRGN variants, amortized pose estimators) use more advanced probabilistic models and non-linear refinement.
Paper formatting concerns
NA
We have run new experiments for each of the three questions. Unless noted, every relative MSE below is on the 100-molecule held-out test set of Section 4.3, at the stated set size.
Q1 (set composition). The sets in the paper are homogeneous: all K images are projections of the same molecule from different viewing directions. This matches the stage immediately after 2D classification and is also how the experiments in Table 3 were constructed.
We repeated the experiment using heterogeneous sets while keeping everything else fixed (projections, CTF, shifts, and noise). Only the grouping changes. Each set contains J distinct molecules with K=384.
The third row reports the fraction of non-self attention assigned to images of the query's own molecule. Even with eight molecules per set, attention is still concentrated on the correct structure (26.5% versus a 12.3% chance baseline, a 2.16× enrichment), although the separation is incomplete. Performance degrades smoothly as more structures are mixed, reaching a 51% increase in relative MSE at J=8.
Q2 (equivariance). This experiment changed the paper. It showed that the transformer in the submitted version is not equivariant, identified the source of the violation, and led us to replace it with an equivariant variant for the camera-ready paper.
The Cartesian quantity you requested, ∥f(Rγx)−Rγf(x)∥, is reported relative to each model's own rotation round-trip error. This normalization is necessary because interpolation introduces a model-dependent floor.
Our polar CNN is essentially at its interpolation limit. DnCNN, despite being trained on uniformly random in-plane rotations, remains far from equivariant.
This metric is not informative for the polar transformer because most of its output energy lies outside the frequency band occupied by the clean images (74% versus 0.6%), which substantially inflates the interpolation floor. We therefore evaluated equivariance directly in the polar domain, where rotations are exact angular shifts. Under this metric the trained polar transformer is not equivariant: its relative error ranges from 0.61 to 1.17, whereas the same architecture at initialization achieves 4×10−7.
Inspection of the trained model pointed to the angular layer normalization. Our implementation used the default elementwise affine over (channel, radial, angular), allowing the learned scale and bias to vary with angle. Almost all of the variance in these affine parameters is angular (92.8%), and 22 of the 24 tensors are dominated by the first angular harmonic.
Constraining the affine to be constant along the angular dimension restores equivariance. After retraining, the error drops by roughly four orders of magnitude to the low 10−5 range, while relative MSE increases modestly from 0.0576 to 0.0594 at K=100. The constrained model also has 0.88M fewer parameters.
This is now the model used in the paper. Tables 1–3 and Figures 4, 5, and 7 are being regenerated using the constrained architecture, so the final reported results will correspond to a model that is equivariant by construction.
Retraining is still in progress, so we do not want to overstate the final accuracy gap. It was 3.8% at an earlier checkpoint and has already fallen to 3.0%, and we expect further fine-tuning to narrow it further before the camera-ready version.
The remaining equivariance error is also not purely numerical. Recomputing in double precision leaves it essentially unchanged, whereas our polar CNN control improves from roughly 2×10−7 to 4×10−16. We therefore believe a second, much smaller source of equivariance error remains, and are currently isolating it.
While re-deriving the proof we also found a typo in Eq. (4), discussed below.
Q3 (real data / Noise2Noise). We propose a pair-free objective. Each particle is estimated from the opposite half of its own set and compared against its own observation after applying that particle's 2D CTF: ∥CTF⋅f(y)−yi∥2.
The CTF term is essential. Omitting it encourages the network to reproduce the CTF-corrupted image rather than learning the underlying deconvolution. Unknown in-plane orientations require no additional treatment because they are precisely the nuisance removed by SO(2)K-equivariance. Heterogeneity is handled through the set mechanism evaluated above.
We also considered classical Noise2Noise pair construction. Pairs could be obtained from independent halves of the same exposure or from nearest-neighbor particles, but in our data nearest-neighbor pairs are no more likely to share a viewing direction than a rotation-aligned random particle from the same micrographs (low-band FRC 0.175 versus 0.188 for the null).
We additionally tested whether the architecture uses meaningful set context on experimental data without any real-data training. We evaluated weights trained only on synthetic projections, using held-out experimental EMPIAR particles in a zero-shot setting. Each estimate was constructed from the opposite half of its own set, so no pairing assumption enters.
Across 14,592 particles, replacing a particle's own set with a set from a different protein reduces mid-band (0.15–0.40 Nyquist) agreement by 0.029 (95% CI [0.016, 0.042]), with the effect present in 18 of the 19 structures. For comparison, we repeated the experiment using RELION 2D classification on the same halves. RELION's corresponding context effect is indistinguishable from zero (-0.003), giving a paired difference of 0.032 (95% CI [0.008, 0.056]).
We report the difference rather than the raw agreement because, at 53–29 Å resolution, essentially any particle image shares a coarse overall shape with any other, producing a baseline correlation of roughly 0.10. The differential isolates the contribution of the set context itself.
This evaluation requires a residual-free network, so it uses a reduced-depth variant of the architecture, although the equivariant angular-attention core is unchanged. We also do not make any reconstruction-level claim on experimental data, since our current 3D evaluation does not yet support one.
On scalability. Here K is the context window rather than the dataset size. Evaluating the same model up to K=8000 changes the relative MSE only from 0.0473 to 0.0453, with performance essentially flat beyond K≈3000.
A dataset containing 106 particles is therefore processed as roughly 103 independent sets. The overall computation scales linearly with dataset size, while the K2 attention cost remains a fixed per-set constant. Query chunking removes the memory bottleneck exactly, allowing K=8000 in 36 GiB. The full sweep and measured memory model are included in our response to Reviewer uN8r.
On baselines. Both baseline families were already included in the submission, although we did not make this sufficiently clear. The U-Net baseline is the Topaz-Denoise architecture [5], and the transformer baseline is SWIN-IR; both appear in Table 1. Our Topaz model is trained on our synthetic data rather than initialized from the published Topaz-Denoise weights, so the comparison is like-for-like. We will make the provenance of every baseline explicit in the camera-ready version.
For ab initio reconstruction we chose a common-lines method because it operates directly on denoised images without estimated poses, allowing the comparison to isolate denoising quality. Methods such as cryoSPARC and cryoDRGN introduce additional priors and iterative refinement. We agree that this should also be measured empirically, and we will therefore include a cryoSPARC ab initio comparison in the camera-ready.
Correction to Eq. (4). While re-deriving the proof we found a typo. Inside the double sum, Eq. (4) prints the value image as Sℓzk⊛hvalue, but this should be zk′. As printed, the sum over k′ contains no k′-dependent term and the expression is not equivariant. The implementation uses the correct form, and the camera-ready version has been corrected.
Proof sketch for Eq. (5). Let Sℓ denote angular shift. Since angular convolution commutes with shifts, substituting zk↦Sℓkzk into Eq. (3) simply reindexes the attention scores:
\= \alpha^\{�2�\}_\{k\\\,k\'\}�3�\,$$ where $m=\ell+\ell_{k'}-\ell_k$. Because the softmax is taken jointly over $(k',\ell)$, this reindexing leaves it unchanged. Applying the same substitution to the corrected Eq. (4) yields $$f�4�\=S_\{\boldsymbol\ell\}f�5�\,$$ proving Eq. (5). Equation (6) then follows from $PR_\gamma\approx S_\ell P$ (Section 3.2): exact on the angular grid, with the remaining discrepancy arising only from interpolation in the RBF-polar mapping.