- Rating
- 3
- Clarity
- 2
- Confidence
- 4
- Originality
- 1
- Quality
- 2
- Significance
- 2
Read review
Summary
This paper addresses the challenge of Extremely Sparse-View Computed Tomography (xSV-CT) under a highly restrictive "train-sparse / infer-sparse" paradigm. In specific clinical and industrial environments (e.g., intra-operative C-arm navigation, dynamic cardiac imaging, or scanning highly radiation-sensitive biological specimens), fully-sampled 3D CT scans are unavailable for both training data curation and inference testing. The authors propose a framework consisting of: (1) A 2D denoising diffusion probabilistic model (DDPM) trained on only a single 2D projection per training sample, augmented with sinusoidal pose encoding and multi-scale cross-attention injection to learn angle-conditioned projection statistics; and (2) A testing-time guidance loop that directs reverse diffusion sampling using two complementary constraints: a geometric coherency loss and a physics-informed consistency loss. Evaluations on two public datasets (CT-RATE and SinoCT) show state-of-the-art performance in synthesizing novel views and reconstructing highly accurate 3D volumes under 1-, 4-, and 8-view contexts. There are many published works on the topic (the authors, unfortunately, simply ignored many of previous publications on the topic), the work does not add much either theoretically or practically.
Strengths and weaknesses
Integrating projection physics (Radon transform) into the diffusion sampling step merges statistical learning with established physical principles. The choice of using an adaptive Adam optimizer for step-wise corrector updates may add numerical stability. Unlike pure learning-based regression networks that can hallucinate non-existent anatomies, the inclusion of physics constraints may allow this framework to preserve global structural integrity and degrade into mild blurring during out-of-distribution (OOD) testing.
The reconstruction pipeline requires optimization loops through differentiable projection/reprojection operators at every denoising timestep. The inference time is too long, severely restricting its viability for real-time intraoperative applications. The novelty of the study is at most moderate, as there have been numerous studies on view generation and on extremely sparse CT reconstruction. The authors frame their "train-sparse / infer-sparse" paradigm and projection-domain diffusion approach as almost entirely unprecedented, omitting several crucial foundational and concurrent developments.
The work's core premise relies on synthesizing high-fidelity volumes from extremely limited 2D projections. However, the authors fail to credit the pioneering work by others, which originally established the paradigm of deep learning-based CT reconstruction from a single or a few projection views.
Questions
The finite-order Range-Condition surrogate seems to be inherently restricted to parallel-beam or rebinned fan-beam configurations. While rebinning works well mathematically for standard geometries, it adds algorithmic complexity and does not natively support true cone-beam setups or non-coplanar geometries without translating to alternative metrics.
Although the problem formulation intends to skip dense 3D volume supervision, the clinical datasets utilized to evaluate the methodology were still curated via simulated projections extracted from public dense scans to capture metric references. Prospective evaluation on true experimental, natively sparse-only data remains unaddressed.
Limitations
yes
Paper formatting concerns
non concerns
Final justification
The responses regarding the train-sparse scope distinction, geometry coverage, and efficiency context addressed my main concerns. I am increasing my score to 3.
We thank the reviewer for recognizing that integrating Radon physics into the sampling step combines statistical learning with established physical principles, and that the physics constraints help preserve global structure rather than hallucinate anatomy. We address the concerns below, and would welcome any specific reference the reviewer would like us to add.
W1: Inference time cost:
We agree that inference time is an important practical consideration. At our default setting (N=180), reconstruction from 4 sparse views takes approximately 46 minutes on CT-RATE, while increasing the number of input views has little effect (47 min for 8 views and 50 min for 32 views). Among methods needing only per-dataset retraining this is an order of magnitude faster than the closest comparisons (e.g., DiffusionMBIR exceeds 10h per case on NVIDIA RTX A6000 GPUs as our setting, and TPDM (ICCV'23) reports exceeding20h at 256³ in their paper with NVIDIA RTX 3090 GPUs).
Importantly, the current implementation is readily parallelizable. We currently synthesize 48 projections at a time on a single GPU, and distributing this computation across multiple GPUs can further reduce the wall-clock time without changing the algorithm or reconstruction quality. Experimenting with four GPUs that parallelize the synthesis of full N=180 projections can bring runtime to roughly 35% at unchanged performance.
In addition, the runtime can be adjusted by choosing the number of synthesized projections N. As discussed in the manuscript (L519), the runtime increases approximately linearly with N (t≈10+0.2N min). Figure 5 reports the corresponding quality-runtime trade-off across different values of N, allowing users to balance reconstruction quality against computational cost.
Finally, real-time intra-operative imaging is one motivating application, but latency reduction is not the primary target of this work. Our focus is on acquisition-limited scenarios, including low-dose CT, industrial inspection, and retrospective dynamic CT, where a limited number of available projections is often the key challenge rather than reconstruction latency. To better clarify the intended scope and practical trade-offs, we will move the runtime discussion from the appendix to the main paper and clarify these implementation details in the revised manuscript.
W2: Credit to prior work
We do not claim that novel-view generation or xSV-CT are themselves new; both are cited extensively in the Related Works. Our claim is narrower: to the best of our knowledge, this is the first work among existing publications to explicitly study a train-sparse / infer-sparse setting for sparse-view CT, in which no reconstructed slice or volume is used as supervision at any stage and is beneficial to scenes where a dataset of dense-view volumetric reconstructions is difficult to obtain beforehand.
Following the Area Chair’s suggestion, we will expand the discussion of prior sparse-view CT literature in the revised manuscript to better position our work with respect to existing methods. As the review does not identify specific missing prior works or concrete baselines, we will provide discussion of the line we believe is intended, which we refer to as X-ray to CT generation from one or a few views at predefined poses: e.g., “Patient-specific reconstruction…” (Nature BME’19), X2CT-GAN (CVPR’19), MedM2G (CVPR’24). We will credit these explicitly as establishing the fact that networks can infer volumetric structure from very few views. However, every one of them still forms its training pairs from reconstructed 3D slices or volumes, which our setting removes, and scaling them to incorporate different scanner poses or more views is not trivial. The same training requirement holds for other prior volume-based methods we discussed, such as DIF-Gaussian (MICCAI’24), TPDM, X-LRM (3DV’26), and the volume-based baselines we compare against. We will add these references in revision, and would be willing to discuss any other specific work the reviewer has in mind, or run any baseline they consider necessary.
Q1: Geometry coverage
The finite-order Range-Condition surrogate is indeed used only for the physics-informed consistency loss, as stated in the Limitations (L292–294), and does not restrict the framework itself. The geometric coherency loss is geometry-agnostic and applies unchanged to cone-beam and non-coplanar geometries.
Moreover, the rebinning approximation can be removed by replacing the finite-order Range-Condition surrogate with Grangeat’s condition for cone-beam geometry. In this case, full 3D reconstruction additionally requires synthesized projections to satisfy Tuy’s sufficiency condition through non-planar acquisition orbits. We will clarify this discussion and present it as a promising future direction.
Q2: Measured versus simulated data in our evaluation
This concern applies only partially to our evaluation. Among the two datasets used in the paper, only CT-RATE uses simulated projections. For SinoCT, we use the real fan-beam measurements provided by the dataset, without any forward projection during training. Therefore, the SinoCT experiments are already performed entirely in the measurement domain.
We agree that prospective validation on radiation-sensitive specimens without dense reference volumes is an important future direction. As stated in L292, we plan to evaluate our framework on such truly sparse-only data in future work.