- Rating
- 3
- Clarity
- 2
- Confidence
- 4
- Originality
- 2
- Quality
- 2
- Significance
- 2
Read review
Summary
This paper proposes Geometry-Gated TD-DIP for dynamic MRI reconstruction under a “weak diffusion” setting. The core idea is to use a pretrained, potentially mismatched 2D diffusion model not as a dominant generative prior, but as a local geometric reference. At each reverse step, the method computes a Tweedie anchor from the diffusion model, fits a scan-specific TD-DIP reconstruction through a proximal objective, decomposes the TD-DIP correction into diffusion-tangent and orthogonal components, and adaptively gates the orthogonal innovation before the sampler update. The paper reports strong empirical results on dynamic cardiac MRI, including high acceleration, cross-vendor generalization, and prior-mismatch experiments.
Strengths and weaknesses
While the empirical performance is promising, I found the conceptual positioning and theoretical justification insufficiently convincing. The method entangles several factors: test-time optimization, TD-DIP temporal modeling, a frozen 2D diffusion prior, tangent-normal decomposition, and adaptive gating. As a result, it is difficult to determine whether the gains come from the proposed geometric mechanism or from the broader benefit of combining a dynamic scan-adaptive INR/DIP with a weak spatial diffusion prior. The relationship to prior work on test-time diffusion-prior adaptation, especially DDIP[1] and SCD[2], should also be made much clearer.
Strengths
- The paper addresses an important and practical problem: dynamic MRI reconstruction under aggressive undersampling and diffusion-prior mismatch.
- The proposed method is intuitively reasonable. Using diffusion as a weak stabilizing anchor while letting TD-DIP recover scan-specific dynamics is a plausible design.
- The empirical results are strong across multiple undersampling settings
Weaknesses
The paper is generally hard to read, with several components not fully justified along the way.
- L87: DPS places a dirac approx with . One that places a Gaussian is GDM [3].
- Sec 2.5. needs more explanation. What do the authors mean by "manifold-constraint view"?
The theoretical analysis is weak. Several results are essentially consequences of definitions rather than meaningful guarantees.
- The assumptions behind the theory are strong and not well justified. For instance, Assumption 3.2 requires restricted data curvature on the TD-DIP manifold. In highly undersampled dynamic MRI, this is precisely the kind of identifiability condition that is hard to expect without evidence.
- Assumption 3.4 is also questionable. The theory assumes the denoiser Jacobian is close to an oracle tangent map, non-expansive, and approximately idempotent. This is a very strong assumption for a pretrained, intentionally mismatched diffusion model.
- The positioning relative to DDIP is insufficient. DDIP also addresses OOD diffusion-prior adaptation for inverse problems using a proximal test-time objective, but adapts the diffusion model parameters rather than a separate DIP/INR network. The present paper is algorithmically different, but the high-level motivation is closely related. The novelty should be framed more carefully as frozen-diffusion geometry plus TD-DIP adaptation, rather than as an entirely new weak-diffusion paradigm.
- Important ablations are missing. In particular, the paper should disentangle 2D vs dynamic diffusion priors, frozen diffusion vs diffusion-parameter adaptation, TD-DIP architecture effects, and the actual contribution of the tangent-normal gate under matched compute.
Minor
- L88: Is the anchor strength? I'm confused since this is inverse.
References
[1] Chung, Hyungjin, and Jong Chul Ye. "Deep diffusion image prior for efficient ood adaptation in 3d inverse problems." ECCV 2024.
[2] Barbano, Riccardo, et al. "Steerable conditional diffusion for out-of-distribution adaptation in medical image reconstruction." IEEE Transactions on Medical Imaging 44.5 (2025): 2093-2104.
[3] Song, Jiaming, et al. "Pseudoinverse-Guided Diffusion Models for Inverse Problems", ICLR 2023
Questions
- Why is a 2D diffusion prior the appropriate object for defining tangent geometry in a dynamic 2D+t reconstruction problem? Would the method still provide gains if the diffusion prior were a dynamic 2D+t diffusion model?
- How much of the improvement comes from the proposed tangent-normal gating, versus simply combining a frozen 2D spatial diffusion prior with a strong dynamic TD-DIP model?
- Can the authors compare against or discuss DDIP more directly?
- Can the authors empirically validate Assumption 3.2 by reporting singular values or conditioning?
- Can the authors empirically validate Assumption 3.4 by measuring whether the denoiser Jacobian is actually near-idempotent, non-expansive, or projection-like under matched and mismatched priors?
Limitations
yes
Paper formatting concerns
N/A
Final justification
I appreciate the authors’ substantial effort in the rebuttal, including the stronger baselines, radiologist evaluation, ablations, and more careful theoretical framing. However, my main concern remains unresolved: the revised theory is considerably weaker than the original geometric interpretation, providing only conditional local bounds and an essentially algebraic characterization of the gate, without explaining when the residual correction is actually beneficial for reconstruction. The new experiments strengthen the empirical case, but I view them as supporting a useful dynamic-MRI-specific method rather than establishing the broader methodological or theoretical contribution claimed by the paper. Overall, the rebuttal improves the work, but not enough to outweigh my concerns about significance and the informativeness of the theoretical contribution, so I maintain my score of 3.
We thank the reviewer for the detailed theoretical critique.
On W1 Incorrect statement:
The local Gaussian approximation should not be attributed to standard DPS as stated in the original manuscript. We will revise this statement and distinguish between the Dirac approximation used in DPS and the Gaussian local modeling in the relevant guided diffusion formula.
On W2 Manifold-constraint view:
In our paper, this term refers to the implicit constraint introduced by the scan-specific TD-DIP parameterization, rather than an explicitly known or globally defined data manifold. Specifically, TD-DIP defines a feasible image set Mk={xϕ∣ϕ∈Vk} and the Stage-B optimization searches within this set instead of the full image space. Separately, the diffusion Jacobian Jθ,k=∇xDθ,k(xk) is used to describe the local sensitivity of the denoiser and guide the correction decomposition.
We agree that the original wording may have caused ambiguity, and we will revise the manuscript to distinguish TD-DIP as an implicit image-set constraint and the diffusion Jacobian as a local sensitivity operator, rather than implying a rigorously defined data manifold or an exact tangent projector.
On W3 & Q4 Assumption 3.2:
Due to space constraints, please refer to the section "On Q1 Assumption 3.2" in the rebuttal addressing reviewer mdsH.
On W4 & Q5 Assumption 3.4:
We agree that a learned, intentionally mismatched denoiser Jacobian should not be assumed to be an exact orthogonal tangent projector. We therefore revise the decomposition from dk∥=Jθ,kdk,dk⊥=(I−Jθ,k)dk
to
dksens=Jθ,kdk,dkres=(I−Jθ,k)dk,
which we call the prior-sensitive and prior-residual components. The algorithm itself is unchanged.
Define
Gθ,k(λ)=λI+(1−λ)Jθ,k.
For any reference sensitivity operator Jr,k ,
Gθ,k(λ)−Gr,k(λ)=(1−λ)(Jθ,k−Jr,k).
Therefore,
\||G_{\theta,k}(\lambda)d - G_{r,k}(\lambda)d\||_2 \leq (1-\lambda) \||J_{\theta,k}-J_{r,k}\||_2 \||d\||_2. \tag{1}
Equation (1) requires neither idempotence, symmetry, non-expansiveness, nor an orthogonal-projection interpretation. Its meaning is direct: a larger λ makes the update closer to the complete TD-DIP correction and reduces sensitivity to disagreement between the weak diffusion operator and the reference operator.
Similarly,
x0,k−xkDIP=−(1−λk)(I−Jθ,k)dk,
so
\||\widetilde x_{0,k} - x_k^{\mathrm{DIP}}\||_2 = (1-\lambda_k) \||(I-J_{\theta,k})d_k\||_2. \tag{2}
Equation (2) quantifies the gate-induced deviation from the full TD-DIP update. It does not claim that this deviation necessarily lowers the reconstruction error.
We evaluated the three diffusion priors used in the paper at matched reconstruction states using JVPs and VJPs. The empirical symmetry residual
∥∣v∥∣2∥∣(J−JH)v∥∣2
ranged from 0.008 to 0.067. Other projection-related quantities, including the operator gain and idempotence residual, varied across prior types and reverse stages.
We also measured discrepancies between the matched-prior operator and the two weaker operators. In the middle and late reverse stages, the matched-to-OOD discrepancy was larger than the matched-to-generic discrepancy, consistent with the ordering of prior mismatch.
These observations support the revised formulation: the Jacobian is informative as a local sensitivity operator, but its projector-like properties should be treated as diagnostics rather than necessary assumptions.
We will therefore remove non-expansiveness and near-idempotence from the assumptions required by the main mismatch result.
On W5 & Q3 DDIP:
We agree that both DDIP and the present paper focus on the test-time adaptation of diffusion priors for OOD inverse problems; thus, they are closely related in terms of high-level motivation. The original manuscript did not sufficiently highlight this relationship.
DDIP primarily targets static 2D and 3D inverse problems. In contrast, this paper specifically addresses dynamic MRI, employing TD-DIP to construct a shared temporal implicit manifold within a single scan, thereby recovering inter-frame dynamics and temporal consistency. And DDIP differs from the method in this paper regarding the role of the diffusion model.
To facilitate a direct comparison, we supplemented our study with DDIP experiments conducted on the full cardiac cine test set (118 cases). All methods employed the same experimental settings and fixed VISTA 12×/24× masks as described in the paper. For DDIP, we utilized the publicly available fastMRI checkpoint, official hyperparameters, and a fixed random seed, without performing dataset-specific hyperparameter tuning.
As the public DDIP implementation was not specifically designed for dynamic MRI, we evaluated two plausible implementations: DDIP-2D, which applies the official 2D solver frame-by-frame; and D3IP-Time, which maps the temporal dimension to the third dimension of D3IP and shares LoRA parameters. The results are presented in Table 1.
Table 1. Comparison of different DDIP implementations and the method proposed in this paper.
We attribute this discrepancy primarily to the approaches employed for dynamic sequence modeling. DDIP-2D processes each time frame independently, failing to leverage temporal information across adjacent frames; conversely, D3IP was originally designed for 3D volumetric data, and interpreting its third dimension merely as time allows only for parameter sharing without explicitly modeling cardiac motion. The TD-DIP method proposed in this paper performs scan-specific fitting across the entire spatiotemporal sequence. This design reduces reliance on the quality of the diffusion prior fit in situations where the static prior and dynamic data do not perfectly align.
These results do not imply that DDIP is ineffective for the static inverse problems for which it was originally designed; rather, they indicate certain limitations in dynamic scenarios. We will include this comprehensive comparison in the revised manuscript. In addition, we will briefly discuss methods such as SCD in the "Related Work" section.
On W6 & Q2 Ablation experiment:
We conducted additional, more comprehensive ablation experiments. The newly added experimental setup eliminates vector decomposition and gating mechanisms, relying entirely on TD-DIP to guide the diffusion-based reconstruction. The results are shown in Table 2.
Table 2. Ablation study on the effectiveness of key components using VISTA mask at 12× acceleration.
The results demonstrate that each component of the proposed method contributes to the reconstruction performance.
On Q1: 2D + t Diffusion model
The apparent dimensional mismatch results from an overly compressed description in the submitted paper. We do not claim that the 2D denoiser Jacobian represents the complete tangent geometry of the dynamic (2D+t) image manifold.
Let X=(x1,…,xT) denote a dynamic sequence. The 2D diffusion model provides a frame-wise spatial sensitivity operator:
(D_{\theta}(x_1),\ldots,D_{\theta}(x_T)),$$ whose sequence-level Jacobian is approximately block diagonal, $$J_{\theta}^{\mathrm{seq}} \operatorname{diag}(J_{\theta,1},\ldots,J_{\theta,T}).$$ This operator only describes spatial prior sensitivity. Temporal coupling is provided by the shared TD-DIP parameters and the temporal latent encoding, which generate the entire sequence jointly. We address scenarios where task-specific dynamic (2D+t) diffusion priors are unavailable or come with high training costs. The 2D diffusion model is therefore used as a weak spatial reference, while TD-DIP supplies scan-specific temporal structure and measurement consistency.