- Rating
- 4
- Clarity
- 3
- Confidence
- 3
- Originality
- 2
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper proposes MOSAIC, a two-phased approach for multi-modal molecular generation operating on spectral and structural signals simultaneously. The flow model (second phase), uses a rectified flow formulation and operates in a latent space. This latent space is the result of a first phase of training, which is based primarily on a masked reconstruction training objective in addition to other training tricks. This phase additionally fine-tunes the structural portion of the latent representations obtained from a pre-trained UAE-3D model. This is intended to enable equivariance in the latent space. The flow matching phase randomly samples target and conditional modalities in order for the model to learn any-to-any generation. The authors show that this multi-modality leads to significantly improved performance on QM9S.
Strengths and weaknesses
Strengths
- This works demonstrably shows that multimodal, any-to-any generation is highly beneficial for the conditional generation models considered in this work.
- The method has strong empirical performance relative to existing work on the QM9S benchmark for spectra-to-structure generation. The paper appears to be the first to propose this conditional flow matching approach to the problem of joint structure and spectra generation.
- The paper is well written and clearly establishes the connection between the central motivation and contributions of the work.
Weaknesses
- Methodologically, this work is a fairly straightforward application of rectified flows using multiple input/output signals.
- Casting the flow matching vs diffusion formulation aside, the main differences with DiffSpectra appear to be related to the pretraining/encoder training procedure, which also relies heavily on the pre-trained UAE-3D model. This somewhat entangles the contributions from prior work with the current work. There are also many training tricks and architectural components which further entangles the contributions, but nonetheless the end result appears to work quite well.
- The model is tightly coupled to a fairly limited experimental setting (spectral-to-structure generation), which inherently limits the benchmark evaluation to QM9S, which is ultimately a synthetic dataset. This makes it somewhat challenging to assess real-world impact of the method.
- This is somewhat of a personal opinion, as I understand that scaling studies are popular in the current LLM-driven research environment, but I do not find the scaling portion of the experiments particularly impactful. They can be interpreted as “increasing model capacity leads to a better fit of the data”, which is the standard expectation in ML. This is compounded by the fact that QM9/QM9S have very similar train/test distributions, so they end up rewarding overfitting on the training distribution. It is also expected that additional input modalities would delay overfitting (panel (d) in Figure 4.
Overall, this multimodal generation task appears to be relatively underexplored, which the authors have exploited to make a meaningful empirical contribution to the field. The experiments are overall well designed, including ablation studies to justify certain training components, and I believe the strength of the improvement and clarity of the work outweighs the novelty concerns. However, I should note that I think this submission would have been better suited to ‘Use-inspired’, as the evaluation guidelines would be more favourable to this weighting.
Questions
- Have you compared the effect of the independent timestep sampling across modalities with matching timestep sampling across modalities, when training the flow model? Could you justify this choice? Given that the inference time-setup always has matching timesteps, it seems slightly counterintuitive that training would not do the same. It seems this could cause some additional gradient instability during training with sample modalities very far apart in the noising trajectory.
Limitations
I think the current limitations statement (appendix A), could be expanded to more clearly state what is hinted at (i.e. QM9 results may not represent real-world impact), which dilutes the conclusions that can be obtained from the results. Discussion of computational cost would also be valuable. While inference cost may be reduced relative to diffusion due to linear integration paths, training costs in two phases may be heavier, and sampling-based inference is still non-negligible.
Paper formatting concerns
No formatting concerns.
Final justification
Following the rebuttal, I believe the initial assessment was correct. While the methodological novelty and the scope of available benchmarks is limited, the paper is clear and underlines the value of multimodal flow matching in this application area.
Thank you for the detailed and thoughtful review.
W1/W2. Methodological novelty and contribution attribution
We thank the reviewer for the comment.
We do not use a pretrained UAE-3D checkpoint that has seen data outside of train set of QM9S. We reuse UAE-3D and train it from scratch on the same QM9S split. Every MOSAIC model and ablation uses the UAE-3D checkpoint trained solely on QM9S. As such, the weights from the entire MOSAIC can be derived from QM9S only, and does not require a pretrained model trained on data outside of QM9S.
The effect of any-to-any masking is isolated directly. Any-to-any training improves (over struct-only) Acc@1 by 1.95, 7.30, and 5.65 percentage points at S, M, and L model sizes. We therefore attribute some of the gains to any-to-any masking. Fine-tuned encoder configurations also score substantially higher than frozen configurations in the submitted table.
We thank the reviewer for acknowledging that MOSAIC's performance advantage over specialist baseline models.
W3. Experimental scope and real-world impact
We acknowledge QM9S does not establish real-world experimental generalization. Indeed, there is a sim-to-real gap: Trained only on QM9S (simulated molecules/spectra), MOSAIC generates IR spectra from candidate structures and retrieves among 139 experimental NIST gas-phase spectra. It reaches R@1/R@5/R@10 of 10.1%/28.1%/40.3%. However, these results from MOSAIC still outperform 6.5%/20.1%/33.1% for DetaNet (structure-to-spectrum specialist model) and 0.7%/3.6%/7.2% for random ranking. This shows that MOSAIC can outperform a specialist baseline in experimental settings despite not explicitly trained on experimental spectra.
W4. Scaling-study impact and distribution shift
We agree that larger models fitting QM9S better is not necessarily prescriptive of a scaling law. We will remove the claim that the multimodal advantage compounds with model size. Compared to struct-only training, any-to-any training improves Acc@1 for the S/M/L model sizes by 1.95, 7.30, and 5.65 percentage points. Therefore, the "multimodal advantage" is non-monotonic with respect to model size. We will acknowledge this caveat in our revision.
Indeed, QM9S train and test data are similiar in distribution, so the results do not fully demonstrate broad chemical generalization, especially to larger molecules. We will acknowledge this limitation.
Regarding panel (d) in Figure 4, this is not an effect of giving the any-to-any model more spectral inputs. A modality selected as a target is withheld from context, so the any-to-any setting sees each spectrum as an input less often than struct-only. The matched rebuttal comparisons select each arm using its own best-validation checkpoint, so their gains are not caused by evaluating struct-only after its later decline. In addition, the submitted layer-wise probes achieve higher held-out molecular-property scores for any-to-any structure representations. Together, these results are consistent with auxiliary spectral targets improving the learned representations.
Contribution framing and submission category
Thank you. We appreciate the reviewer's fair assessment and the recognition of our contribution.
Q1. Independent timestep sampling
Our original motivation for independent timesteps was to create information asymmetry during multi-target training while retaining modality-specific noise schedules. Moreover, previous work reported independent timesteps outperforming shared timesteps (Section of 2.2.3 of Subramanian et al., 2026, arXiv:2602.20140).
We ran 3 new experiments: We trained three 400k-step M-scale Phase 2 models. All 3 models use the same Phase 1 checkpoint, UAE-3D, data, initialization, architecture, and evaluation. "Independent" is our original setting. The "shared-quantile" comparison changes only the dependence between simultaneous target timesteps. "Exact sharing" is a secondary control that also removes modality-specific schedule offsets.
Shared-quantile coupling applies only when multiple modalities are targets. It draws one standard-normal value z and sets each modality timestep to
t_m = sigmoid(μ_m + z), preserving each modality's schedule while synchronizing relative denoising progress. Structure retains μ = 0, spectra retain μ = 2, and single-target examples are unchanged. Exact sharing instead assigns the same numerical timestep to every simultaneous target, removing modality-specific schedule offsets.Interestingly, both coupled variants substantially outperform independent sampling on structure generation. Shared quantiles also improve mean spectral cosine in all three evaluated joint directions. Independent draws can reverse the intended cleaner/noisier ordering across modalities, whereas shared quantiles preserve that ordering while retaining modality-specific schedules. Exact sharing matches joint-inference timing more directly but deteriorates structure→spectra cosine. Shared quantiles therefore provide the better overall trade-off.
Indeed, the reviewer's concern is supported by empirical evidence. We will report shared-quantile coupling as the preferred timestep rule in our revision. Thank you so much for pointing this out!
On stability, all losses remained finite across 8,040 logged training points per arm. Median pre-clipping gradient norms were 1.045, 0.968, and 1.043 for independent, shared-quantile, and exact-shared sampling, with corresponding p95 values of 1.712, 1.615, and 1.707. Independent sampling produced 11 rare infinite-norm events, versus 7 for shared quantiles and 3 for exact sharing. These diagnostics show no systematic divergence, although one seed cannot rule out subtler stability differences. Our evidence for coupling therefore rests on generation quality rather than a demonstrated stability benefit. We thank the reviewer for motivating this experiment.
L1. Discussion on computational cost
For training, UAE-3D and Phase 1 are reusable one-time costs of approximately 12 H100 GPU-hours each. At a fixed 400k-step Phase 2 budget, S/M/L/XL require approximately 52/72/130/175 GPU-hours. The checkpoint underlying the 298M model was reached after approximately 48 wall-clock hours on four H100s, corresponding to approximately 190 aggregate H100 GPU-hours.
For inference, 50 Euler steps require 100 network evaluations with CFG and 315 ms/mol amortized over batch 64 on one H100, excluding final UAE-3D decoding. DiffSpectra reports 1,000 steps and 469 ms/mol, so 20× refers to integration steps while MOSAIC's wall-clock time is 1.49× faster than DiffSpectra.
We will acknowledge these details in the revision.