- Rating
- 3
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 2
- Significance
- 1
Read review
Summary
This paper introduces GlycoGen, a model designed to predict glycan structures directly from MS/MS spectra. The authors note that the current sota model, GlycoBART relies on AR decoding via beam search, making it difficult to meet the throughput requirements of real-time LC-MS/MS annotation. To address this, the authors propose GlycoGen, a flow matching model based on Discrete Flow Matching, paired with a novel inference-time sampler called Crystallizing Flows.
Strengths and weaknesses
Strengths:
-
The problem is clearly defined, and the motivation is for the application. The paper specifically targets the throughput bottleneck associated with real-time annotation in LC-MS/MS. The authors link the computational cost of AR decoding to the instrument's acquisition rate of 100–200 Hz.
-
The speed advantage is striking. The rates of 21883 spec/s at K=1 and 4975 spec/s at K=8 are both well above the real-time requirement of 100–200 Hz; this lends practical engineering credibility to the paper's claim regarding "real-time inline annotation."
Weaknesses:
- The necessity of improving inference speed has not been clearly justified. There are numerous ways to enhance the speed or throughput of AR methods, such as increasing GPU resources or batch sizes, or modifying beam search parameters,yet the rationale for designing a specific method solely for speed improvement remains unclear.
Furthermore, the necessity for real-time annotation has not been adequately explained, given that MS-based mass spectrometry is inherently a high-throughput technique.
-
code is not available
-
The experimental section is not solid. The relative performance gains are modest, and the method fails to clearly outperform MDLM or AR. Furthermore, as the authors conducted only single-seed experiments, the statistical significance of the improvements was not adequately assessed.
-
paper is hard to follow. The topic addressed by the author is relatively niche and unfamiliar to most people in the AI community. Many technical terms appear without explanation, and the background information provided is insufficient.
Questions
Question:
- Is the ‘AR seq2seq’ mentioned in the experiments a Transformer model? If so, does this imply that the model represents only a minor improvement over the Transformer, with no significant gains?
Limitations
The experimental section is insufficient and limited to a small number of data scenarios.
Paper formatting concerns
no
Final justification
Thank author for the detailed rebuttal and additional experiments.
The response resolves the code-availability concern and clarifies several aspects of the evaluation. However, two central concerns remain. First, the real-time claim is not yet demonstrated under the most relevant latency setting. Second, the performance improvement is modest under strictly controlled conditions.
Overall, the rebuttal strengthens the submission, but the necessity of the proposed approach, the real-time claim, and the precise method contribution to the reported performance gains are not yet fully established.
I therefore maintain my Borderline Reject rating.
Meta-review
This paper introduces GlycoGen, a Discrete Flow Matching model for glycan structure prediction from MS/MS spectra, together with Crystallizing Flows, a deterministic simplex-propagation sampler with adaptive token commitment and early exit to speed up inference. The paper evaluates the method on CandyCrunch v2 under a run-stratified, per-spectrum protocol and includes extensive comparisons against alternative architectures including GlycoBART and a matched-architecture autoregressive Transformer, and several alternative sampling strategies.
I read the reviews, author responses, and additional rebuttal experiments. The rebuttal substantially strengthens the paper with additional empirical validation: the authors provide three-seed retrains of all models, evaluate performance separately on seen versus genuinely unseen glycan structures, report end-to-end single-spectrum latency, and analyze performance across and under held-out instrument types. They also appropriately narrow several claims, withdrawing the stronger “de novo” generalization claim, limiting Pareto dominance to the low-NFE regime, and tempering the original speed framing.
The reviews were mixed, reflecting differing judgments about the significance of this narrower contribution and the strength of the real-time deployment motivation. In particular, some reviewers remained concerned that the improvement over the strongest matched baseline is moderate and that the highest-accuracy configurations do not fully satisfy the strictest real-time latency targets. At the same time, the rebuttal directly addressed most of the concrete experimental concerns raised during review, including multi-seed robustness, structure-level generalization, instrument dependence, and measured latency, and the authors appropriately revised claims where the new evidence did not support the original framing.
Overall, I find the resulting contribution narrower than the original presentation but still technically solid and worthwhile. The method is simple, the controlled experiments are extensive, and the rebuttal directly addressed the most important concerns raised by the reviewers, including several with negative results that clarify the scope of the work. While questions remain about the practical importance of strict real-time annotation and the gain over the strongest matched baseline is moderate, I believe the combination of improved accuracy, substantially reduced sequential decoding cost, and empirical validation is sufficient for acceptance. I therefore recommend acceptance.