- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 2
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper tackles anatomical segmentation on 3D surface meshes, where models must be robust to both arbitrary patient pose and variation in mesh resolution. The authors propose EAMS, a lightweight (<2M parameter) segmentor built on Equivariant Mesh Neural Networks that combines intrinsic geometric descriptors with anatomy-aware PCA-derived coordinate frames for global context. It further introduces two complementary message-passing extensions trained with several auxiliary regularization losses. The method is evaluated on three clinically distinct tasks spanning edge-, face-, and vertex-level supervision (liver surfaces, intraoral scans, and intracranial aneurysms), against point-cloud and mesh baselines under both canonical and rotated inputs.
Strengths and weaknesses
Strengths
This paper identifies a genuine and underserved problem: segmenting anatomical surface meshes in a way that is simultaneously robust to patient pose and to wide variation in mesh resolution. The authors evaluate across three clinically distinct datasets that span edge-, face-, and vertex-level supervision, compare against several relevant baselines. On clarity, the paper is well organized and pairs its equations with helpful intuition, and the explicit limitations section aids understanding. On significance, the unified multi-task benchmark gives the community a useful reference point and a parameter-efficient framework to build on. On originality the anatomy-aware frame construction within an equivariant backbone is an inspring idea.
Weaknesses
The principal weakness concerns originality. Most of the core ingredients like equivariant mesh networks, intrinsic descriptors, and the assortment of regularization losses, are drawn from existing work. The rationale for the two augmented message passing modules and the regularization losses are underspecified. In addition, it is not quite clear how frequently large pose perturbations actually occur in clinical scenarios, and the robustness advantage is to some degree rather than a new capability. This raises the concern of fair comparison that baselines maybe tested under rotations they are simply not built to handle. On clarity, many system details are deferred to appendices, so the main text alone would have risk about faithful reproduction.
Questions
-
The paper uses SRA and VN generically as ways to extend the receptive field, but it does not clearly articulate when one should be preferred over the other. The result is that SRA and VN read as parallel options validated post hoc by which task they happen to win on, rather than as a principled, jointly-motivated design.
-
The regularization losses are assembled from established objectives, but this lacks an articulated account of how the terms interact, so it is hard to tell whether the combination reflects genuine insight or accumulated engineering. An ablation that turns off each regularization term individually to show their individual contributions and sensitivity to their weights could provide more evidence about the such combination.
-
How do the EAMS variants compare against the baselines when the baselines are given rotation augmentation during training? How does the current experiment set up ensure fair comparison?
Limitations
yes
Paper formatting concerns
No
Final justification
After carefully reading the rebuttal, I maintain my original rating.
Meta-review
This paper studies whether one lightweight equivariant mesh network can deliver pose-robust anatomical segmentation across several anatomies and supervision types. It received one accept and two borderline accepts.
I have read the authors' response, and it resolved the fairness question that drove my initial meta-review. The authors retrained every non-equivariant baseline with the same rotation augmentation, splits, and model selection as their own model. Matched augmentation improves the baselines, but it does not close the gap: at 40 degrees the strongest augmented baselines stay well below the equivariant model on the aneurysm, intraoral, and liver tasks. So the reported robustness is not an artifact of unequal augmentation. The authors also added a factorial ablation with a parameter-matched control that separates the module gains from added capacity, a pose diagnostic that explains the liver trade-off, and a stability analysis of the anatomy-aware frames. The borderline-reject reviewer raised the score and credited the matched-baseline result directly.
I recommend acceptance. This is a useful and honest multi-anatomy robustness study with a compact model, and the central claim now rests on a fair comparison.
The authors should fold the matched-baseline results and the factorial ablation into the paper, separate the exact-invariance claim on the aneurysm task from the approximate-canonicalization results on the dental and liver tasks, and release the code and preprocessing as promised.