- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 2
- Quality
- 3
- Significance
- 2
Read review
Summary
The paper studies a tri-level defender-attacker-operator (DAO) grid-security game: a defender hardens lines, an attacker interdicts lines, and an operator minimizes load shed via OPF. The authors reformulate this min-max-min problem into a single-level problem by repeatedly dualizing inner levels and using Big-M to linearize bilinear terms. The DC case yields a single-level MILP; the AC case uses an SOCP relaxation and yields a single-level MICP. Theorems (Thm 5.1/5.2/5.4) claim the single-level optimum S_SL is a conservative upper bound on the true tri-level worst-case load shed, with a safety certificate for the deployed defense. Table 3 on IEEE 14-bus DC validates the upper-bound property against exact enumeration and reports fast solve times (about 7–46 ms). An AC variant is shown on WSCC 9-bus.
Strengths and weaknesses
Strengths. This is the most mathematically structured paper in its line: the dualization + Big-M pipeline has explicit exactness theorems at each step. The DC part is genuinely validated — Table 3 confirms S_SL is a valid upper bound vs exact enumeration, and scalability figures show large speedups over enumeration/Benders-style baselines. The writing is clear and future work is candid about SOCP gaps.
Weaknesses. The headline claim — first certified single-level reformulation with AC in a tri-level game — is largely unvalidated. DC runs on 14-bus; AC runs on 9-bus, so even informal comparison is impossible. Table 4 reports SOCP relaxation values, not true AC OPF; the SOCP-true-AC gap is never measured. Table 4 also has no baseline, no runtime, and no DC-vs-AC comparison on the same system — yet "AC is worth it" and "fast single solve" are central motivations. Without (i) evaluating DC-derived and AC-derived defenses under one common true-AC power flow (e.g., MATPOWER), (ii) measuring SOCP vs true AC gap, and (iii) AC runtime at 14/30/57 buses, removing the unvalidated AC part leaves mainly a faster known DC upper bound.
The safety certificate is proved inside the SOCP model, not on true nonconvex AC. Relaxing the attacker upward helps conservatism, but SOCP can underestimate damage for a fixed attack — so S_SL >= true-AC worst case is not automatic. This matters most where the paper argues AC is needed (high-stress post-attack conditions), where SOCP is often loosest.
Other gaps: Big-M values are not specified or justified, yet exactness and the "7–50 ms" speed claim depend on M; Table 4 generation cost is non-monotonic in D (2947.96 -> ... -> 8991.25 at D=3 -> 6505.94) with no explanation; Table 3 conservatism can reach about 2x (A=2, D=2: true 6.1 vs bound 12.5) despite calling the gap "small."
Questions
(i) Your main novelty is embedding AC in the tri-level game, but DC is on 14-bus and AC on 9-bus — no apples-to-apples comparison. Table 4 is SOCP, not true AC, and has no baseline or runtime. Please: (a) evaluate defenses from DC and AC reformulations under the same true-AC power flow (MATPOWER); (b) report SOCP vs true-AC gap; (c) run AC to 14/30/57 buses with runtime. This directly tests whether AC is worth the added complexity.
(ii) Please clarify conditions under which each dualization step is exact. What happens when inner problems are nonconvex (true AC-OPF)? Which guarantees (upper bound, certificate) hold only under SOCP/convex inner models vs true AC? A explicit statement of what is proved for nonconvex inner OPF would clarify scope.
(iii) Table 4, As D increases, generation cost goes 2947.96 -> 3252.21 -> 3533.50 -> 8991.25 -> 6697.50 -> 6505.94, with a sharp jump at D=3. Since the objective combines load shed and quadratic generation cost, please explain this behavior (different SOCP operating points, Big-M/numerical effects, or suboptimal MICP solve).
(iv) What value of Big-M. is used, how is it derived from variable/dual bounds, and how sensitive are bound quality and solve time to M? Without this, exactness of the bilinear linearization and the reported speed are hard to assess, especially in the AC/SOCP setting.
(v) On 9-bus, does S_SL upper-bound worst-case load shed under true nonconvex AC-OPF for all binary attacks on d_SL? If not, please scope "certified" to "within the SOCP model."
Limitations
Limitations should front-load that AC results are SOCP-only on 9-bus with no DC comparison; the certificate may not transfer to true AC; conservatism can be large (Table 3); and Big-M choices are undocumented. Future work mentions some of this but it should be in the main limitations with deployment scope.
Paper formatting concerns
no
Final justification
Thank you for the clarifications. The concerns regarding the Big-(M) construction, certificate-gap reporting, DC certification, experimental scope, and notation have been largely addressed.
One major issue remains. The comparison on the IEEE 9-bus system does not establish that the SOCP-based certificate is valid for the original nonconvex AC model, especially under stressed post-attack conditions. Please clarify whether “exact AC-OPF” is globally solved and, unless stronger evidence is provided, state explicitly that the AC certificate applies only to the SOCP-relaxed model.
Finally, future responses should reproduce all substantive answers directly. Reviewers are not obligated to search across separate response threads referenced only by labels.
Q(i)
(a) Please check our response to Q3 of Reviewer 3m6F, where we have discussed this.
(b) We have evaluated the gaps (see our response to W3 of Reviewer 3m6F)
(c) Similar to Table 4 and our response in Q3 of Reviewer 3m6F, we run tri-level AC-OPF benchmarking (with only load shed as objective) on IEEE 14, 30 and 57 bus systems with A=2 and D=0,1,2,3 to obtain the following results:
IEEE 14-bus:
IEEE 30-bus:
IEEE 57-bus:
In every case, our SL-MICP formulation gives results close to the true values and the certifiicate $d_{SL}^* $ remains reliable.
Q(ii)
To state the scope explicitly: every dualization step is exact only for convex inner models (Lemmas 2.1/4.1 (LP) and 2.2/4.3 (SOCP) supply the strong duality used in Theorem 5.1), and no guarantee is claimed for a nonconvex inner AC-OPF. What is proved: (upper bound + certificate) hold unconditionally for DC; and for AC they hold with respect to the relaxed SOCP operator model.
In practice, the SOCP relaxation is tight on our benchmark (see our response to W3 of Reviewer 3m6F), where the exact AC-OPF and SOCP attain the same objective with nearly identical dispatch and voltage profiles. We will add an explicit statement after Theorem 5.4 to clarify the scope of the guarantees.
Q(iii)
The non-monotonicity is model behavior, not a numerical artifact. The defender minimizes the worst-case mixed objective (shed + cost) (lines 106 to 111), so generation cost need not be monotone in D for three compounding reasons visible in Table 4 itself: (1) the worst-case attack changes with D (column 3: the attacked pair is different in every row), so consecutive rows evaluate cost on different surviving network topologies; (2) because shedding dominates the weighted objective, the defender deliberately buys shedding reductions with expensive dispatch: at D=3 shedding drops 97.3→66.1 MW precisely by pushing the surviving network to costly operating points on the quadratic cost (eq. (5e)), producing the jump to 8991.25; (3) at D=4,5 the additional protected lines (1--4, then 8--2, 9--4) restore cheaper delivery paths, so cost falls again while shedding continues to 0.
Also generation cost only depends on power generation, and we do not assume any defence cost (hence increase in number of defence should not be assumed to directly increase generation cost).
Q(iv)
We have discussed this extensively in our response to W3 of Reviewer L6eE: for DC, we can set Mλ=Mϕ=1, which is valid by Lemma R1: unit shedding penalty and the shedding slacks guarantee feasibility for every topology by Lemma 2.1. My=maxi,j(θimax−θjmin) from the constraints in eq. (2a)/(39); for AC, Mx=max(∣xmin∣,∣xmax∣) componentwise from the constraints in eq. (5a)/(17). On sensitivity: for any M at or above these valid thresholds, the linearization is exact (Definition A.4), so the bound value is M-independent in the valid regime; solve-time sensitivity and the envelope-activity check will be reported per system in the revision. The reported 7--50 ms runtimes were obtained with the constants above, not with loose ad-hoc values.
Q(v)
As we have discussed in Q(ii), we do not theoretically claim that SSL automatically upper-bounds the true nonconvex-AC worst case; "certified" will be scoped to "within the SOCP model".
As our SOCP relaxation is tight (see our response to W3 of Reviewer 3m6F), we empirically get better results where SSL (shedding due to the relaxed attacker under defense $d_{SL}^* $) always gives an upper bound to the true optimal shedding S∗ (as observed in Table 3, Figure 2 from the mnuscript and the results shown in response to Q3 of Reviewer 3m6F and response to Q(i).(c) above)