acceptodds
Published as a conference paper at NeurIPS 2026

Act, Validate, Adapt: Closing the Causal Discovery-Control Loop

Taqiya Ehsan, Shuren Xia, Jorge Ortiz

Abstract

Every control action on a physical system is already a do-operator intervention, yet causal discovery and control are typically treated as separate stages. This separation leaves deployed controllers unable to test whether the causal graph they rely on remains valid under changing operating conditions. We present PolicyGRID, a closed-loop framework that uses actuator interventions to validate candidate causal edges, fits a structural causal model over the validated graph, and reuses that graph for both policy optimization and latent-regime monitoring. In a multi-actuator physical simulation with latent operating regimes (building energy management), interventional graph validation reduces closed-loop energy use by 21% at a standard comfort target relative to an otherwise identical observation-only graph, while improving four-way latent-context identification from 61.2% to 80.8%. A targeted ablation shows that the gains originate in graph pruning. Validation removes 16 of 47 candidate edges; with coefficient training held fixed, the validated graph reduces closed-loop energy relative to the unvalidated candidate set, while refitting coefficients on the same graph does not. On a live physical testbed, the same pipeline runs without code changes, performs 21 physical interventions, discovers 16 edges, and produces a target-responsive control policy where the observation-only baseline is insensitive to the comfort-energy target. These results show that physical controllers can use their own actions to validate causal structure and improve downstream control under latent regime shifts.

Keywords:
Atlanta, Main Track

Reviews

Among:
Shape:
123456this paper, Bottom 4%
Figure 1. Mean review rating of the reviewed papers at NeurIPS 2026. This paper averages 3.67 over 3 reviews, above 4% of the others.
Reviewer_3b1wOpenReview ↗
Rating
3
Clarity
3
Confidence
3
Originality
2
Quality
4
Significance
2
Read review
Summary

The paper presents a framework that integrates causal discovery and multi-objective control. The environment is represented as a directed graph modelling the relationship between (predefined) variables. The graph topology is discovered by starting from a set of candidate edges proposed by an ensemble of hypothesis generator mechanisms, including an LLM. For edges whose source is a controllable actuator, the framework tests the validity of the proposed relationships through targeted interventions using the same action variables later used by the controller. Edges whose source variable cannot directly be set by the controller, such as exogeneous and latent variables, are kept only if multiple discovery methods hypothesis generators propose it and the adjusted partial correlation remains large.

The resulting graph (Structural Causal Model) is used for two downstream purposes in the use case of building energy management: optimizing a user satisfaction–energy tradeoff policy and monitoring latent operating regimes through regime-specific prediction errors. Importantly, the graph topology is fixed across regimes; only the fitted coefficients vary by regime.

The framework is evaluated in multiple building automation scenarios from various sources: generated by the authors through building energy simulation software, existing real building-energy dataset and a small live office testbed. The experiments compare the framework against several causal-discovery and control baselines and include ablations on graph topology, coefficient fitting, intervention ordering, sensor dependence, and hyperparameter sensitivity.

Strengths and weaknesses

The reported results on various building automation scenarios demonstrate the added value of the approach. A key strength of the paper is the very extensive validation that has been executed. The framework is benchmarked against a lot of other methods, parameter sweeps are reported and many ablation studies are reported.

The intervention design is tailored to low-risk building automation, where actuators do not use physical harm, are reversible, and have measurable effects on a short-or-medium horizon. I see several factors in the framework that might hamper generalization to other domains. First, the decision on which edge to validate is simply based on the ratio of disagreement between the different hypothesis testers. No check is performed on possible consequences of taking the action corresponding to the source of the edge under validation. Second, multiple trials are needed before validation. This assumes that the environment is static. Third, and most fundamentally, the graph nodes are predefined variables that carry semantic meaning.

In the introduction, the authors mention "process control and robotic manipulation" as other application domains, but these domains require a safety check on executed actions, are typically highly dynamic scenarios, and have high-dimensional states that are difficult to interpret. The scope of the proposed framework seems therefore limited to me and highly tailored towards building automation. In that sense, the contribution may be more systems integration than a fundamentally new ML/causal/control algorithm.

In terms of clarity, I found the paper very densely written. Some details might be moved to appendix, e.g. on statistical tests and in section 5.3 the discussion is very quantitative whereas the paper would benefit from a more qualitative approach.

Questions

Regime tracking is important to the paper’s claimed novelty and system-level integration, but the strongest empirical control gains appear to come from interventional graph pruning. Section 4 says the policy optimizer uses one global validated graph and coefficients, while the regime monitor uses regime-specific coefficients. The paper is not fully clear that regime posterior estimates directly improve the control action in the main closed-loop result. To what extent does regime monitoring improve control? Also, given the availability of training datasets or simulators is required for bootstrapping the framework, couldn't you train simple supervised classifiers for the latent variables?

Lastly, the paper compares PC/SAM/VARLiNGAM/LLM as standalone baselines, but does not clearly quantify their marginal value inside the framework. It would be interesting to evaluate which of those baselines have the most complementary value.

Limitations

yes

Paper formatting concerns

none

Final justification

My biggest concern is still related to the scalability of the method. The paper seems to fall in the middle between a theoretical advancement and a use-case oriented approach.

Despite these concerns, I have increased my score from 2 to 3, because during the rebuttal many of my questions were answered in an adequate manner.

1 comment

We thank the reviewer for a careful, thought-provoking review; both questions identified real gaps, and we answer them below with new analysis and experiments.

Q1a (to what extent does regime monitoring improve control?). We ran the isolating experiment for this question during the response period: static, regime-aware, true-regime-oracle, and random-switch policies, all four on the same validated graph, three seeds × three comfort targets, under common random numbers (identical exogenous simulator disturbances across arms), so the arms differ only in whether and how regime-conditioned coefficients are selected. The answer: switching yields no detectable control benefit — RegimeAware - Static gives ΔMO = -0.0001 ± 0.0001 (p = 0.08, 0/9 cells favor switching), and even the true-regime oracle shows no detectable benefit over static (p = 0.17). This is a stand-alone result; we note for precision that Table 1's rows vary coefficient training data with the switching machinery held identical, so Table 1 does not test switching and we do not cite it as confirmation. The control gain is carried by the validated candidate set (Table 1: swapping it moves closed-loop cost by 6.51 kWh at ε=1.0 — the paper's 21% energy difference), while the monitor's role in the deployed loop is detection and attribution: regime identification (80.8% combined, §5.1) and calibrated posteriors usable as alarms (Brier 0.016/0.087), obtained from the same SCM at no additional interventional cost. We agree §4/§5 leave this division of labor implicit, and we will state it explicitly in §4.3.

Q1b (why not supervised classifiers for the latent variables?). We ran this comparison during the discussion: logistic regression and a small decision tree, trained on the same labeled regime partitions (Appendix B.2), scored on the same fresh test episodes as the monitor. The findings corroborated with the reviewer's instinct: feature-matched to the monitor's own six sensor variables, the classifiers clearly exceed the monitor on 4-way classification (logistic regression 90.0%, tree 79.7%, vs. 67.1% for the monitor; with all 13 observables the classifiers score 67.5/68.6 vs. 67.3; classifier performance was sensitive to the feature set). Our monitor uses labeled regime partitions at commissioning, as a supervised classifier would; a lightweight classifier is the better pure regime detector on this system, and we claim no classification advantage. The monitor's role is model-based attribution: the same SCM supplies per-regime predictive models whose regime-specific prediction errors localize which dynamics changed — which classifier output alone does not provide. We will add the full comparison (both feature sets) to the appendix and scope §4.3's claims accordingly.

Q2 (marginal value of each generator inside the union). We ran this ablation: leave-one-generator-out over {PC, SAM, LLM, VARLiNGAM} plus a PC-only minimal variant, three seeds, identical validation and monitoring protocol, on both the primary environment (15 variables) and the regime-stress environment (8 variables).

ConfigPrimary F1Primary mon. %Regime-stress F1Regime-stress mon. %
Full union0.431 ± 0.03367.0 ± 10.60.218 ± 0.09572.8 ± 33.5
−PC0.346 ± 0.01563.6 ± 7.00.296 ± 0.00037.2 ± 8.7
−SAM0.393 ± 0.00968.2 ± 11.80.323 ± 0.03525.0 ± 0.0
−LLM0.286 ± 0.02759.1 ± 1.30.201 ± 0.02929.6 ± 5.6
−VARLiNGAM0.373 ± 0.02462.1 ± 4.50.235 ± 0.03725.0 ± 0.0
PC only0.262 ± 0.03774.2 ± 21.8(monitor unbuildable)

Marginal value shows up differently for discovery than for downstream use. For discovery, on the primary environment the full union outperforms every leave-one-generator-out condition and the PC-only variant (F1 0.431 full vs. 0.346 without PC, 0.286 without the LLM, 0.262 PC-only), and the generators' proposal pool feeding validation shrinks from roughly 130 edges to 25, which also collapses the non-intervenable rescue path that requires multi-method consensus. On the primary environment the generators are complementary rather than redundant: each proposes ground-truth edges no other finds (unique true candidates per seed: LLM 5.3, SAM 4.7, VARLiNGAM 2.3, PC 0.7), and the final validated set retains edges from all four; the -VARLiNGAM row falls in each of the three paired seeds (by 0.009, 0.041, and 0.125 F1), a consistent direction whose paired confidence interval nonetheless includes zero at three seeds. VARLiNGAM itself degenerates on raw observational data (exact collinearity among the derived outputs) and contributes through the discovery loop's re-fits on intervention-augmented data: the loop repairs one of its own inputs, the paper's mechanism in miniature. For downstream use, the regime-stress environment is where the union earns its cost: removing any single generator leaves F1 roughly flat (several removals are nominally higher, within seed noise), yet monitoring accuracy collapses by 35 to 48 points, a decline consistent with losing the regime-sensitive edges the monitor depends on, and the PC-only variant cannot be deployed at all: on this environment PC proposes no parent for zone temperature in any seed (this failure occurred in all three tested seeds), so the monitor cannot be built. This reproduces the paper's central dissociation inside the component ablation itself: downstream utility tracks the validated union's coverage, not its F1. One protocol note: all configurations in the grid share one protocol (seeds, validation, monitoring evaluation), so every comparison in the table is paired; the grid is not a re-run of Tables 7 or 9 and its absolute levels should not be compared against them. Full table will be added to the appendix.

On "systems integration rather than a fundamentally new algorithm." We accept that edge testing by intervention is not new in isolation — DODO contains the closest test-and-prune primitive — and we accept the scope criticism that accompanies the comment (below). What we claim as the contribution is the operational coupling and its measured consequences: control actions are reused as do-operator experiments under a composite acceptance test (K=10 trials, t-test at α=0.05, effect threshold, all-K sign consistency — per-edge false validation ≈ 0.2% under symmetric noise — with BH-FDR at 0.10 controlling false discoveries across the tested candidates, an operating characterization we derived during this discussion and will add to Appendix B with the power table), and the resulting graph is evaluated by its downstream monitoring and control utility rather than by GT recovery alone. The measured finding this coupling produces: unweighted graph F1 did not reliably predict downstream monitoring or control utility, because F1 treats inclusion and exclusion errors symmetrically while a control loop punishes them asymmetrically — the closed-loop gain tracks validation's false-positive pruning (Table 1) — and the loop runs end-to-end on a physical testbed.

On the three generalization blockers. (a) No safety check in ordering: correct. On hardware all validating actions are the controller's own actuators exercised within equipment ratings, but they remain deliberate experiments (maximum actuator settings), not actions the controller would ordinarily select, and no safety or cost term is implemented in the ordering rule — we present that as future work, not a present capability. The present deployment boundary: low-dimensional systems with few actuators, reversible bounded actions, large quickly observable effects, stable conditions, and no safety-critical exploration. (b) Static environment during validation: stationarity is required over each edge's validation trials rather than globally — and, to be precise about the statistics, the pooled t-test assumes the per-trial effects are drawn from a comparable distribution across the full trial set (minutes per edge in simulation; a few hours per actuator on hardware), an assumption we will state explicitly alongside the protocol. (c) Predefined semantic variables: agreed, and this is a genuine scope boundary — the framework assumes a variable-level state abstraction, which cyber-physical system deployments provide (sensor/actuator schemas) but raw high-dimensional perception does not. We will state this assumption explicitly in §3.

On the introduction's mention of process control and robotic manipulation. The reviewer is right, and this is our clearest overstatement: these domains carry requirements (safety screening, fast dynamics, high-dimensional state) our current framework does not meet. We will remove them from the introduction and scope the claims to variable-level cyber-physical systems with reversible, bounded actuators. Within that scope, the evidence is replication across related building-control settings, not cross-domain generality: the validated-vs-observational closed-loop comparison, repeated on two further single-zone building simulators with static policies so that only the graph differs, reduces energy in all 49 of 49 paired seed×ε cells (satisfaction matched on smart_room; an energy-direction replication on smart_room_hidden_vars), and discovery and monitoring span six building environments and the physical office testbed (Tables 7, 10; closed-loop table to be added to the appendix). These are robustness replications within one problem family; transfer to high-dimensional robotics, industrial process control, or multi-zone commercial systems is untested, and we will say so.

On clarity. We agree: in revision, §5.3's statistical detail moves to the appendix with a qualitative summary in the main text, and statistical test details throughout move to captions and appendix.

Reviewer_Bvx4OpenReview ↗
Rating
3
Clarity
3
Confidence
3
Originality
2
Quality
2
Significance
3
Read review
Summary

This paper proposed PolicyGRID which can connect the causal discovery and control. It uses the execution action "do-operator" to physically verify candidate causal edges and use the verified graph to optimize the policy and monitoring of potential operating conditions. In the simulation and physical enviroment, compared with observation-only graphs, it reduce the energy cost about 21% and increase the operating condition recognition.

Strengths and weaknesses

strength:

  • it migrate the experiments from the simulation to the real environment and the hardware experiments is one contribution.
  • the design of ablation is useful to show why it is useful like the improvement is from the pruning instead of re-training, which can provide a clearer guidance for readers who would implement it.
  • it provides some application boundary for readers and analyze why this method doesn't work under some special circumstance and provide true techinical application value.

weakness:

  • the experiments evidence is not strong to support it can be migrate into more complicated senerio like multi-zone and commercial systems ...
  • no reproductivity evidence to show it can be perfectly reproduced
  • limited novelty, all the 4 generators are existed and it is more like a composition of existed parts/methods/models.
Questions

see weakness

Limitations
  • The author didn't verify the cross-disciplinary universality and need to extend the experiments into more other domains to show the generalization ability
  • The writing can be further improved like several paragraph are inserted into results numbers which is not the best way to demonstrate the results
Paper formatting concerns

limited contribution

1 comment

We thank the reviewer for carefully identifying three concrete gaps in our evidence. We address each below.

W1 (evidence does not support migration to more complex scenarios). There are two parts to this answer. First, within the paper's scope, the central mechanism now has additional replication evidence across related building-control settings: the validated-vs-observational closed-loop comparison, repeated on two further single-zone building simulators with static policies so that only the graph differs, reduces closed-loop energy in all 49 of 49 paired seed×ε cells (−7.4% on smart_room with satisfaction matched; −6.6% on smart_room_hidden_vars as an energy-direction replication); discovery and monitoring already span the six evaluation environments and the physical testbed (Tables 7, 10). We will add the closed-loop table to the appendix. Second, we agree the paper does not demonstrate multi-zone or commercial-scale deployment and does not claim to: §7 states the O(|A|·|V|) intervention scaling limits current deployment to systems of roughly fifty observable variables, and larger systems require hierarchical or modular discovery. The same boundary applies across domains: the framework assumes variable-level state and reversible, bounded actuators, which cyber-physical systems provide; we do not claim domains outside that scope. Our claim is the mechanism that do-operator validation of a discovered graph improves downstream control and monitoring, not building-control state-of-the-art at scale. We will sharpen this scope statement in the introduction.

W2 (no reproducibility evidence). We have released an anonymized repository containing: the full pipeline and all baselines, the JavaScript simulators and ground-truth graphs, all LLM prompt templates plus the per-seed candidate-edge caches, raw LLM outputs, and model identifiers with documented failure handling (the LLM path is stochastic at temperature 1.0, so exact replay comes from these saved artifacts rather than re-querying; proposals replay from the cache without an API key), per-seed discovered edge sets for every method, the exact seeds and configuration for every table, and a 68-check preflight diagnostic suite. Since responses cannot contain links under this rebuttal instructions, we have shared the anonymized repository link with the Area Chair; the AC can make it available to reviewers. The paper's main results are regenerable from a single per-seed pipeline entry point, and the per-seed artifacts, seeds, and configurations behind the released runs ship with the code. We verified the release by an end-to-end, API-free replay of a shipped run from a fresh checkout: discovery phase 1 is bit-exact, the validated graph reproduces 9 of 10 edges with no spurious additions (the one divergence traces to the LLM-designed intervention probe's deterministic fallback), and monitoring metrics match exactly given the same graph.

W3 (limited novelty — composition of existing generators). The four generators are deliberately off-the-shelf; they are not the contribution. The contribution is (i) the validation loop that treats the controller's own actions as do-operator experiments, with composite per-edge acceptance tests plus BH-FDR control across the tested candidates — a deployment in which the control loop itself supplies the interventional evidence for its world model, which we have not found demonstrated in prior work; (ii) the empirical finding that unweighted graph F1 did not reliably predict downstream monitoring or control utility: two methods beat our F1 on the primary environment yet collapse on monitoring and control (Table 7 vs. Table 9), because F1 weighs inclusion and exclusion errors symmetrically while a retained false positive is actively exploited by the policy; and (iii) closing the full discover–validate–monitor–control loop on physical hardware. The closest prior systems (FANTOM; CAASL; Cai et al. 2026; C-MBPO) each instantiate a subset of this loop; none closes it (Table 28).

On writing (limitations). We agree and will restructure the results presentation in revision: main claims first, statistics moved to captions and appendix, and §5.3's quantitative material condensed to a qualitative summary in the main text.

Reviewer_VDQiOpenReview ↗
Rating
5
Clarity
3
Confidence
4
Originality
4
Quality
3
Significance
4
Read review
Summary

This paper presents PolicyGRID, a closed-loop framework that connects causal discovery, interventional graph validation, structural causal modeling, regime monitoring, and policy control. The key idea is that actions taken by a controller are do-operator interventions and can be used to validate candidate causal edges. The validated graph is then used both for policy optimization and latent-regime monitoring. The authors evaluate the framework in smart-building simulations, real building data, and a live physical testbed, reporting improved energy use, better regime identification, and successful physical deployment.

Strengths and weaknesses

Strengths

  • The main idea is strong: physical controllers already intervene on a system, so those interventions can be used to validate causal structure before using it for control.
  • The paper has a clear closed-loop design. Candidate edges are proposed, tested through do-operator interventions, pruned, fit into an SCM, and reused for both control and regime monitoring.
  • The combination of causal discovery, graph validation, multi-objective control, latent-regime monitoring, and physical deployment is ambitious and useful.
  • The evaluation is unusually broad. It includes simulations, real building data, and a live office testbed.
  • The ablation separating graph topology from coefficient fitting is a strong part of the paper. It supports the claim that performance gains come mainly from graph pruning rather than just adding interventional data.
  • The results are practically meaningful. The reported energy reduction and improved regime monitoring address real deployment concerns in building control.
  • The paper is honest about some limitations, including scalability to larger systems, fixed topology for regime monitoring, and the lack of a sample-complexity bound.
  • The discussion about false-positive edges is useful. It explains why raw graph F1 may not match downstream control performance.

Weaknesses

  • The method is complex and has many moving parts: multiple discovery methods, LLM proposals, interventional testing, pruning, Ridge SCM fitting, Bayesian monitoring, and policy optimization. This makes it difficult to isolate which parts are essential.
  • The paper is long and dense. Some readers may find it hard to follow the full pipeline without carefully tracking many implementation details.
  • The claims of the paper are supported by the building-control setting, but it is unclear how well the framework transfers to other physical systems with faster dynamics, more variables, or more expensive interventions.
  • The intervention procedure scales as a function of actions and variables, which the authors acknowledge. This could limit deployment in larger systems.
  • The physical testbed result is valuable, but the diagnostic ground truth is expert-proposed rather than a true system-spec graph. This makes physical graph quality harder to interpret.
  • The use of GPT-3.5-turbo as an advisory component may raise reproducibility and stability questions, even though the paper includes guardrails.
  • The regime monitor assumes a fixed graph topology and detects coefficient shifts. It may miss newly appearing causal pathways unless discovery is rerun.
  • The paper would benefit from a clearer sample-complexity analysis for how many interventions are needed to validate edges with high confidence.
  • While the ablations are useful, the paper could present a simpler minimal version of PolicyGRID to show what is required for most of the benefit.
Questions
  • Can the authors provide a clearer analysis of intervention sample complexity? This would help determine when PolicyGRID is practical for larger physical systems.
  • Which components are essential for most of the gain? A simplified version without the LLM component or with fewer discovery methods would help clarify the minimal effective pipeline.
  • How would PolicyGRID handle systems where interventions are expensive, slow, or unsafe? Please clarify the deployment constraints under which the approach is expected to work.
  • Since the regime monitor assumes fixed topology, what happens when a new causal pathway appears under a new operating regime? Would the system detect this as model mismatch and rerun discovery?
  • Can the authors clarify the reproducibility of the LLM-guided parts? For example, are prompts, outputs, and candidate edges fixed or variable across runs?

My score could increase if the authors provide a stronger sample-complexity discussion and a clearer minimal ablation of the pipeline. My score could decrease if the interventional budget or LLM dependency makes the method difficult to reproduce or deploy outside the reported setting.

Limitations

The authors discuss limitations well. I would still recommend adding more detail on intervention cost, safety constraints, sample complexity, and how the method should be adapted when graph topology changes under new regimes. The LLM advisory role should also be described in a reproducible way with prompts and guardrails.

Paper formatting concerns

No major formatting or anonymity concerns noticed. The paper is dense and would benefit from some streamlining, especially around implementation details and ablation presentation.

Final justification

I reassessed the paper under the correct General contribution type. This places greater emphasis on methodological novelty and general technical significance than my original Use-inspired assessment.

The authors’ response substantially improves the paper through new component ablations, a clearer operating characterization of the intervention procedure, additional reproducibility evidence, and experiments isolating the roles of graph validation and regime monitoring. In particular, the evidence now supports the view that the principal contribution is the closed discovery–intervention–validation–control loop and the demonstrated downstream value of pruning false-positive causal edges, rather than novelty in the individual discovery methods.

The response also narrows several claims appropriately. Regime monitoring does not measurably improve control, supervised classifiers are better for pure regime classification in the reported setting, and the demonstrated scope is limited to low-dimensional cyber-physical systems with predefined variables and safe, reversible actuators. Concerns about broader applicability, intervention cost, and system complexity remain, but the reasons to accept now outweigh these limitations.

1 comment

We thank the reviewer for their insights and for stating explicitly what evidence would strengthen the paper; we provide it below.

Q1 (sample complexity). The validation primitive has a precise operating characterization. Each candidate edge receives K=10 do-operator trials; acceptance requires a two-sided t-test (α=0.05), a practical-effect threshold, and sign-consistency across all K trials, followed by Benjamini–Hochberg FDR (α=0.10) across candidates when ≥20 are tested in a round. Under symmetric noise, the sign-consistency gate alone bounds the per-edge false-validation rate by 2^−(K−1) ≈ 0.2% (Monte Carlo: 0.19%). Power analysis shows 80% detection at a per-trial standardized effect of d ≈ 2.0; K=10 is the smallest K that drives the sign-gate bound below 0.2% while retaining 80% power at d=2. The test is a high-specificity detector, and its recall-for-precision trade is the mechanism behind the paper's F1-vs-utility dissociation: a retained false positive is actively exploited by the policy; a suppressed weak edge merely fails to contribute (§6).

This characterizes the simulation protocol. The physical deployment used a reduced, per-actuator gate chosen for time cost — 7 trials per actuator (3 screening, 4 confirmatory; each trial yields a delta for every sensor), a resolution-level effect screen, a two-sided t-test at α=0.10, and BH-FDR at 0.10, with no sign-consistency stage — so its per-edge false-validation rate is bounded only by the t-test (α=0.10); BH-FDR controls false discoveries across the tested edges, not any per-edge rate — both substantially weaker than the simulation gate's 0.2%. The realized run's specificity came from effect magnitude: all 10 gate-validated (actuator-source) edges reached p ≤ 0.013; the observational rescue path added 6 non-actuator edges, marked separately in the released edge evidence. §5.3's "no hyperparameter changes" at deployment is therefore incorrect (K, α, and the sign stage changed); we will correct it in revision, report both operating characteristics in Appendix B, and scope the 0.2% figure to simulation.

Total budget is at most K × |tested candidates| — linear in the generator-pruned candidate set (measured: 1,576 interventions per seed on the primary environment; a 3-trial screen rejects ineffective candidates early), with worst case O(K·|A|·|V|), not O(|V|²). We will add this analysis and the power table to Appendix B; a distribution-free sample-complexity bound remains open (as §7 states).

Q2 (minimal pipeline). We ran the requested ablation: leave-one-generator-out over {PC, SAM, LLM, VARLiNGAM} plus a PC-only minimal variant, three seeds, identical validation and monitoring, on the primary (15-variable) and regime-stress (8-variable) environments.

ConfigPrimary F1Primary mon. %Regime-stress F1Regime-stress mon. %
Full union0.431 ± 0.03367.0 ± 10.60.218 ± 0.09572.8 ± 33.5
−PC0.346 ± 0.01563.6 ± 7.00.296 ± 0.00037.2 ± 8.7
−SAM0.393 ± 0.00968.2 ± 11.80.323 ± 0.03525.0 ± 0.0
−LLM0.286 ± 0.02759.1 ± 1.30.201 ± 0.02929.6 ± 5.6
−VARLiNGAM0.373 ± 0.02462.1 ± 4.50.235 ± 0.03725.0 ± 0.0
PC only0.262 ± 0.03774.2 ± 21.8(monitor unbuildable)

On the primary environment, the full union outperforms every leave-one-generator-out condition and the PC-only variant: F1 0.431 full vs. 0.346 without PC, 0.286 without the LLM (the largest single-generator drop), and 0.262 with PC alone, as the generators' proposal pool feeding validation shrinks from roughly 130 edges to 25 and the consensus rescue path for non-intervenable edges starves. On the regime-stress environment, the F1-vs-utility dissociation from the paper shows up inside the ablation itself: removing any single generator leaves F1 roughly flat (several removals are nominally higher), yet monitoring accuracy collapses by 35 to 48 points, a decline consistent with losing regime-sensitive edges the monitor depends on, and the PC-only variant cannot be deployed at all: on this environment PC proposes no parent for zone temperature in any seed or configuration (this failure occurred in all three tested seeds), so no predictive model exists to monitor with. On the primary environment the generators are also complementary: each proposes ground-truth edges no other finds (unique true candidates per seed: LLM 5.3, SAM 4.7, VARLiNGAM 2.3, PC 0.7), and the final validated set retains edges from all four. Per-seed note on -VARLiNGAM: F1 falls in all three paired seeds (by 0.009/0.041/0.125), though the paired CI includes zero at three seeds; VARLiNGAM itself degenerates on raw observational data (exact collinearity among the derived outputs) and contributes through the loop's re-fits on intervention-augmented data — the validation loop repairing one of its own inputs. Monitoring on the primary environment shows no detectable differences at three seeds; the discovery gradient is what that environment contributes. Protocol note: all grid configurations share one paired protocol; the grid is not a re-run of Tables 7 or 9, whose absolute levels are not comparable. Full table to the appendix.

Q3 (expensive, slow, or unsafe interventions). The characterization above gives the deployment criterion: validation is practical where a do-operation produces a response of d ≳ 2 within one washout window — the range that building actuators occupy. Three points bound the concern. First, the simulation-scale budget (1,576 interventions) would take over a month at hardware hold-and-washout cadence, so the physical protocol instead exercises each actuator jointly for all its candidate edges — 21 do-operator interventions over 11 hours, a commissioning-scale procedure. The credible hardware scope is small systems with few actuators and large, fast effects; validation uses only the controller's own actuators within equipment ratings. Second, the validation budget is spent once at deployment; afterwards diagnostic probes fire 5 times per episode and a passive-only fallback matches full accuracy at steady state (Appendix D.2). Third, at a fixed 500-intervention budget, disagreement-first ordering retains a 36% relative F1 gain (Table 17), so constrained deployments degrade gracefully. Safety-critical domains requiring formal action screening are outside the current scope; we will scope the introduction accordingly in revision. On transfer: the evidence is replication within the building-control family, not cross-domain — the validated-vs-observational closed-loop comparison on two further single-zone simulators with static policies (only the graph differs) reduces energy in 49 of 49 paired seed×ε cells (−7.4% smart_room, satisfaction matched; −6.6% hidden_vars, energy-direction); table to the appendix.

Q4 (new causal pathway under a new regime). The monitor distinguishes among known coefficient regimes on a fixed topology. A pathway absent from Ĝ raises residual error under every regime model, but the posterior is a relative comparison: normalization can still assign high confidence to the least-bad regime, and the implemented probe trigger fires on sustained high confidence, not on high absolute error. The current system therefore does not include a validated none-of-the-above detector or an automatic re-discovery trigger, and the regime-shift experiment (Table 18) tests transitions among known regimes with fixed topology, not new-edge appearance. We will state this limitation in §7 and investigate absolute-residual thresholds as the extension. Within the represented regime space, Table 18 shows detect-then-adapt (re-identification in 27 steps for occupancy, 193 for the slower window shift, 92.2% post-transition accuracy); the fixed-topology design is deliberate (coefficients vary by regime; data decide which edges discriminate).

Q5 (LLM reproducibility). The prompts are fixed, dataset-type-specific templates checked into the code; the LLM proposes edges from variable names and building-science context, with no data access. The LLM path is stochastic (temperature 1.0), so reproducibility rests on saved artifacts rather than determinism: per-seed raw proposals, parsed candidate sets, and the LLM edge cache are logged and ship in the anonymized repository (URL to the AC by Official Comment) with prompts and model identifiers, so the LLM's edge proposals replay from the cache without an API key. (Correction: the documented top-p 0.8 (Appendices G.2, H) covers edge proposals; intervention-design calls use the client default 0.9 — we will fix this in revision.) Every LLM proposal is then screened before reaching the policy: proposals with actuator or intervenable sources receive direct do-operator validation, while proposals from non-intervenable sources enter the observational rescue path (consensus + back-door-adjusted partial correlation, §4.1) — the wrong-prior stress test (Table 20) shows all five deliberately injected false edges are rejected before reaching the policy. On GPT-3.5-turbo: the LLM is advisory, and the wrong-prior test above measures the effect of bad proposals; a stronger model changes candidate quality, not the validation guarantee; LLM-only is reported as a standalone baseline (Table 7).

On the physical ground truth (W5). Agreed: the 14-edge diagnostic graph is expert-proposed, not a system specification, and the paper scores it as a diagnostic reference only — the physical evaluation's primary evidence is monitoring accuracy on real regime transitions (81.5%/91.3%, Table 10), independent of that graph.

On density. We agree the paper is dense. In revision we will restructure the results presentation: main claims first with statistics moved to captions and the appendix, §5.3's quantitative material condensed to a qualitative summary in the main text, and §4's implementation detail streamlined around the pipeline schematic.

Comments on the paper

1 comment
Meta-review

The paper is carefully evaluated and the physical deployment is a real strength. The main uncertainty is less about whether the system works in the reported setting, and more about what the main research contribution is beyond integrating existing components. The rebuttal should focus on the following points:

  1. Please clarify the novelty beyond system integration. Most individual components are established. What is the key technical contribution of PolicyGRID, and which components are actually necessary? In particular, it would help to quantify the marginal value of the ensemble discovery methods and the LLM component.

  2. Please clarify whether regime monitoring actually improves control. The paper currently seems to use one global SCM for policy optimization and regime-specific models for monitoring. Does the inferred regime affect the control action in the main results? If not, the closed-loop claim should be stated more carefully, and the advantage over a simpler supervised regime classifier should be explained.

  3. Please address scalability and deployment assumptions. The current validation requires repeated physical interventions and predefined semantic variables. How does the intervention cost scale with the number of variables and actuators, and what safety or stationarity assumptions are needed? What if the LLM system causality will change over the context window? This is important for understanding whether the method can move beyond small, slow building-control systems.

Current version needs clarification, slightly leaning toward rejection. A convincing response on these three points would substantially improve the case for acceptance.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.