- Rating
- 4
- Clarity
- 2
- Confidence
- 3
- Originality
- 2
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper proposes GridDiffuser, a constraint-guided graph diffusion framework for AC optimal power flow. The method represents the power grid as a graph with buses, generators, and branches, and uses an encode-process-decode GNN as the diffusion denoiser. At inference time, the model samples multiple candidate operating points and applies a constraint-guided correction based on a Levenberg-Marquardt-style clean-space update. The correction approximately minimizes power-flow residuals and thermal-limit violations using conjugate-gradient iterations with JVP/VJP products, avoiding explicit Jacobian formation. The paper evaluates the method on large PGLearn AC-OPF benchmarks with stochastic demand and N-1 perturbations, and reports improvements in several pre-power-flow and post-power-flow feasibility metrics over deterministic GNN baselines.
Strengths and weaknesses
The paper studies an important and practically relevant problem. Fast approximate AC-OPF under uncertainty and contingency perturbations is a meaningful application area, and physical feasibility remains a major bottleneck for learned OPF solvers. In this sense, the paper is well aligned with a use-inspired contribution: it attempts to adapt modern generative modeling and graph learning to the practical structure and constraints of power-system dispatch.
The graph formulation is natural. Explicitly modeling buses, generators, and branches matches the physical structure of power grids, and the use of generator availability masks is a sensible design choice that avoids learning irrelevant inactive-unit variables. The denoising architecture is also technically reasonable: edge states can encode branch parameters and operational limits, while the global virtual node provides a mechanism for system-level coordination. Residual connections and noise-conditioned adaptive normalization are appropriate choices for a diffusion denoiser.
A further strength is the inference-time constraint guidance. Instead of using a manually tuned gradient guidance step, the method uses a damped least-squares correction inspired by Levenberg-Marquardt updates. Solving the update approximately with conjugate-gradient iterations and JVP/VJP products is important for scalability on large grids, since explicitly forming or inverting the Jacobian would be expensive. The evaluation also goes beyond supervised prediction error by reporting pre-power-flow and post-power-flow feasibility metrics, which are more informative than only reporting MAE against IPOPT solutions. The use of thousand-bus systems, stochastic demand perturbations, and N-1 contingencies makes the experimental setting more realistic than small toy-grid studies.
However, I have several concerns that make the empirical case insufficiently convincing in the current version. First, the novelty is moderate. The method combines several existing ideas: diffusion sampling, graph neural networks for grid-structured data, Best@K candidate selection, and inference-time physics correction. This combination is coherent, but the paper does not sufficiently isolate what is new relative to prior diffusion-based OPF methods, especially DiffOPF. A direct comparison with DiffOPF or a closely matched diffusion baseline is important.
Second, the experimental comparison is incomplete. The main learned baselines are deterministic GNN and GNN+Constraint. Stronger and more diagnostic baselines are needed, including DiffOPF under the same protocol, deterministic GNN plus the same LM correction, GNN+Constraint plus Best@K selection where applicable, multi-start supervised baselines, and possibly warm-started classical OPF solvers. Without these comparisons, it is difficult to determine whether the gains come from diffusion modeling, multi-candidate sampling, or the inference-time correction.
Third, the contribution of each component is not fully separated. The final performance depends on diffusion sampling, (K=32) candidate generation, Best@K selection, projection, and LM guidance. Although the paper reports mean-vs-Best and guided-vs-unguided results, it remains unclear how much of the improvement is due to the learned diffusion distribution itself and how much is due to sampling many candidates followed by a strong feasibility correction. Some pre-power-flow results also appear counterintuitive: unguided GridDiffuser can be worse than GNN+Constraint on some violation metrics, especially thermal violations, while guidance improves the results by large factors. This suggests that the feasibility improvements may rely heavily on the LM correction rather than on the learned generative model. Fourth, the paper focuses heavily on constraint violations but does not sufficiently evaluate OPF objective quality. AC-OPF is an optimization problem, not only a feasibility problem. The paper should report generation cost, optimality gap relative to AC-IPOPT, and cost-feasibility tradeoffs. A solution with low violations but much worse generation cost may be less attractive in practice. Since the model is trained from IPOPT-generated supervision, it is also important to clarify whether it only imitates the distribution of IPOPT local optima or whether it can improve robustness or objective quality beyond the supervised solver distribution.
Fifth, the guidance procedure needs more analysis. The paper uses a fixed (\alpha_{\mathrm{LM}}=1), even though the Euler discretization suggests that a noise-schedule-dependent scaling may be appropriate. The empirical justification for this choice is limited. The method also uses a fixed number of CG iterations, but the paper does not report convergence diagnostics, residual tolerances, or sensitivity to the damping coefficient, guidance start step, and number of CG iterations. These details matter because failed or noisy CG updates could produce harmful corrections.
Finally, generalization remains limited. The experiments mostly train and test within the same grid topology distribution, with variations in operating conditions and N-1 perturbations. For a graph-learning method intended for power systems, generalization to new network topologies, new buses or branches, changed operating limits, and shifted load distributions is a central question. The paper also lacks statistical uncertainty reporting; the main tables do not include standard deviations, confidence intervals, or multiple random seeds, making smaller differences difficult to interpret.
The paper presents a technically coherent framework for graph diffusion with constraint-guided correction for AC-OPF. The results are promising, especially after Best@K selection and guidance. However, the current version does not yet provide sufficiently strong evidence that the main improvement comes from the proposed diffusion model rather than from multi-candidate selection and LM correction, and the lack of direct diffusion baselines, objective-cost evaluation, sensitivity analysis, and topology generalization substantially weakens the case for acceptance.
Questions
- How does GridDiffuser compare with DiffOPF under the same datasets, sampling budget, and post-power-flow evaluation protocol? This is important for establishing the novelty and practical advantage of the proposed diffusion framework.
- What happens if the same LM correction and Best@K selection are applied to deterministic GNN or GNN+Constraint baselines? This would help separate the benefit of diffusion modeling from the benefit of multi-candidate selection and inference-time feasibility correction.
- What are the generation-cost gaps relative to AC-IPOPT? Are the samples with lower constraint violations also near-optimal in objective value? Please report objective cost, optimality gap, and cost-feasibility tradeoffs.
- How sensitive are the results to (K), the number of diffusion steps, the guidance start step, (\alpha_{\mathrm{LM}}), the damping coefficient, and the number of CG iterations? Please also report whether the CG solver monitors residual reduction or convergence during guidance.
- Why does unguided GridDiffuser perform worse than GNN+Constraint on some pre-power-flow violation metrics, while guided GridDiffuser improves dramatically? Does this indicate that most of the feasibility improvement comes from the LM correction rather than from the diffusion model?
- Is the Best@K selection criterion fully available at deployment time? Does it require evaluating quantities that would be unavailable, expensive, or operationally unrealistic in real dispatch pipelines?
- Can the method generalize to unseen grid topologies, new contingency patterns, changed operating limits, or substantially shifted demand distributions? My evaluation would increase if the authors add a direct DiffOPF comparison, apply the same guidance and Best@K selection to deterministic baselines, report objective-cost gaps and statistical uncertainty, and show robustness to guidance hyperparameters and topology shifts. My evaluation would decrease if the gains are mainly attributable to LM correction or Best@K selection rather than the diffusion model itself.
Limitations
No. The paper should more explicitly discuss the limitations of relying on IPOPT-generated supervision, the possibility that the model imitates solver outputs rather than improving OPF quality, the dependence on inference-time correction, the lack of topology generalization, and the safety/fallback mechanisms required before deployment in real power-system dispatch.
Paper formatting concerns
I did not notice major anonymity or formatting violations. However, some figures are visually crowded or difficult to read, especially the denoiser illustration and runtime violin plot. Some table entries use inconsistent numerical precision, and the bibliography appears to contain outdated or incomplete metadata for some references.
Final justification
I raised score accordingly.
We thank the reviewer for the detailed assessment. We first address the most important concerns regarding insufficient baselines.
(1) Lack of comparison with DiffOPF
Thanks for raising this important point. We carefully studied DiffOPF, the closest AC-OPF work to ours. However, the two methods still differ substantially in formulation, conditioning, and post-processing, while key implementation and evaluation details of DiffOPF are not specified.
For this reason, we do not report a comparison with it. A faithful comparison would require reconstructing a different framework, with many key components determined by our own assumptions, making a reliable evaluation very difficult. Although we have not reported a DiffOPF baseline, we hope the comparison below provides a useful basis for assessing the method differences and the contributions of GridDiffuser.
(2) What happens if the same LM correction and Best@K selection are applied to deterministic GNN or GNN+Constraint baselines? Does the improvement in pre-PF evaluation come mainly from the LM correction rather than from the diffusion model?
We will address them together.
We report below the results of applying the same LM correction to GNN+Constraint. We agree that LM further improves this baseline in pre-PF evaluation, but not enough to surpass GridDiffuser. More importantly, it provides almost no gain in post-PF evaluation, which is more relevant to practical deployment than pre-PF evaluation.
Table 1: Effect of applying LM correction to baseline in Pre-PF evaluation. The maximum reduction is 18%, still far below the 78% achieved when applying guidance to GridDiffuser.
Table 2: Post-AC power flow feasibility. Here, we use K=64 rather than K=32 as in the main paper to reduce sampling variability. Cost gap is computed as $ |Cost_{pred}-Cost_{IPOPT}|/Cost_{IPOPT}\times100 $ %. Mean ± std over 3 random seeds.
Two observations: (1) LM barely changes GNN+Constraint, showing its limitation as a standalone correction. (2) For GridDiffuser, guidance modestly improves the selected candidate, reducing Best@K=64 thermal violation from 0.052 to 0.037.
Why LM alone is insufficient. Direct LM correction mainly changes Vm and Va, while its updates to Pg and Qg are much smaller. Branch-flow and thermal residuals depend directly on Vm and Va, whereas Pg and Qg enter power-balance residuals only at generator buses. Consequently,
\gg \|\Delta P_g\|,\ \|\Delta Q_g\|,$$ with a observed difference of $10^3$ times. This limits post-PF improvement because post-PF retains only generator-bus $V_m$ and non-slack $P_g$, while $V_a$, $Q_g$, and slack $P_g$ are recomputed. Thus, an LM update dominated by voltage variables, may reduce pre-PF residuals without improving the final post-PF operating point. In our method, the LM-corrected state is passed through the denoiser again. Since the denoiser learns the coupling among $V_m$, $V_a$, $P_g$, and $Q_g$, voltage-side corrections can induce coordinated changes in the generation variables. Thus, the improvement relies on both the direct LM update and learned cross-variable coupling. To verify this, we backpropagate the residual gradient through the denoiser. The resulting $P_g$ and $Q_g$ updates are comparable to those of $V_m$ and $V_a$ and contribute about 30% of the total residual reduction, confirming meaningful coupling. --- **(3) Unreported objective: cost, optimality gap, and cost–feasibility trade-offs** Please refer to Table 2, where we add the cost gap. We do not observe a clear cost–feasibility trade-off. Lower-violation candidates remain close to the AC-IPOPT cost, with gaps below 0.03% in Table 2. After guidance, the gap decreases from 0.024% to 0.010%. **(4) Generalization Beyond the Training Distribution** The available data do not support such an evaluation, as they do not provide sufficiently distinct grids or operating regimes. This remains an open challenge. PF\$\Delta\$ [2] likewise shows that cross-grid robustness is still difficult for current GNN-based power-flow models. The current setting is still practically relevant. In real operation, the underlying grid usually remains fixed or changes only occasionally, while demand and component availability vary more frequently. However, PGLearn already introduces substantial demand variation through a 40% global scaling range and local perturbations of up to $\pm20$%. **(5) Sensitivity to Sampling and Guidance Hyperparameters** **Table 3: Sensitivity of the selected post-PF solution to hyperparameters on RTE1888.** We vary one hyperparameter at a time while keeping all others at their default values, and report the post-ACPF violation metrics after candidate selection. For efficiency, evaluation uses a subset of the test set with a fixed random seed to remove sampling variability. Default settings are shown in **bold**. | Parameter | Setting | $Q_g$ viol. | Slack $P_g$ viol. | Voltage viol. | Thermal viol. | |---|---:|---:|---:|---:|---:| | Candidates $K$ | 16 | 0.3964 | 0.08114 | 0.003390 | 0.4708 | | | **32** | 0.3760 | 0.03266 | 0.003340 | 0.1007 | | | 64 | 0.3700 | 0.008124 | 0.003000 | 0.08067 | | Diffusion steps | 12 | 0.3803 | 0.04602 | 0.003011 | 0.2313 | | | **18** | 0.3760 | 0.03266 | 0.003340 | 0.1007 | | | 24 | 0.3894 | 0.02729 | 0.003241 | 0.0997 | | Guidance start step | 9 | 0.3955 | 0.02924 | 0.003247 | 0.1560 | | | **12**| 0.3760 | 0.03266 | 0.003340 | 0.1007 | | | 15 | 0.3759 | 0.05239 | 0.003218 | 0.2375 | | $\alpha_{\mathrm{LM}}$ | 0.5 | 0.4083 | 0.06708 | 0.003159 | 0.1767 | | | **1.0** | 0.3760 | 0.03266 | 0.003340 | 0.1007 | | | 2.0 | 0.4042 | 0.003598 | 0.003481 | 0.07747 | | CG iterations | 4 | 0.4107 | 0.03306 | 0.003243 | 0.1049 | | | **8** | 0.3760 | 0.03266 | 0.003340 | 0.1007 | | | 16 | 0.3979 | 0.02937 | 0.003444 | 0.1062 | Some key observations: - Candidates $K$: Larger $K$ gives the clearest gains through a wider candidate pool. - Diffusion steps: Gains saturate beyond a moderate number of steps. - Guidance start step: This is relatively sensitive, middle-to-late guidance works best. - $\alpha_{\mathrm{LM}}$: Stronger correction trades off different violations, and overly large values can degrade performance. - CG iterations: This has the smallest effect because only an approximate LM direction is needed (damping is similarly insensitive except at extreme values). The CG solver can monitor residuals for early stopping, but the tolerance is rarely reached within 8 iterations. **(6) Deployment Feasibility of Best@$K$** Yes. Best@$K$ uses only information available at deployment. For pre-PF selection, we evaluate each candidate’s constraint violations. For post-PF selection, each candidate is passed through a Newton AC power flow, which restores power balance and reveals the remaining violations. We then select the candidate based on these violations and cost. No ground-truth OPF solution is required, and the selection can be completed quickly. **Finally**, we briefly address a few remaining minor points. Best@$K$ is not directly applicable to deterministic baselines, since each produces only one candidate per input. We'd also like to clarify that the current paper already discusses several of limitations the reviewer mentioned in Lines 321-329. --- [1] Canos: A fast and scalable neural ac-opf solver robust to n-1 perturbations. [2] PF\Delta: A benchmark dataset for power flow under load, generation, and topology variations.