Summary
The paper propose SurgVista, a surgical world model to address two challenges: (i) Spatial Interaction Incoherence, where tissues incorrectly responses to instrument contact; (ii) Temporal Fidelity Collapse, where visual quality degrades over long-horizon. The work propose two training strategies: (i) Deformation Consistency Regularization to enforces cross-frame coherence along scene-point trajectories and suppress incoherent instrument-tissue dynamics, and Drift Adaptation Training to mitigates long-horizon drift by perturbing training conditions with online prediction residuals and photometric degradations. This work further propose SurgWorld-Bench, a benchmark with decoupled metrics for instrument-motion accuracy and tissue-response fidelity. Experiment on the propsed SurgWorld-Bench shows improvement from existing methods across different metrics.
Strengths and weaknesses
Strengths The paper identifies two important failure modes and proposed methods to address them accordingly. This is a clear and well-motivated problem. Also, the proposed DAT approach for training is an elegant and novel formulation. Finally, the introduction of a new benchmark with decoupled metrics for instrument-motion accuracy and tissue-response fidelity, is valuable to the community for future work evaluation.
Weaknesses:
The main weakness is around clarity and specifically the link between DCR loss design and deformation consistency. The proposed DCR enforces consistency of latent representations with similar trajectory through InfoNCE, but not the deformation itself. It is unclear how enforcing consistency of latent representations through trajectories can improve deformation consistency. Following, the connection between the supervision signal (keypoint trajectories) and deformable tissues is unclear. DCR uses keypoint trajectories as supervision signal for cross-frame coherence, while the trajectories shows the motion of the rigid instruments, the connection of the trajectories to instrument-tissue dynamics is unclear (i.e how does it links to the deformation correctness). This is a major point.
In addition, the proposed dataset only contains 21 long horizon evaluation clips, which may be insufficient to draw a conclusion of improvement statistically.
Questions
-
Can you quantitatively demonstrate how enforcing consistency of latent representations through trajectories improves deformation consistency ?
-
Can you elaborate on the connection between the keypoint trajectories to instrument-tissue dynamics ?
-
Can you showcase that the stated improved is statistically important. In other term can you show that your model makes consistently better predictions than the SOTA ?
Limitations
Yes the major limitations of the proposed model are discussed.
Paper formatting concerns
N/A
Final justification
The authors have completed a thorough rebuttal with detailed responses that satisfy my comments. Final recommendation is for accept.
Thank you for recognizing the novelty of DAT, and the value of SurgWorld-Bench, as well as for the constructive feedback. Below, we provide a point by point response.
[W1] How DCR improves deformation consistency.
DCR promotes deformation consistency by preserving the correspondence of the same scene point as it moves across frames. Its trajectory records the observed displacement, and DCR keeps the features sampled along this path consistent. The positive pairs therefore represent the same tracked point across frames, rather than points with similar trajectories. Together with flow matching, this reduces correspondence drift and encourages coherent tissue motion over time.
[Q1] Quantitative evidence.
To quantify whether DCR improves deformation consistency, we compare tissue-point trajectories in generated and ground-truth videos. These trajectories provide sparse measurements of tissue displacement over time, so their agreement reflects how closely the generated deformation follows the reference. We quantify this agreement using Tis. AJ and Tissue δavgvis. As shown below, we conduct a controlled ablation by varying only the DCR supervision region. Compared with no DCR, tissue-only supervision improves Tis. AJ and δavgvis by 5.16 and 5.47 points, while full-frame supervision achieves gains of 5.61 and 5.86 points. Instrument-only supervision yields smaller tissue gains of 2.32 and 2.86 points. These results show that DCR improves reference-aligned tissue deformation, with larger gains when tissue trajectories are directly supervised.
[Q2] Connection between trajectories and instrument–tissue dynamics.
Instrument trajectories serve as the action condition, whereas DCR independently samples up to 64 scene-point trajectories from both instrument and tissue regions. These trajectories capture the observed motion of both instruments and tissues, including contact-induced deformation when present. The model learns the instrument–tissue interaction through flow matching, while DCR promotes coherent motion by maintaining feature consistency along the corresponding trajectories.
[W2 and Q3] Long horizon sample size and statistical significance.
For the long-horizon evaluation, we conduct clip-level paired comparisons between SurgVista and the state-of-the-art baseline Wan2.1-Control. We report the mean and standard deviation, along with the mean paired difference and its 95% confidence interval, and assess statistical significance using a two-sided paired t-test. On the original set of 21 clips, SurgVista significantly outperforms Wan2.1-Control across all four metrics.
Note: * indicates p < 0.05 from a two-sided paired t-test.
To further assess robustness, we collected 29 additional clips, expanding the evaluation set from 21 to 50 clips. SurgVista continues to significantly outperform Wan2.1-Control across all four metrics.
Note: * indicates p < 0.05 from a two-sided paired t-test.