Strengths
- Although action-conditioned video generation has been explored in prior work (eg [39]), this paper represents a significant step forward in terms of detailed controllability, with the kinematic visual field encoding complete information about the robot state in image-space, made usable by the hierarchical routing mechanism.
- The paper fills a critical gap in the literature by providing a kinematic articulated surgical action dataset (KASA), evaluating surgical video generation models not just in terms of perceptual quality (CD, FID, etc.) but also in terms of skill-specific evaluation, which is crucial for surgical applications.
- Against relevant baselines, including text-conditioned generation models, raw action-conditioned models, and visual action conditioned models, the proposed method demonstrates significant improvements in both video quality and computational efficiency, with a 26.6% CD improvement over Cosmos-H and a 47.1% latency reduction for the model's "fast" variation.
- The KASA evaluation enables surgical skill-specific evaluation of the generated videos in terms of perceptual quality, highlighting areas where quality could be improved and demonstrating the proposed method's advantage over SOTA methods, especially for knotting and needle puncture.
- The ablation study demonstrates the importance of each component, including the visual kinematic field and the hierarchical routing mechanism, in achieving the reported performance improvements.
- Downstream evaluation demonstrates that synthetic data using the proposed KVLR improves tool segmentation performance.
Weaknesses
Major weaknesses preventing acceptance: None
Minor weaknesses:
Downstream utility is limited to tool segmentation, the only downstream task evaluated in the paper. While this is a reasonable starting point, it does not fully demonstrate the utility of the proposed method for surgical video generation, which is intended to support a wide range of downstream tasks, including surgical skill assessment, training, and decision support. Tool segmentation is by far the easiest downstream task to evaluate and the least likely to benefit from additional data, since realistic synthetic data for tool segmentation could be readily generated using photorealistic rendering of CAD models. Expanding on this aspect, either in experiments or in a more detailed discussion, would strengthen the paper and provide a more comprehensive understanding of the proposed method's impact on surgical video generation.
No comparison to SAW [39], the most methodologically similar approach. Although SAW is not yet publicly available, it would be helpful to include a discussion of how the proposed method compares to SAW in terms of methodology and expected performance. In particular, SAW's use of depth, tip trajectories, and text conditioning is similar to the proposed method, and a discussion of whether these elements can be considered a subset of the proposed method would be useful.
Justification
Although the lack of downstream evaluation beyond tool segmentation is a significant limitation in my view, the paper makes a strong contribution to the field of surgical video generation. The proposed method demonstrates significant improvements over existing methods in terms of video quality and computational efficiency, and the KASA dataset provides a valuable resource for evaluating surgical video generation models. Exhaustive experimental results, including ablation studies and skill-specific evaluation, support the claims made in the paper, and while I would have liked to see a more comprehensive evaluation of downstream utility, the demonstrated benefits for tool segmentation are a strong indication of the generated data's utility. The lack of comparison to SAW is a minor weakness and acceptable given the unavailability of the SAW method, but a discussion of the similarities and differences would have been helpful. Overall, the paper is well-written, and the proposed method is clearly described, with comprehensive experimental results demonstrating its effectiveness.
Thank you for the constructive comments. We address the seven questions in order, followed by the stated concern about obstruction and lower-granularity kinematics.
1. Segmentation-conditioned baseline
As shown in Sec. 4.1 and Table 1, the submission already includes dense-condition baselines (†), including SurgSora† and OpenSora-2.0† with semantic, depth, and flow inputs. As suggested, we add a part-semantic-only OpenSora ablation under the same protocol:
The semantic-only condition uses the same part-semantic representation as the dense-condition baselines, with depth and flow removed. We will add this row to the comparison and its construction to revised Sec. D.1.
2. Kinematic frequency and dimensionality
As described in Sec. 2.2, video and action states are aligned frame by frame at 30 Hz. For each instrument, the 9D action is defined as:
at=[pt,rt,qtsw,qtlg,qtrg]∈R9,
where pt∈R3 is translation, rt∈R3 is axis-angle orientation, and the final three scalars are the shaft-to-wrist and two gripper joint states. Thus each frame contributes nine scalar kinematic values per instrument.
3. Temporal misalignment
For KASA, Differentiable Pose Tracking (DPT) recovers one action state per video frame. For robot logs, timestamps are synchronized and states are interpolated to the video clock. We quantify residual misalignment by offsetting the conditioning sequence by one and two frames:
The ± rows average symmetric shifts. Shifted clips are cropped without circular wrap and evaluated on the common frame subset. These 33/67 ms offsets quantify the effect of synchronization error at 30 Hz.
4. Human-in-the-loop role and sensitivity
As described in Sec. 3, Human-in-the-loop Semantic Annotation (HSA) is used during offline KASA construction. Human annotators correct SAM2 part swaps, leakage, and propagation failures; the refined masks provide part-aware evidence for DPT to recover the 9D action. KVLR is then trained and evaluated using Kinematic-to-Visual Action Fields (KVA-Fields) rendered from the recovered or supplied actions.
We rerun DPT on 89 scenes (118 frames each; 10,502 frame-level pose comparisons) with SAM2-only versus HSA-refined masks, while keeping the instrument computer-aided design (CAD) model, intrinsics, initialization, optimization, and recovery criteria fixed:
The revised Secs. E.3 and E.5 will include the comparison protocol and event definition.
5. Sensitivity to errors in Differentiable Pose Tracking
To isolate how DPT pose errors propagate to generation, we perturb the recovered 9D pose input and regenerate all KVA-Field channels. The perturbed trajectory is used only as the generation input; CD and action-recovery errors remain referenced to the original clean trajectory and real video:
Translation noise is added per axis, rotation perturbations are composed on SO(3), and velocity/acceleration are recomputed. Complementarily, on CRCD, CD changes from 93.60 with real forward kinematics (FK) actions to 98.85 with DPT-reconstructed actions, providing an end-to-end estimate of the effect of empirical DPT errors. The full protocol will be included in Sec. F.8.
6. SAR-RARP versus GraSP
SAR-RARP supplies the in-vivo robot-assisted radical prostatectomy (RARP) videos and action segments used to construct KASA. GraSP contains independently collected cases with different tissue appearance, illumination, viewpoint, acquisition, and annotation. Table 4 evaluates compatible GraSP knotting and needle-puncture segments without GraSP fine-tuning or human correction; it therefore measures cross-dataset scene/domain transfer under familiar action primitives. We will state this subset directly in revised Sec. 4.2 and Table 4.
7. Basis for baseline selection
The baselines cover three conditioning regimes:
As described in Sec. 4.1, all methods use the same operation-disjoint KASA split and reference-frame/text protocol. Table 1 compares these three conditioning regimes, while the parameter-matched architecture ablation in Table 6 isolates raw-action injection, KVA-Field lifting, Tier-1 modality routing, and Tier-2 motion-scale routing.
Additional concern: partial obstruction and less granular kinematics
As described in Sec. E.4, DPT combines part-aware fitting with a keyframe memory pool to maintain or reinitialize tracking when instrument parts are temporarily obstructed. With supplied robot states, the conditioning trajectory remains available throughout visual obstruction. For instruments with fewer physical degrees of freedom, structurally nonexistent joint channels are held constant within the same interface.