- Rating
- 3
- Clarity
- 2
- Confidence
- 2
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This is an insightful and timely paper that offers a principled explanation for a longstanding and practically important asymmetry in cfDNA applications. By identifying (c(v)) as the key parameter governing signal concentration and deriving an architecture-agnostic information bound, the paper provides a clear rationale for when broad genomic coverage should be prioritized over deeper modeling of a small set of regions. I appreciate the way the paper connects its geometric formalization to synthetic experiments with Bayes-optimal references and to a real cfDNA application. Taken together, these elements make the overall story coherent and compelling.
Strengths and weaknesses
Strengths
-
The paper has a strong motivation and theoretical foundation. It addresses the important question of why cfDNA models perform differently in cancer and chronic disease settings by analyzing the distribution of disease signals across genomic windows. By introducing (c(v)), the authors argue that cancer signals are more concentrated, whereas chronic-disease signals are more diffuse, leading to the architectural implication that broader genomic coverage is more important than simply increasing model depth over selected regions.
-
Triangulates evidence across three levels: proxy measurement on 9,432 tissue methylation samples, a controlled synthetic generator with Bayes-optimal ground truth, and a real cfDNA cohort.
Weaknesses
-
Although this is a purely theoretical paper, figures or tables are still needed to improve the readability of the manuscript.
-
Minor but important typographical inconsistencies in key formulas (e.g., F(k) ≤ √(k)/c(v) vs √(k/c(v))) and a likely typo in the definition of ρ(v) could confuse readers.
-
The real cfDNA study lacks detailed disclosure of train/validation/test protocols, covariate control (age, sex, BMI, liver enzymes), batch handling, and hyperparameter selection, making it hard to assess generalization and confounding.
-
Some implementation details for the 1.3M-window model (memory/compute, regularization, feature representation) are under-specified.
-
The tissue-level proxy analysis and the real-cohort evaluation would benefit from additional methodological details, stronger baselines, and sensitivity analyses to address concerns about confounding and generalization. In addition, several notational issues in key formulas should be corrected.
Questions
See weaknesses.
Limitations
Yes.
Paper formatting concerns
The abstract is not written as a single paragraph as required, which may be grounds for desk rejection.
Final justification
Due to several unclear and insufficiently rigorous aspects of the writing, I still maintain my original score.
Thank you for the careful reading and for the specific questions.
W1.
Thank you for pointing out the wording mismatch. We agree the wording overreaches and will narrow it. The revised paper will claim that cancer-style architectures are structurally limited on chronic diseases with diffuse signal, not that all such models fail on all chronic diseases, and the theorem's restrictions to fixed window subsets, per-window marginals and the LAN regime will be emphasised.
W2.
We agree, and will separate the three in Section 3.2: Theorem 1 and Proposition 1 as proved, Conjecture 1 as unproved, and k≳max(d,c(v)) as a design heuristic. We will also state that Proposition 1 gives a necessary and not a sufficient condition on k.
W3.
Thank you for the opportunity to clarify. In the cfDNA validation study we performed a stratified 5-fold cross-validation at the patient level, stratified on fibrosis stage, so no patient contributes to both training and evaluation within a fold. We deliberately did not tune either architecture, to avoid the comparison being confounded by optimisation effort. Architectures were fixed in advance and trained to convergence, with no hyperparameter search, no checkpoint or threshold chosen on validation performance, and no separate validation split. Every number in Table 1 is out of fold.
Feature-selection timing, where the leakage risk would sit, differs by the model. The cfDNA-DMR baseline selects its 631 regions inside each training fold. The tissue-DMR baseline takes its regions from a separate tissue cohort.
The 1.3M-window filter derives from external WGBS data and read-quality expectations, uses no labels and no cohort data, and is identical across all three cohorts. A reference will be added for the source of the windows definition:
Sequencing batches were assigned to be uncorrelated with fibrosis stage at run design, so no post hoc batch correction is involved.
We will add the above points in the revised paper.
Class balance is 171 below F2 and 105 at or above F2. Cohort characteristics:
All patients have biopsy-confirmed MASLD, including the non-fibrotic group. We will add a cohort-description appendix with these characteristics.
Table 1 intervals are computed across fold-level out-of-fold AUCs, so on held-out predictions.
W4.
We obtained two independent cohorts to validate the architectural claim that shallow-and-wide outperforms deep-and-narrow, using the same setup as the primary cohort and with no retuning. The advantage holds in all three datasets.
We separately checked the model trained on the primary cohort on both validation cohorts without retraining. Its advantage over FIB-4 holds in all three datasets.
Cohort characteristics:
W5.
One of the validation cohorts has ELF and Transient Elastography as comparators as well. In that cohort shallow-and-wide's AUC outperformed FIB-4 by 0.14, ELF by 0.11 and Transient Elastography by 0.10.
On modern cfDNA pipelines, to our knowledge all available trained models are trained for cancer. Our two deep-and-narrow baselines were built to occupy the same regime: 631 regions against MethylBERT's 50 to 250 and Pleiades' top 1,000, with a deeper per-region model. The one published pipeline on this exact task is cited in Section 5.3 and also does not exceed FIB-4.
We will expand Table 1 to include the new validation cohorts and add their description to the cohort-description appendix.
The contribution of the paper is the framework and the architectural implication that follows from it, that shallow-and-wide beats deep-and-narrow once the disease signal is diffuse. Although the presented model outperform clinical standard of care, the clinical performance is secondary to it.
Q1.
We performed the stratified cross-validation described under W3. Table 1 intervals are computed across fold-level out-of-fold AUCs, so on held-out predictions. No model-selection decision had access to held-out labels, because no model selection was performed. We will include this in the appropriate section.
Q2.
We report sensitivity at 0.8 specificity, an operating point we consider reasonable for initiating first-line treatment. On the primary cohort, sensitivity was 0.73 for shallow-and-wide against 0.62 for FIB-4.
Q3.
Estimating c(v) from a single cfDNA cohort in one indication would not be reliable, because of signal dilution. The inverse participation ratio is invariant to α in population, but its estimate is a function of the unknown per-sample dilution. Per-window sampling noise does not scale with α, so at the disease fractions present in cfDNA the estimated signal fractions flatten toward uniform. Correcting for this requires assumptions that can be asserted but not verified, about the per-window healthy reference, the noise scale, and the disease fraction.
The measurement that would be meaningful is comparative: the same quantity estimated across several diseases, as in the tissue study of Section 5.1. We do not currently have access to cfDNA cohorts spanning multiple diseases, and to our knowledge no public cfDNA dataset across diseases exists.
This also highlights an assumption we should state more plainly. In the framework c(v) is a property of the disease perturbation in the affected tissue/organ, and cfDNA inherits the regime cfDNA shedding into bloodstream, so tissue is where the quantity is defined and where it is best measured. The tissue-to-cfDNA mapping is not the identity, which we note as the third limitation in Section 6, and we will make the dependence explicit.
Whether cfDNA follows the predicted pattern is nonetheless validated indirectly: the architecture the framework prescribes outperforms deep-and-narrow on three independent cohorts.