acceptodds
Published as a conference paper at NeurIPS 2026

Data-Driven Soft Labeling Scales DNA Read Classification to Whole-Body Cell-Type Deconvolution

Dmytro Rizdvanetskyi, Nathan Roos, Pavlo Lutsik

Abstract

Cell-type deconvolution, the task of estimating the proportions of constituent cell types in a heterogeneous biological sample, is a core problem in computational biology. Methods that rely on epigenetic marks such as DNA methylation typically operate on aggregated methylation estimates, discarding the pattern-level information carried by individual DNA reads. Existing read-level approaches that exploit this information are scarce, and all remain restricted to few-class settings; scaling them further is an open problem because, at scale, non-discriminative reads dominate and hard labels conflict with the many-to-many mapping between methylation patterns and cell types, preventing classifier convergence. To overcome this, we propose data-driven soft labels that estimate the conditional cell-type distribution for each read, and integrate this scheme into *Syto*, a new modular framework for read-level classification-based deconvolution. On a whole-body atlas of 39 human cell types, *Syto* reduces MSE by over SoTA, with gains transferring to an out-of-distribution dataset spanning 16 tissues. *Syto* lays the foundation for modeling increasingly large cell-type panels, with improved applications in biology and healthcare. The proposed soft-labeling scheme is further translatable to any setting with a many-to-many signal-to-label mapping.

Keywords:
Paris, Main Track

Reviews

Among:
Shape:
123456this paper, Bottom 17%
Figure 1. Mean review rating of the reviewed papers at NeurIPS 2026. This paper averages 4.00 over 3 reviews, above 17% of the others.
Reviewer_XrhAOpenReview ↗
Rating
5
Clarity
3
Confidence
5
Originality
3
Quality
3
Significance
3
Read review
Summary

This paper focuses on cell type deconvolution from DNA methylation reads. The goal is to estimate the cell type mixture in heterogeneous samples while preserving information in individual DNA reads instead of pooling methylation information too early. The authors present Syto, a modular pipeline composed of read classification, aggregation, deconvolution, and calibration. An important idea of the paper is to train read classifiers using soft labels that estimate the empirical cell type distribution over reads sharing a methylation signature, instead of trying to assign a hard class to each read. The paper investigates pooling over nearby signatures, several read classifiers, several deconvolution heads, and a simple linear calibration of predicted proportions. The main results are obtained on a 39 cell type WGBS atlas based on simulated pseudobulk mixtures. Tests are also performed on an OOD RRBS tissue dataset by computing a tissue concordance score. The main results are that Syto improves over UXM based on pseudobulk MSE, and that the best settings also work on the OOD tissue data.

Strengths and weaknesses

This is a well executed applied paper tackling a central computational biology problem. The motivation is clear: signal exists at the single read level and hard labeling becomes difficult at the scale of many cell types when reads are ambiguously labeled or are off target. The use of a soft labeling scheme seems like a clean, intuitive and biologically motivated approach that suits the nature of the problem. I also appreciate the modular design of Syto, where the classifier, deconvolver, and calibrator can all be independently improved. Experiments are a bit wider in scope than what is typically done, testing many classifiers, labeling strategies, deconvolvers, and calibrators, and include a 39 cell type atlas. Reported MSE gains compared to UXM are convincing and the OOD RRBS experiment suggests that the method is not only exploiting the specificities of pseudobulk data.

The primary weakness is that the closest quantitative evidence is still from pseudobulk mixtures rather than actual samples where the cell type proportions are known. The OOD experiment is valuable, but tissue concordance is a proxy measure and does not necessarily expose errors within the predicted tissue cell types. Furthermore, the baseline comparison could be broader, as UXM is the main non read level comparator and the broader methylation deconvolution literature has not been evaluated under matched conditions. The performance may be heavily dependent on the chosen genomic regions, and most experiments use 25 DMRs for each cell type. Overall the presentation is quite clear, however the sheer number of experimental conditions is confusing, and the pieces of greatest importance beyond the final strongest configuration are hard to discern. I believe the work is sound and presents valuable results, but the lack of true mixtures and the narrowness of the baseline set put it at the edge of accept.

Questions

Is there any further validation on actual, or partly controlled, mixtures with known cell type proportions for some number of cell types, even if small? My score would increase with a demonstration that these pseudobulk gains reflect accuracy in real mixtures.

Is it possible to make a clearer argument as to why UXM is the primary non read level baseline? I would trust the empirical argument more if there were an expanded comparison or a careful reason as to why other methylation deconvolution methods would not work in this scenario.

How robust are the results to the selection and number of DMRs for each cell type? A brief sensitivity study here would give some indication as to whether the gains are more likely from the read level method or from the design of the reference regions.

It would be good to mention scenarios in which tissue concordance may overestimate OOD performance. One such scenario is if a method places mass on sensible tissue cell types but still fails to get the fine grained proportions correct.

Is it possible for the authors to be very clear as to the sign convention used in the cross entropy formula, and confirm that the loss is minimized in the usual direction? This is probably just a detail of the notation, but as the loss is central, I think it deserves complete clarity.

Limitations

Largely, yes. The authors are reasonably clear about several limitations: dependency on choice of genomic region, the use of only one WGBS atlas, testing against a single OOD RRBS dataset, only a few non read level baselines, suboptimal hyperparameter search, and reliance on pseudobulk mixtures. I also appreciated that they framed tissue concordance as an upper bound type proxy rather than an accurate estimate. The limitations could still be enhanced by discussing deployment risks in a more concrete manner, since the introduction implies that the motivation lies in tumor classification, purity estimation, ctDNA, and clinical applications. A better description of reference atlas representativeness would also be helpful, covering donor variation, disease state, sequencing protocol, and cell types missing from the set. Short coverage of failure cases would be useful, for example when a sample has malignant cells or unobserved cell states. These are not issues that warrant ethics review, but they would aid interpretation of the healthcare positioning.

Paper formatting concerns

None noted.

Final justification

Really strong paper with transparent authors who replied timely to all pressing concerns.

1 comment

We thank the reviewer for a detailed reading and especially for the constructive comments on the limitations section. We are encouraged that the reviewer found our paper to be "well-executed", tackling a "central computational biology problem" with "clear" motivation, that our proposed soft labeling seems "clean, intuitive and biologically motivated", and that our experiments are "a bit wider in scope than what is typically done".

Q1. Validation on real or partly controlled mixtures with known proportions

We agree that real cell mixtures with experimentally validated ground-truth proportions would provide the gold-standard evaluation of Syto. However, to the best of our knowledge, there is no public dataset providing read-level (not Infinium arrays) methylation profiles from in-vivo/in-vitro mixtures with ground truth for whole-body benchmarking.

[de Ridder et al., 2024] profiled 16 non-read-based methods using pseudobulk and in-vitro controlled purified mixtures and showed that the relative ranking of methods in the two contexts was mostly concordant, with the caveat that the level of association was platform-dependent (higher concordance for array platforms with a higher number of CpGs). To the best of our knowledge, no such analysis was done for WGBS data.

Nonetheless, understanding the limitation of pseudobulk, we controlled the generalization of our method beyond pseudobulks in three ways:

(i) We strengthened the pseudobulk experiment by performing splits at the biological sample level (see A.4.1). (ii) The OOD RRBS experiment evaluates performance on real, unmodified samples, with the limitation of relying on a proxy TCS metric. (iii) We have applied Syto and the reference baseline to two pairs of in-house healthy and CRC colon epithelial samples. Both recovered colon epithelium and fibroblasts as the dominant cell types, consistent with biological expectations. We consider this a plausibility check only, as no ground truth is available, and therefore do not include it as a quantitative evaluation.

Q2. Why is UXM the primary non-read-level baseline?

We chose UXM for two reasons. (1) Two independent benchmarks [Giuili et al., 2025; Sun et al., 2024] find UXM among the most accurate methods for WGBS. (2) UXM was designed on the same atlas used to train Syto, so it was considered to be better matched to the marker set than any alternative.

We did not mean to claim other methods would not work under this scenario, only that UXM was a reasonable choice. We expanded our baselines with three additional methods (table below, in bold):

MethodPseudobulk MSE (×10−4\times10^{-4}) ↓OOD TCS ↑
UXM4.2759.70
CelFiE3.2763.93
Houseman CP (no inequality constraint)7.5162.14
EpiDISH8.7858.22
Syto (Dismir, DD Soft Labels with Pooling)0.8866.84

Results using the refined evaluation protocol, see "Refinement of the evaluation protocol" at the end of our response.

We added CelFiE as it is the best method in the DecoNFlow benchmark [Giuili et al., 2025] and is expected to suit UXM atlas markers [Sun et al., 2024]; Houseman CP (no inequality constraint) is the best beta-value method in the same benchmark (reported in DecoNFlow as Houseman_ineq); EpiDISH is best overall in [de Ridder et al., 2024]; CelFiE is a stronger baseline than UXM on both metrics, but Syto remains best on both, by 3.7× in MSE over CelFiE.

Q3. How robust are the results to the DMRs selection? Are the gains more likely from the read level method or from the design of the reference?

Across all experiments, we used the same set of reference regions for the baselines and Syto; therefore, any reported difference between the two is due to the method.

We do not have an experiment that explicitly tests the sensitivity of Syto to the number and type of regions. In our paper, we have indirect evidence that using different types of regions will improve Syto performance.

In Sec. A.3.2, we compare UXM using the original atlas (U25) with UXM run on an alternative atlas of the same size (25 DMRs per cell type), maximizing per-region specificity (through the proxy Gap Specificity Score or GSS). As shown in A.5.2, using the alternative atlas improves UXM by +8.36 on TCS and even approaches the results of UXM run on the larger U250 atlas. Although we did not retrain Syto on the alternative atlas, we expect Syto to also benefit from better region selection. This expectation is supported by the observation that the Spearman correlation between the proxy GSS and per-cell-type deconvolution R2R^2 was 0.61 for Syto w/ hard labels, 0.62 for Syto w/ DD soft labels, and 0.58 for UXM. These correlations indicate that both Syto and UXM obtain better results on more specific regions. Moreover, on the three cell types with the least specific regions, per-cell-type R2R^2 was 0.49 / 0.76 / 0.84 for UXM versus 0.83 / 0.88 / 0.95 for Syto w/ hard labels and 0.84 / 0.92 / 0.95 for Syto w/ DD soft labels, showing that Syto performance degrades much less on genomic regions with low specificity, and that soft labeling improves performance on low-specificity regions.

As for the number of regions: in Fig. 4 and also in Sec. A.5.2, we show that using 10x more regions for UXM greatly improves the TCS metric. We designed the framework to take advantage of additional data; therefore, Syto should be able to leverage the higher number of regions, especially through the soft labeling scheme that can differentiate higher and lower confidence regions.

Q4. Can we mention where TSC may overestimate OOD performance?

The scenario with mass placed on plausible cell types while the fine-grained proportions are wrong is indeed one of the failure modes of TCS. In fact, it can occur in two flavours: (1) when a cell type is overpredicted in a specific tissue (it inflates individual TCS per tissue); (2) when the model predicts a constantly high proportion for a cell-type that is common across most of the tissues (inflates TCS across all tissues).

To mitigate (1), we construct the expected set of cell types per tissue by keeping only. those with a proportion in Tabula Sapiens higher than the 1% threshold: this trades off having lower absolute TCS in exchange for fewer spurious types. For (2), we verified that the three cell types expected in most tissues (15 out of 16) receive comparable mass from Syto and the baselines, so it does not explain the difference between them.

A mild variant of the reviewer's scenario seems to occur in our results. In the Ovary tissue, where methods diverge most, Tabula Sapiens reports 74% ovarian epithelium, yet every method, ours included, recovers 0–4%. TCS nonetheless awards 56-69 to Syto (DD Soft Labels, Dismir) and 17-20 to UXM, earned on the second most abundant cell type (16% Smooth Muscle in the reference, 10% in UXM but 40-52% in Syto). It is worth mentioning that Syto results correlate highly with UXM run on the 10x larger U250 atlas, as well as with UXM run on an alternative atlas of the same size maximizing per-region specificity (through the proxy GSS, see Q3), recovering 46-57% of Smooth Muscle. This leads us to think that the reference may be biased against Smooth Muscle in Ovary tissue.

We will add the full per-tissue failure-mode analysis to the appendix and state in the main. text that TCS supports relative comparison only, cannot detect within-tissue proportion errors, and must be screened for these failure modes before being acted upon.

Q5. Sign convention in the cross-entropy formula

We thank the reviewer for spotting this typo. Indeed, we intended CE loss to be minimized in conventional direction:

CE(ui,ti):=−∑cti,clog⁡ui,c.\mathrm{CE}(\mathbf{u_i}, \mathbf{t_i}) := -\sum_{c} t_{i,c}\log u_{i,c}.

We will correct it in the camera-ready version of the paper.

Answers to remarks in the limitations section

We are grateful for the specific suggestions and propose the next plan:

  1. We will describe concrete deployment risks given the clinical framing.
  2. The requested information about reference-atlas representativeness covering donor variation, disease state, sequencing protocol, and absent cell types is available in great detail in GEO at accession number GSE186458. We will reflect the important points in the limitations.
  3. We will list explicit failure cases for samples containing malignant cells or unobserved cell states in the limitations.

Refinement of the evaluation protocol

We want to inform about two post-submission refinements, applied identically to every method. It does not change the main conclusions; in particular, Syto remains the strongest method by a solid margin.

(a) Removing an leakage in the UXM reference that favoured UXM baseline. In the reported UXM baseline results, we used the pre-computed per-DMR unmethylated-read fractions from the original paper by [Loyfer et Al 2023]. Those values were computed using the entire dataset (including the samples used as the test split in our experiment). Therefore, information from the test split leaked into the reference used by UXM to estimate proportions. No such leak exists in Syto, because Syto doesn't use this information. We noted UXM's "unfair advantage" in the submitted paper, but on reflection this is a serious leak: we will report UXM's results with parameters computed on the train split only.

(b) Read inclusion refinement. The tool for recovering mapped reads from raw .pat files kept only the reads lying strictly within the selected genomic regions, discarding reads overlapping region boundaries. That was equally detrimental for UXM and Syto for the pseudobulk experiment, but only detrimental for Syto in the OOD experiment, because there we used the original UXM implementation that bypasses the read recovery and runs directly on raw .pat files. We intend to present the results obtained on the full set of reads in the final version of the paper.

Reviewer_3TdVOpenReview ↗
Rating
5
Clarity
3
Confidence
5
Originality
3
Quality
3
Significance
3
Read review
Summary

This paper proposes Syto, a modular framework for read-level DNA methylation-based cell-type deconvolution. The key idea is to avoid forcing each read into a single hard cell-type label, since the same methylation pattern in a genomic region can be shared by multiple cell types. The authors introduce data-driven soft labels that estimate the empirical cell-type distribution associated with each read signature, with additional pooling to handle low coverage. These labels are used to train read-level classifiers, whose predictions are aggregated and passed to deconvolution and calibration modules. Experiments show improved performance over UXM and support the usefulness of the soft-labeling scheme.

Strengths and weaknesses

The paper studies an important problem in methylome-based deconvolution. The motivation is convincing: read-level methylation patterns contain useful information, but hard read labels become problematic when scaling to many cell types. The proposed data-driven soft labels are simple, biologically plausible, and appear to directly address this issue.

The main weakness is the lack of real samples with known cell-type proportions. The primary evaluation is based on pseudobulks, while the OOD RRBS experiment uses a tissue concordance score rather than true deconvolution error. This is understandable given data limitations, but it still limits how strongly one can interpret the practical accuracy of the method.

A second concern is that the comparison to non-read-level deconvolution methods is relatively narrow. UXM is an important baseline, but a broader benchmark would better position the method. I also think the sensitivity to region selection, pooling parameters, and reference quality should be analyzed more clearly, since these choices seem central to the construction of the soft labels.

Questions
  1. Can the authors provide more analysis on the sensitivity of Syto to the soft-label pooling parameters, such as the minimum read depth and distance threshold? This would help assess how robust the method is.

  2. How dependent are the results on the selected genomic regions? Since region choice is known to strongly affect methylation deconvolution, an analysis using different numbers or types of regions would strengthen the paper.

  3. Can the authors compare against additional non-read-level deconvolution methods, at least in the pseudobulk setting? This would make the performance claims easier to interpret.

  4. The OOD RRBS evaluation uses tissue concordance rather than true proportions. Can the authors discuss cases where TCS may be misleading, for example when expected cell types are broad or when unexpected rare cell types are biologically present?

  5. Can the authors clarify how well the method would scale to malignant cell types or disease states, where the reference may be incomplete and methylation patterns may be more heterogeneous?

Limitations

Yes.

Paper formatting concerns

None.

Final justification

The authors have well addressed my concerns. I retain my suggestion of accept.

1 comment

We thank the reviewer for their careful reading and for asking questions targeting important parts of the paper. We are encouraged that the reviewer found that our paper tackles "an important problem in methylome-based deconvolution" with "convincing" motivation, and that our proposed data-driven soft labels are "simple, biologically plausible, and appear to directly address this issue".

Q1. Sensitivity to the soft-label pooling parameters

Both parameters were chosen using dataset-driven heuristics:

  • Distance threshold (=0.41): More than 80% of reads in our training data contain 4–7 CpGs. A Jaccard distance threshold of 0.41 allows reads in this range to differ by at most one CpG, reflecting the high local correlation of CpG methylation. Differences in two or more CpGs are more likely to represent a biological change. This threshold choice groups 4-CpG reads with methylation levels of 0 and 0.25, as well as 0.75 and 1.0, consistent with the UXM.
  • Minimum read depth (=30): We argue that the required read depth should depend on the number of modeled classes while still providing sufficient support. Setting the threshold too high may unnecessarily discard informative variation. We therefore used 30 reads, slightly below the number of cell types.

Pooling was intended as an extension, which is why we feature a version without pooling. We understand and share the reviewer's interest in exploring the sensitivity to pooling parameters. Testing it was left in our roadmap for future work, but if time permits, we will share some initial results during the discussion period.

Q2. Dependence on the selected genomic regions

We do not have an experiment that explicitly tests the sensitivity of Syto to the number and type of regions. In our paper, we have indirect evidence that using different types of regions will improve Syto performance.

In Sec. A.3.2, we compare UXM using the original atlas (U25) with UXM run on an alternative atlas of the same size (25 DMRs per cell type), maximizing per-region specificity (through the proxy Gap Specificity Score or GSS). As shown in A.5.2, using the alternative atlas improves UXM by +8.36 on TCS and even approaches the results of UXM run on the larger U250 atlas. Although we did not retrain Syto on the alternative atlas, we expect Syto to also benefit from better region selection. This expectation is supported by the observation that the Spearman correlation between the proxy GSS and per-cell-type deconvolution R2R^2 was 0.61 for Syto w/ hard labels, 0.62 for Syto w/ DD soft labels, and 0.58 for UXM. These correlations indicate that both Syto and UXM obtain better results on more specific regions. Moreover, on the three cell types with the least specific regions, per-cell-type R2R^2 was 0.49 / 0.76 / 0.84 for UXM versus 0.83 / 0.88 / 0.95 for Syto w/ hard labels and 0.84 / 0.92 / 0.95 for Syto w/ DD soft labels, showing that Syto performance degrades much less on genomic regions with low specificity, and that soft labeling improves performance on low-specificity regions.

As for the number of regions: in Fig. 4 and also in Sec. A.5.2, we show that using 10x more regions for UXM greatly improves the TCS metric. Although we do not have the experimental evidence for Syto, we designed the framework to take advantage of additional data; therefore, Syto should be able to leverage the higher number of regions, especially through the soft labeling scheme that can differentiate higher- and lower-confidence regions.

Q3. Additional non-read-level baselines

To answer your question, we added three new baselines: CelFiE, Houseman CP (no inequality constraint), and EpiDISH. They were trained and evaluated using the same set of genomic regions as UXM U25 and Syto (namely the U25 atlas from [Loyfer et al., 2023]).

MethodPseudobulk MSE (×10−4\times10^{-4}) ↓OOD TCS ↑
UXM4.2759.70
CelFiE3.2763.93
Houseman CP (no inequality constraint)7.5162.14
EpiDISH8.7858.22
Syto (Dismir, DD Soft Labels with Pooling)0.8866.84

Results using the refined evaluation protocol, see "Refinement of the evaluation protocol" at the end of our response.

We added CelFiE as it is the best method in the DecoNFlow benchmark [Giuili et al., 2025] and is expected to suit UXM atlas markers [Sun et al., 2024]; Houseman CP (no inequality constraint) is the best beta-value method in the same benchmark (reported in DecoNFlow as Houseman_ineq); EpiDISH is best overall in [de Ridder et al., 2024]; CelFiE is a stronger baseline than UXM on both metrics, but Syto remains best on both, by 3.7× in MSE over CelFiE.

Q4. Can the authors discuss cases where TCS may be misleading?

TCS indeed can overestimate but also underestimate OOD performance; without inspecting the predicted proportions themselves, one cannot say how much credibility a TCS score deserves. We screened for three failure modes:

  1. Spurious expected cell type — a cell type with negligible proportion in the tissue is listed as expected, rewarding a method that overpredicts it.
  2. Missing expected cell type — an abundant cell type may be under-detected by the scRNA-seq behind Tabula Sapiens, so a method that correctly recovers it is penalised.
  3. Ubiquitous cell type — a cell type is truly present in a majority of tissues, rewarding any method biased toward overpredicting it.

To mitigate (1), we construct the expected set of cell types per tissue by keeping only. those with a proportion in Tabula Sapiens higher than the 1% threshold: this trades off having lower absolute TCS in exchange for fewer spurious types. (2) cannot be fully controlled, though a moderately abundant type rarely falls below 1%: adipocytes are under-detected in Tabula Sapiens fat tissue (only adipose mesenchymal stem cells, at 4%) yet still enter the expected set. For (3), we checked the three most expected cell types (expected in 15/16 tissues); the recovered fractions were comparable across methods and not far from the reference (see the table below), meaning that the difference in TCS is not explained by this failure mode.

Cell typeUXM U25UXM U250CelfieSyto (Dismir, DD Soft Labels)Tabula Sapiens
Endothel0.1460.1440.1710.129–0.1540.107
Blood-B0.0370.0320.0340.038–0.0420.056
Blood-T0.0500.0480.0540.053–0.0580.120

We will add the full per-tissue failure-mode analysis to the appendix and state in the main. text that TCS supports relative comparison only, cannot detect within-tissue proportion errors, and must be screened for these failure modes before being acted upon.

Q5. Clarify methods scaling to the incomplete reference and heterogeneous methylation patterns

Like all reference-based methods, Syto is currently limited to cell types present in its reference; given an incomplete reference, it has no mechanism to account for unknown cell types and should not be expected to give reliable proportions. We state this plainly and regard an explicit unknown-fraction component as one of the important items of future work.

For now, we can mitigate this by mapping the target cell type onto its closest reference counterpart: the MethylBERT authors used the prostate-epithelium fraction in lymph node samples as a proxy for tumour purity, on the grounds that prostate-cancer metastases retain a methylation profile concordant with normal prostate epithelium. As for how well our method will scale to more heterogeneous patterns, the current atlas already involves several cell types where on-target signal is more heterogeneous and where there is more cross-contamination with other cell types. For example, in Colon-Fibro-specific regions, the average methylation level for Colon Fibro is 31%, while Bone Osteoblasts, Dermal-Fibro and Blood-B show an average methylation of 45%, 57% and 58% respectively - meaning that those cell types might appear the same from the average methylation level perspective. However, the R2R^2 scores for these cell types obtained in the pseudobulk experiment were 48.7%, 93.8%, 75.7%, 95.0% for UXM and 84.2%, 99.7%, 97.45%, 96.3% for Syto (DD Soft Labels, Dismir, SWN, uncalibrated results), suggesting that Syto is more robust to the presence of heterogeneous regions. Similar, albeit not as pronounced, effects were observed in Smooth-Muscle regions and Endothel regions.

Refinement of the evaluation protocol

We want to inform you about two post-submission refinements, applied identically to every method. It does not change the main conclusions; in particular, Syto remains the strongest method by a solid margin.

(a) Removing an leakage in the UXM reference that favoured UXM baseline. In the reported UXM baseline results, we used the pre-computed per-DMR unmethylated-read fractions from the original paper by [Loyfer et Al 2023]. Those values were computed using the entire dataset (including the samples used as the test split in our experiment). Therefore, information from the test split leaked into the reference used by UXM to estimate proportions. No such leak exists in Syto, because Syto doesn't use this information. We noted UXM's "unfair advantage" in the submitted paper, but on reflection this is a serious leak: we will report UXM's results with parameters computed on the train split only.

(b) Read inclusion refinement. The tool for recovering mapped reads from raw .pat files kept only the reads lying strictly within the selected genomic regions, discarding reads overlapping region boundaries. That was equally detrimental for UXM and Syto for the pseudobulk experiment, but only detrimental for Syto in the OOD experiment, because there we used the original UXM implementation that bypasses the read recovery and runs directly on raw .pat files. We intend to present the results obtained on the full set of reads in the final version of the paper.

Reviewer_JYygOpenReview ↗
Rating
2
Clarity
3
Confidence
4
Originality
3
Quality
3
Significance
3
Read review
Summary

This paper studies DNA methylation-based cell-type deconvolution from read-level methylation patterns. It proposes Syto, a modular pipeline that separates read-level classification, genomic-region aggregation, deconvolution, and calibration. The central idea is to replace hard labels with data-driven soft labels that estimate the empirical conditional distribution over cell types for each methylation signature, addressing the many-to-many relationship between read patterns and cell types.

Strengths and weaknesses

Strengths : The data-driven soft-labeling motivation is biologically plausible: the same or similar methylation signatures can occur in multiple cell types, making one-hot labels noisy at whole-body scale.

Weaknesses:

  1. The core soft-label method should be checked carefully in Section 3.2.1, Section 3.2.2, Algorithm 1, and Equation 5. These are the locations where the label-smoothing target, class-reweighting description, and cross-entropy notation need to be made consistent with the implementation.
  2. Table1 is hard to interpret. It mixes external baselines, author-extended versions of existing classifiers, labeling schemes, deconvolvers, and calibration choices, making it unclear which rows are external baselines, Syto variants, or Syto ablations.
  3. Baseline coverage is somewhat narrow: the main comparison is against UXM, a 2023 Loyfer-atlas-based method and add one recent methylation deconvolution benchmark methods.
Questions

NA

Limitations

Yes

Paper formatting concerns

NA

1 comment

We thank the reviewer for three concrete and actionable criticisms. We address the three weaknesses mentioned below and believe they are now resolved.

W1. Consistency across Sec. 3.2.1, Sec. 3.2.2, Alg. 1 and Eq. 5

The reviewer is right on both counts: the notation is sometimes inconsistent, and Eq. 5 as printed does not match our implementation.

(i) Notation. Labels and losses are defined for a read rir_i with omics signature sis_i and class ci∈C:={1,…,C}c_i \in \mathcal{C} := \{1,\dots,C\}, where CC is the number of cell types; cic_i is the hard label.

Sec. 3.2.1 introduces the hard label with background yi∈C∪{⊥}y_i \in \mathcal{C} \cup \{\bot\}: yi=ciy_i = c_i if rir_i is on-target (lies in a GR group specific to cic_i), and yi=⊥y_i = \bot otherwise. In the code, cell types are 0-indexed and therefore ⊥\bot maps to index CC; this implementation detail is deliberately omitted from the main text. Eq. 3 then defines the label-smoothed target yˉi\bar{\mathbf{y}}_i, of length C+1C+1, as the convex combination of the uniform distribution over C+1C+1 classes with weight ϵ\epsilon and the one-hot encoding of yiy_i with weight 1−ϵ1-\epsilon.

Sec. 3.2.2 uses the same symbol qi\mathbf{q}_i with and without pooling, which can be confusing. We will write qi\mathbf{q}_i for the unpooled soft label (Eq. 4) and qi(pooled)\mathbf{q}_i^{(\mathrm{pooled})} for the pooled one (Alg. 1); both are length-CC vectors in ΔC−1\Delta^{C-1}.

Class reweighting applies to both. To make this unambiguous we will rewrite Eq. 4 as qi,c:=ni,c/∑c′=1Cni,c′q_{i,c} := n_{i,c} / \sum_{c'=1}^{C} n_{i,c'} for all c∈Cc \in \mathcal{C}, where ni,cn_{i,c} is the number of reads with signature sis_i and class cc — the symbol already used in Alg. 1. Lines 199–200 then clearly refer to ni,⋅\mathbf{n}_{i,\cdot}, with no collision with the Alg. 1 variables n~i\tilde{\mathbf{n}}_i (pooled per-class counts) and n^i\hat{\mathbf{n}}_i (pooled and class-reweighted per-class counts).

(ii) Corrected loss. Eq. 5 as printed treats on-target and off-target reads differently; the implementation does not, and the implementation produced the reported results. Hence, we will replace lines 208–213 with:

We use a confidence-weighted CE loss ("entropy-weighted" in the submission; "confidence-weighted" is the accurate term). For a read rir_i with soft label ti\mathbf{t}_i of length CC and predicted class probabilities ui\mathbf{u}_i, the weight is (max⁡(ti)−C−1)/(1−C−1)\big(\max(\mathbf{t}_i) - C^{-1}\big) / \big(1 - C^{-1}\big) and the loss is LCW(ui,ti):=(max⁡(ti)−C−11−C−1)CE(ui,ti),\mathcal{L}^{\mathrm{CW}}(\mathbf{u}_i, \mathbf{t}_i) := \big(\frac{\max(\mathbf{t}_i) - C^{-1}}{1 - C^{-1}}\big)\mathrm{CE}(\mathbf{u}_i, \mathbf{t}_i),

where CE(ui,ti):=−∑cti,clog⁡ui,c\mathrm{CE}(\mathbf{u_i}, \mathbf{t_i}):= -\sum_{c} t_{i,c} \log u_{i,c} is the standard cross-entropy.

We use generic ti\mathbf{t}_i because the loss is applied to both soft labels with and without pooling. The weight is 0 for a maximally uncertain label and 1 for a one-hot label.

W2. Table 1 is hard to interpret

We agree. In the submission, the only external baseline is UXM; the first block summarises Syto ablations without calibration (best deconvolver by test MSE for each classifier and labelling/prior pair) and the second summarises Syto variants with calibration (best deconvolver and calibrator). This is stated in the caption but is not visually apparent.

Table 1 will be restructured into three explicitly headed sections — (1) Syto ablations, no calibration; (2) Syto variants, with calibration; (3) external baselines (UXM + new baselines (see Q3)), so external baselines, author-extended classifiers and Syto ablations are distinguishable. Overall, we will simplify and restructure the table and move the details that are not essential to the appendix.

W3. Baseline coverage

To answer your question, we added three new baselines: CelFiE, Houseman CP (no inequality constraint), and EpiDISH. They were trained and evaluated using the same set of genomic regions as UXM U25 and Syto (namely the U25 atlas from [Loyfer et al., 2023]).

MethodPseudobulk MSE (×10−4\times10^{-4}) ↓OOD TCS ↑
UXM4.2759.70
CelFiE3.2763.93
Houseman CP (no inequality constraint)7.5162.14
EpiDISH8.7858.22
Syto (Dismir, DD Soft Labels with Pooling)0.8866.84

Results using the refined evaluation protocol, see "Refinement of the evaluation protocol" at the end of our response.

We added CelFiE as it is the best method in the DecoNFlow benchmark [Giuili et al., 2025] and is expected to suit UXM atlas markers [Sun et al., 2024]; Houseman CP (no inequality constraint) is the best beta-value method in the same benchmark (reported in DecoNFlow as Houseman_ineq); EpiDISH is best overall in [de Ridder et al., 2024]; CelFiE is a stronger baseline than UXM on both metrics, but Syto remains best on both, by 3.7× in MSE over CelFiE.

Refinement of the evaluation protocol

We want to inform you about two post-submission refinements, applied identically to every method. It does not change the main conclusions; in particular, Syto remains the strongest method by a solid margin.

(a) Removing an leakage in the UXM reference that favoured UXM baseline. In the reported UXM baseline results, we used the precomputed per-DMR unmethylated read fractions from the original paper by [Loyfer et al., 2023]. Those values were computed using the entire dataset (including the samples used as the test split in our experiment). Therefore, information from the test split leaked into the reference used by UXM to estimate proportions. No such leak exists in Syto, because Syto doesn't use this information. We noted UXM's "unfair advantage" in the submited paper, but on reflection this is a serious leak: we will report UXM's results with parameters computed on the train split only.

(b) Read inclusion refinement. The tool for recovering mapped reads from raw .pat files kept only the reads lying strictly within the selected genomic regions, discarding reads overlapping region boundaries. That was equally detrimental for UXM and Syto for the pseudobulk experiment, but only detrimental for Syto in the OOD experiment, because there we used the original UXM implementation that bypasses the read recovery and runs directly on raw .pat files. We intend to present the results obtained on the full set of reads in the final version of the paper.

Comments on the paper

1 comment
Meta-review

The paper studies DNA methylation-based cell-type deconvolution from read-level methylation patterns. Its main claim is that data-driven soft labels can better represent the many-to-many relationship between methylation signatures and cell types. The results show improved performance over UXM on pseudobulk mixtures and encouraging results on an OOD RRBS tissue dataset. The main strengths are the clear biological motivation, the simple and intuitive soft-labeling idea, and the modular Syto pipeline. The pipeline separates read classification, aggregation, deconvolution, and calibration, making the system flexible and extensible. The experiments are also reasonably broad, covering multiple classifiers, deconvolution heads, labeling strategies, and a 39-cell-type WGBS atlas. The main concerns are that most quantitative evidence comes from pseudobulk mixtures rather than real samples with known cell-type proportions. The OOD evaluation also relies on tissue concordance rather than true deconvolution error. In addition, the comparison to broader methylation deconvolution methods is somewhat limited. There are also clarity issues such as around the loss formulation, Table 1, and the many experimental variants. Still, two reviewers recommend acceptance, including one with very high confidence. Both view the method as sound, useful, and well motivated despite the evaluation limitations. I therefore recommend acceptance, with encouragement for the authors to clarify the soft-label objective, variants and baselines, and more carefully discuss the limits of pseudobulk and tissue-concordance evaluation.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Related papers

Loading the map…

Discussion (0)

Sign in to comment.