Multimodal molecular representation learning plays a crucial role in drug discovery and molecular property prediction. Existing cross-modal alignment approaches primarily reinforce redundant information across modalities, often neglecting complementary synergistic signals critical for downstream tasks. To address this limitation, we propose MSC-Mol, a modality-synergy contrastive pre-training framework that encodes SMILES sequences, 2D molecular graphs, and 3D conformations into a unified fused representation, optimized via contrastive learning over augmented views. By introducing challenging negatives, including single-modality replacements and modality recombinations, MSC-Mol encourages the model to capture fine-grained cross-modal correspondences beyond dominant-modality shortcuts. We further design probe tasks-long-range pharmacophore prediction, molecular property regression, and functional-group combination classification-to validate that MSC-Mol preserves both modality-specific and synergistic information. Extensive experiments demonstrate that MSC-Mol consistently outperforms existing 2D, 3D, and multimodal pre-training methods on molecular property prediction, drug–target interaction(DTI) tasks, and probe evaluations, highlighting its effectiveness in capturing cross-modal synergy and long-range molecular dependencies. The code is available at https://anonymous.4open.science/r/MSC-Mol-169D.

Keywords:
Sydney, Main Track

Reviews

Among:
Shape:
123456this paper, Bottom 49%
Figure 1. Mean review rating of the reviewed papers at NeurIPS 2026. This paper averages 4.33 over 3 reviews, above 49% of the others.
Reviewer_KVYxOpenReview ↗
Rating
4
Clarity
3
Confidence
4
Originality
3
Quality
3
Significance
3
Read review
Summary

The authors point out that existing cross-modal alignment methods often focus on learning redundant information across modalities, failing to fully capture the synergistic information among SMILES strings, 2D molecular graphs, and 3D conformations. To address this, the paper proposes MSC-Mol, which employs pre-training strategies including a unified multimodal fusion encoder, modality masking, single-modality replacement, modality-recombined hard negatives, and reconstruction tasks. The authors further design several "probe tasks" and evaluate the model's performance on molecular property prediction and drug-target interaction (DTI) tasks.

Strengths and weaknesses

Strengths The motivation is clear. Rather than simply asserting that "multimodality is useful," the authors highlight that cross-modal alignment may overemphasize shared information while overlooking synergistic signals that require joint multimodal reasoning—an insightful perspective. The methodological design is comprehensive; specifically, the use of modality replacement and modality-recombined hard negatives forces the model to verify genuine consistency across modalities, preventing reliance on "shortcuts" provided by a single dominant modality. Regarding experiments, the paper reports results on MoleculeNet and DTI datasets while also designing LR-P3, molecular property probes, and functional-group combination probes to analyze cross-modal synergy, resulting in a well-rounded experimental pipeline.

Weaknesses The main limitation is that the methodological innovation remains somewhat incremental. Techniques such as multimodal fusion, masked reconstruction, contrastive learning, and hard negative construction are established concepts; the paper primarily integrates these components into a multimodal pre-training framework for molecules. The analyses concerning partial information decomposition and mutual information serve more as a justification for the motivation rather than a rigorous proof that MSC-Mol has indeed learned synergistic information. Additionally, while the probe tasks are useful, they are largely diagnostic tasks constructed by the authors; the relationship between these probes and real-world drug discovery tasks requires further clarification. Finally, aspects such as 3D conformer quality, stability when the 3D modality is missing, pre-training costs, and robustness against noise in different modalities are not sufficiently discussed.

Questions
  1. What are the core differences between MSC-Mol's hard negative construction and existing techniques like modality corruption or tuple contrastive learning in multimodal contrastive learning?
  2. To what extent do the probe tasks adequately represent the cross-modal synergy found in real-world drug discovery?
  3. Does the method remain robust in scenarios involving high noise in 3D conformers, missing 3D modalities, or imbalanced quality across modalities?
  4. While current theoretical analysis suggests that alignment might bias towards redundant information, is there more direct evidence demonstrating that MSC-Mol learns synergistic information, rather than simply achieving performance gains through stronger data augmentation or more challenging negative samples?
  5. How do the pre-training and inference costs compare to existing multimodal molecular pre-training methods?
Limitations

Yes

Paper formatting concerns

NA

Final justification

The author has provided new evidence that strengthens the argument, and the article demonstrates sufficient originality; my final decision is to accept it.

1 comment

We sincerely thank Reviewer KVYx for the thoughtful review. Your insightful questions have been very helpful in improving the clarity and rigor.


Response to Q1: Difference from TupleInfoNCE and Generic Modality Corruption

Difference from TupleInfoNCE and modality corruption. TupleInfoNCE primarily enforces tuple-level correspondence between modalities, whereas MSC-Mol is further trained to be sensitive to which molecular modality becomes inconsistent, whether SMILES, 2D topology, and 3D geometry remain chemically compatible, and whether fine-grained information can be inferred across modalities.

To achieve this, MSC-Mol combines two designs. First, single-modality replacement and modality-wise recombination selectively break cross-modal consistency while keeping each modality individually valid, forcing the model to locate local inconsistencies and judge global molecular coherence. Second, non-overlapping masking removes different molecular information from different modalities and requires SMILES token prediction, 2D atom-attribute prediction, and 3D coordinate denoising. Since the missing content in one modality remains visible in the others, the model must use cross-modal evidence for reconstruction rather than relying only on within-modality patterns.

Therefore, our design goes beyond tuple-level matching: the negative construction learns whether the modalities are compatible, while the reconstruction objective encourages fine-grained information transfer among them.


Response to Q2: Scope and Real-World Relevance of the Probe Tasks

Scope of the probe tasks. The probe tasks are intended as controlled diagnostics of cross-modal interaction, rather than complete surrogates for real-world drug discovery. Since our self-supervised framework has no fixed downstream target YY, explicitly isolating and optimizing the PID synergy term SS is difficult. The probes therefore provide operational evidence that the learned representation can combine complementary information from multiple modalities, rather than a direct quantitative estimate of SS.

Our framework provides a foundation for such extensions, while the current probes should be interpreted specifically as evidence of structural cross-modal interaction rather than a complete representation of biological, cellular, or clinical synergy in real-world drug discovery.


Response to Q3: Robustness to Missing and Imperfect 3D Modalities

We agree that robustness to imperfect 3D information is important. Our 3D encoder constructs spatial neighborhoods using a radius graph, where two atoms are connected only when their interatomic distance falls within a predefined cutoff. Consequently, coordinate noise affects not only the continuous distance features but potentially also the discrete neighborhood structure.

This makes a simple coordinate-noise evaluation difficult to interpret. Small perturbations may leave most interatomic distances and radius-based edges unchanged and thus produce little observable effect, whereas perturbations that move atoms across the cutoff can abruptly add or remove edges. Larger perturbations may further generate chemically implausible conformers. Therefore, the result would be highly sensitive to an arbitrarily selected noise scale rather than providing a well-defined measure of realistic 3D uncertainty.

For this reason, we focus on the more clearly defined missing-modality setting, which directly evaluates whether MSC-Mol remains effective when an entire structural modality is unavailable. We will clarify that robustness to inaccurate conformers is not fully covered by the current evaluation and remains an important direction for future work.

We evaluated MSC-Mol on six MoleculeNet datasets under full- and missing-modality settings. Compared with the variant without modality-masked positives, MSC-Mol exhibits smaller cumulative degradation (5.5 vs. 8.1 ROC-AUC points), demonstrating greater stability under unavailable modalities.

Available ModalitiesMethodBBBPTox21ToxCastSIDERClinToxBACEAvg.
1D+2D+3DMSC-Mol w/o modality-masked positives72.8±1.374.5±0.668.1±0.364.3±0.897.6±2.284.0±1.576.88
1D+2D+3DMSC-Mol73.9±0.775.1±1.668.5±0.265.1±0.598.7±0.884.4±0.777.62
1D+2DMSC-Mol w/o modality-masked positives71.8±1.571.4±0.563.3±0.461.7±0.995.4±1.781.7±1.474.22
1D+2DMSC-Mol72.6±0.773.0±0.465.8±0.662.7±1.298.0±1.882.2±1.875.72
1D+3DMSC-Mol w/o modality-masked positives71.5±0.672.2±0.863.2±0.660.1±0.394.1±2.083.0±1.374.02
1D+3DMSC-Mol72.6±1.673.1±0.963.3±0.362.3±0.596.7±3.382.8±0.975.13
2D+3DMSC-Mol w/o modality-masked positives71.7±0.873.1±1.164.6±0.461.4±0.593.3±3.782.2±0.674.38
2D+3DMSC-Mol73.2±1.175.2±0.467.5±0.864.3±0.995.8±2.783.4±1.976.57

Response to Q4: Evidence Beyond Stronger Augmentations and Harder Negatives

We agree that stronger augmentations and harder negatives are possible alternative explanations. Our current evidence therefore relies not only on overall downstream gains, but also on controlled objective variants and synergy-sensitive probes.

First, the compared variants progressively introduce fused contrast, unimodal-to-fused alignment, modality perturbation, and reconstruction under the same overall architecture, allowing us to examine which type of training signal contributes to the improvement. We further observe that MSC-Mol reduces the strong 3D-modality shortcut and produces a more balanced use of SMILES, 2D, and 3D information.

Second, we will report the Easy, Medium, and Hard LR-P3 settings separately. The Medium setting is particularly informative because each negative satisfies exactly one of the two positive conditions: 2D alone fails on one negative group, while 3D alone fails on the other. Improvement in this setting therefore provides more direct evidence of joint 2D–3D reasoning.

AA: topologically distantBB: geometrically close
11Positive
10negative
01negative

However, we acknowledge that these analyses do not directly isolate or quantify the PID synergy term (S). In high-dimensional self-supervised molecular representation learning, such an evaluation would require both a specific PID definition and a reliable estimator conditioned on a predefined downstream target (Y), which is not straightforward in our setting. We therefore interpret the ablations and LR-P3 results as complementary but indirect evidence of improved cross-modal joint reasoning, rather than a direct estimate of synergy. In the revision, we will clarify this scope.


Response to Q5: Pre-training and Inference Costs

For pre-training cost, the current table reports the pre-training data scale rather than computational cost. We will add the available training-cost statistics, including the pre-training scale, epochs, batch size, and reported hardware and wall-clock time.:

Method# MoleculesEpochsBatch SizeReported Hardware / Time
GraphMAE2M100256N/R
Mole-BERT2M100256N/R
GraphMVP50k100256N/R
3D Infomax140kN/R5001× RTX 8000, about 12 h
ChemRL-GEM20M502561× V100, about 8h
MSC-Mol3.4M303841× RTX A6000, about 8 h

For inference, all methods use their learned encoders for downstream prediction. MSC-Mol does not require negative construction, contrastive computation, or reconstruction during inference; therefore, the additional objectives only introduce training-time overhead. The inference cost is comparable to other multimodal molecular encoders with the same input modalities.


We sincerely thank the reviewer again for these constructive comments.

Reviewer_vAzrOpenReview ↗
Rating
5
Clarity
4
Confidence
5
Originality
3
Quality
3
Significance
4
Read review
Summary

This paper presents MSC-Mol, a multimodal molecular pre-training framework that aims to capture cross-modal synergy beyond conventional alignment. It integrates SMILES, 2D graphs, and 3D conformations, and introduces modality-masked views and hard negative samples to encourage fine-grained multimodal consistency. The paper also designs probe tasks to evaluate modality-specific and synergistic information. Experiments on molecular property prediction, DTI prediction, and probe tasks demonstrate its effectiveness.

Strengths and weaknesses

Strengths:

  1. The authors revisit cross-modal alignment from the perspective of synergistic information and show that existing methods mainly strengthen redundant information while overlooking semantics requiring multimodal joint reasoning. The motivation is clear and is supported by systematic probe experiments.

  2. The primary strength lies in the framework. From the perspective of mutual information optimization, the authors introduce a shared fusion space, modality-masked views, and hard negatives to capture both shared and complementary cross-modal information. This design alleviates strong-modality shortcuts and provides a new direction for multimodal molecular pre-training.

  3. The experimental evaluation is comprehensive. The paper reports results on molecular property regression, classification, and DTI prediction, together with ablation studies and targeted probe tasks to analyze module effectiveness and modality contributions.

  4. The authors provide complete experimental code and detailed appendix descriptions of datasets, input features, model settings, masking strategies, and hyperparameters, which improves reproducibility and technical reliability.

Weaknesses:

  1. The theoretical analysis in Section 2.1 is well motivated, but the connection between the mutual-information formulation and the final training objective could be further clarified. Additional derivations or explanations would make the theoretical motivation more convincing.

  2. The probe tasks are interesting and valuable, but the current results are mainly reported as summary metrics. More fine-grained analysis of different probe categories or difficulty levels would help better reveal how MSC-Mol captures synergistic information.

  3. The paper claims that MSC-Mol alleviates strong-modality shortcuts, but the evidence mainly comes from attention distributions and performance comparisons. Additional modality intervention experiments, such as removing or perturbing one modality during inference, would further strengthen this conclusion.

Questions
  1. It would be helpful if the authors could clarify the theoretical link between the mutual-information analysis in Section 2.1 and the final training objective, and provide more rigorous theoretical derivations or proofs. This would strengthen the completeness and persuasiveness of the formal analysis.

  2. I would suggest that the authors supplement more detailed results for the probe tasks, for example across different probe categories or difficulty levels.

  3. It would be useful for the authors to add modality intervention experiments to more directly assess whether MSC-Mol reduces reliance on a single dominant modality.

Limitations

Yes

Paper formatting concerns

The format is OK

Final justification

After carefully considering the authors' rebuttal, I maintain my rating of 5 as my final review.

1 comment

We sincerely thank Reviewer vAzr for the thoughtful review. Your insightful questions have been very helpful in improving the clarity and rigor.

Response to W1: Clarifying the Link Between Mutual Information and the Training Objective

We thank the reviewer for this suggestion. We will clarify the derivation from the mutual-information formulation to the final objective by explicitly mapping each information term to its corresponding loss and stating the required assumptions. Importantly, our objective should be viewed as a tractable surrogate rather than a direct mutual-information estimator.

The Proof[1-3]

2.1 Problem setup. Let X=(X1,X2)X=(X_1,X_2) denote any pair of molecular modalities and YY a downstream task. Although MSC-Mol processes all three modalities, we use the standard two-source PID formulation. A useful representation should preserve I(X;Y)=I(X1,X2;Y).I(X;Y)=I(X_1,X_2;Y).

2.2 Partial Information Decomposition. PID decomposes the task-relevant information in two modalities as

I(X1,X2;Y)=R+U1+U2+S,I(X_1,X_2;Y)=R+U_1+U_2+S,

where RR denotes information redundantly available from both modalities, U1U_1 and U2U_2 denote modality-specific information, and SS denotes information accessible only from their joint observation. Accordingly,

I(X1;Y)=R+U1,I(X2;Y)=R+U2,I(X1;X2;Y)=R−S.I(X_1;Y)=R+U_1, I(X_2;Y)=R+U_2, I(X_1;X_2;Y)=R-S.

Conventional cross-modal contrastive learning typically maximizes an estimator of I(X1;X2)I(X_1;X_2) and is therefore most effective when task-relevant information is largely redundant across modalities.

Definition: Molecular Multiview Redundancy. There exists ε>0\varepsilon>0 such that I(Y;X1∣X2)<εI(Y;X_1\mid X_2)<\varepsilon and I(Y;X2∣X1)<εI(Y;X_2\mid X_1)<\varepsilon.

Lemma 1. Under this assumption, conventional cross-modal contrastive learning is primarily constrained to redundant task-relevant information RR.

This limitation is important for molecular modalities. Pure cross-modal alignment may therefore suppress modality-specific or complementary signals. We instead extend contrastive learning to the joint molecular input.

Assumption 1: Minimal Task-Preserving Molecular Augmentations. There exists a set T⋆\mathcal{T}^{\star} such that, for any t∈T⋆t\in\mathcal{T}^{\star} and X′=t(X)X'=t(X), we have I(X;X′)=I(X;Y)I(X;X')=I(X;Y).

This assumption states that the augmented joint view preserves task-relevant information while discarding task-irrelevant variation. The augmentation is defined over the joint input and is not restricted to independently transforming each modality, allowing coordinated perturbations such as masking different atom regions across modalities.

Let Zθ=fθ(X),Zθ′=fθ(X′),X′=t(X)Z_\theta=f_\theta(X), Z_\theta'=f_\theta(X'), X'=t(X).

The Markov chains X→X′→Zθ′X \rightarrow X' \rightarrow Z_\theta' and Zθ′→X→ZθZ_\theta' \rightarrow X \rightarrow Z_\theta imply

I(Zθ;Zθ′)≤I(X;Zθ′)≤I(X;X′)I(Z_\theta;Z_\theta') \leq I(X;Z_\theta') \leq I(X;X').

Lemma 2. If fθf_\theta is sufficiently expressive and mutual-information maximization reaches its optimum, then $ I(Z_{\theta^\star};Z'_{\theta^\star})=I(X;X')$.

Combining Lemma 2 with Assumption 1 gives

I(Zθ⋆;Zθ⋆′)=I(X;Y)=R+U1+U2+SI(Z_{\theta^\star};Z'_{\theta^\star})=I(X;Y)=R+U_1+U_2+S.

Thus, fused-to-fused contrast is theoretically capable of preserving the complete task-relevant information in the joint input, although it does not explicitly isolate the individual PID components.

We further consider modality selection.

Lemma 3. For the transformation X′=ti(X)=XiX'=t_i(X)=X_i, let Zi=fθ⋆(Xi)Z_i=f_{\theta^\star}(X_i). Then $ I(Z_i;Y)=I(X_i;Y)=R+U_i$

This motivates unimodal-to-fused contrast as a practical mechanism for preserving the task-relevant information accessible from each modality.


Response to W2: Fine-Grained Analysis of Probe Categories and Difficulty Levels

We thank the reviewer for this insightful suggestion. We therefore added difficulty-wise probe results for easy, medium, and hard negatives. The results show that MSC-Mol remains consistently strong as negatives become increasingly ambiguous, with particularly robust performance on the harder settings. This analysis provides finer-grained evidence that MSC-Mol captures complementary topological and geometric information rather than relying on superficial cues.

MethodSetting 1 AP ↑Setting 1 ROC-AUC ↑Setting 2 AP ↑Setting 2 ROC-AUC ↑Setting 3 AP ↑Setting 3 ROC-AUC ↑
1D-Align0.57890.84380.56280.78550.48770.7435
2D-Align0.66620.87860.56950.79620.54880.7880
3D-Align0.89220.97220.66940.87510.67980.8808
P-GUCL0.77280.93510.65250.85550.63250.8433
GUCL0.77840.93160.61620.82160.59370.8046
FusCL0.78690.93450.60860.82600.58500.8023
TriCL0.67360.87540.58160.81750.54930.8039
ParaCL0.91020.97520.71200.87780.68480.8738
Scratch0.69080.88250.49210.73530.48770.7435
MSC-Mol0.93780.98570.72790.89250.71490.8811

Response to W3: Downstream Evaluation under Missing Modalities

We agree that direct missing-modality evaluation is necessary. We evaluated MSC-Mol on six MoleculeNet datasets under full- and missing-modality settings. Compared with the variant without modality-masked positives, MSC-Mol exhibits smaller cumulative degradation (5.5 vs. 8.1 ROC-AUC points), demonstrating greater stability under unavailable modalities.

Available ModalitiesMethodBBBPTox21ToxCastSIDERClinToxBACEAvg.
1D+2D+3DMSC-Mol w/o modality-masked positives72.8±1.374.5±0.668.1±0.364.3±0.897.6±2.284.0±1.576.88
1D+2D+3DMSC-Mol73.9±0.775.1±1.668.5±0.265.1±0.598.7±0.884.4±0.777.62
1D+2DMSC-Mol w/o modality-masked positives71.8±1.571.4±0.563.3±0.461.7±0.995.4±1.781.7±1.474.22
1D+2DMSC-Mol72.6±0.773.0±0.465.8±0.662.7±1.298.0±1.882.2±1.875.72
1D+3DMSC-Mol w/o modality-masked positives71.5±0.672.2±0.863.2±0.660.1±0.394.1±2.083.0±1.374.02
1D+3DMSC-Mol72.6±1.673.1±0.963.3±0.362.3±0.596.7±3.382.8±0.975.13
2D+3DMSC-Mol w/o modality-masked positives71.7±0.873.1±1.164.6±0.461.4±0.593.3±3.782.2±0.674.38
2D+3DMSC-Mol73.2±1.175.2±0.467.5±0.864.3±0.995.8±2.783.4±1.976.57

[1] Dufumier et al., ICLR, 2025.
[2] Liang et al., NeurIPS, 2023.
[3] Tian et al., NeurIPS, 2020.


We sincerely thank the reviewer again for these constructive comments.

Reviewer_kuh2OpenReview ↗
Rating
4
Clarity
3
Confidence
4
Originality
3
Quality
3
Significance
3
Read review
Summary

MSC-Mol is a multimodal molecular pretraining framework over SMILES, 2D graphs, and 3D conformations. Motivated by a partial-information-decomposition view, it argues that cross-modal alignment captures mainly redundant information and misses synergy, and it introduces synergy-aware contrastive negatives (single-modality replacement and modality recombination), a unimodal-to-fused alignment scheme, and a masked reconstruction objective, validated on property prediction, DTI, and a set of probe tasks.

Strengths and weaknesses

Strengths

  1. The synergy framing and the probe tasks are a genuinely useful diagnostic idea, and the observation that simple alignment can underperform concatenated single-modality models is a nice motivation.
  2. The evaluation is broad, covering classification, regression, DTI under random and cluster splits, and a careful set of objective-variant ablations.

Weaknesses

  1. The theoretical motivation is loose, and once the synergy narrative is set aside, the actual mechanism reduces to shared alignment plus private preservation plus cross-modal completion. The fused-to-fused contrast aligns the fused representations (the shared component), the unimodal-to-fused contrast preserves modality-specific information (the private component), and the masked reconstruction with non-overlapping atoms across modalities is effectively a cross-modal completion objective. None of these terms separately estimates or optimizes synergy. The paper only annotates the loss with approximate equalities to the PID components, without a derivation or an estimator, and synergy in PID has several competing and hard-to-estimate definitions. So the synergy claim is an interpretation placed on a shared, private, and completion based objective rather than a quantity that is actually modeled and verified.
  2. Beyond the lack of an explicit synergy estimator, it is unclear that meaningful PID synergy even exists in this setting. SMILES, 2D graph, and 3D conformer are largely deterministic re-encodings of the same molecule, so their joint information is dominated by redundancy plus some 3D-specific unique information rather than synergy in the strict sense. The paper does not distinguish synergy from unique 3D information, and its flagship probe (2D-distant but 3D-close pharmacophore pairs) is equally explainable as unique 3D geometric information conditioned on the 2D graph. As a suggestion rather than a requirement, the synergy claim might be made more convincing by considering a genuinely independent modality, for example a biological or cellular readout, since such modalities are not deterministic functions of structure and are where real synergy is more plausible. Text descriptions would be a weaker choice, since they are often themselves derived from structure and largely redundant.
  3. The paper lists usability under missing modalities as one of its four core design requirements and builds modality-masked positive views to support it, but provides no downstream experiment that evaluates performance under missing or single modalities, for example structure-only or without the 3D conformer. After a full-text check, no such result appears. Since this is presented as a core goal, a direct missing-modality downstream evaluation would be needed to substantiate the claim.
  4. There are factual errors in the main classification table. The molecule-count and task-count rows are misaligned with the dataset columns and are inconsistent with the appendix statistics, and the molecule-count row ends with 41127, which is the count for HIV, a dataset that is not one of the six columns. These should be corrected.
  5. Some of the modality labels in Table 2 may be inaccurate. For example, MolCLR and GROVER are usually regarded as 2D graph based methods but appear to be labeled as 3D, and MoleculeSDE is commonly described as a 2D plus 3D multimodal method but seems to be labeled as 2D. It would help to double-check these labels, since they affect how the reader interprets the fairness of the modality comparison.
  6. The benchmark coverage on MoleculeNet is incomplete. The paper uses many of the standard datasets but omits the larger classification benchmarks such as HIV, MUV, and PCBA, as well as the quantum regression sets QM7, QM8, and QM9. Given that the HIV molecule count even appears by mistake in the main table, HIV results seem to have been expected but are not reported. Evaluating on the full MoleculeNet suite would give a clearer picture of whether the gains are general.
  7. The comparison does not include several recent multimodal molecular representation methods, for example Atomas and TRIDENT. These works also move beyond simple instance-level contrastive alignment toward more structured or geometry-aware alignment objectives, which is closely related to the motivation here, so they should be discussed and, where the downstream tasks overlap, compared.
  8. The DTI evaluation reports a warm (random) split and a cross-domain cluster split, but not the intermediate drug-cold (unseen drug) and target-cold (unseen protein) settings. Reporting all of warm / drug-cold / target-cold / both-cold, with per-setting sample sizes, would localize which axis the model actually generalizes on, rather than only contrasting fully-seen with fully-novel.
Questions

See Weaknesses

Limitations

See Weaknesses

Paper formatting concerns

N/A

Final justification

I thank the authors for their detailed rebuttal. My main concerns have been addressed, and I have raised my score accordingly.

1 comment

We sincerely thank Reviewer kuh2 for the thoughtful review. Your insightful questions have been very helpful in improving the clarity and rigor.

Response to W1: Scope of the Synergy Claim

We thank the reviewer for this important clarification. We agree that MSC-Mol does not directly estimate, disentangle, or explicitly optimize the PID synergy term S. The fused-to-fused contrast, unimodal-to-fused contrast, and masked reconstruction losses are practical self-supervised objectives rather than estimators of individual PID components. We will therefore remove the approximate PID annotations in Eq. (19) and revise statements that may overstate the correspondence between these objectives and R, Um, or S.

Our theoretical result should instead be interpreted as an information-preservation statement under idealized assumptions. If the augmented view preserves all task-relevant information and mutual-information maximization reaches its optimum, then the fused representation can preserve the information contained in the joint input, including synergy when it exists. This does not imply that MSC-Mol isolates or quantitatively estimates S. In practice, the proposed objectives act as inductive biases that preserve modality-specific information, reduce dominant-modality shortcuts, and encourage fine-grained cross-modal consistency and completion. We will clarify this scope and use the more precise term “cross-modal joint information” when a strict PID interpretation is not established.


Response to W2: Synergy versus Unique 3D Information

We thank the reviewer for this fundamental concern. We agree that SMILES, 2D graphs, and 3D conformers are strongly coupled views of the same molecule rather than statistically independent modalities. Our point is only that they are not information-equivalent: 2D topology does not uniquely determine a molecular conformation, while a single 3D conformer does not provide all symbolic and topological information in an equally accessible form.

We also agree that LR-P3 is not a direct estimator of PID synergy and that unique 3D information may contribute to its performance. We therefore interpret it as a controlled cross-modal joint-reasoning probe. Its label requires both topological distance and geometric proximity, and the medium-difficulty negatives (Line 618 in the paper) satisfy only one condition, making neither 2D nor 3D information alone sufficient. Thus, the results support improved joint use of topology and geometry, but do not uniquely identify the PID synergy component. We will revise the terminology accordingly, acknowledge this limitation, and note that more independent biological or cellular modalities would provide a stronger setting for studying synergy in the strict PID sense.


Response to W3: Downstream Evaluation under Missing Modalities

We agree that direct missing-modality evaluation is necessary. We evaluated MSC-Mol on six MoleculeNet datasets under full- and missing-modality settings. Compared with the variant without modality-masked positives, MSC-Mol exhibits smaller cumulative degradation (5.5 vs. 8.1 ROC-AUC points), demonstrating greater stability under unavailable modalities.

Available ModalitiesMethodBBBPTox21ToxCastSIDERClinToxBACEAvg.
1D+2D+3DMSC-Mol w/o modality-masked positives72.8±1.374.5±0.668.1±0.364.3±0.897.6±2.284.0±1.576.88
1D+2D+3DMSC-Mol73.9±0.775.1±1.668.5±0.265.1±0.598.7±0.884.4±0.777.62
1D+2DMSC-Mol w/o modality-masked positives71.8±1.571.4±0.563.3±0.461.7±0.995.4±1.781.7±1.474.22
1D+2DMSC-Mol72.6±0.773.0±0.465.8±0.662.7±1.298.0±1.882.2±1.875.72
1D+3DMSC-Mol w/o modality-masked positives71.5±0.672.2±0.863.2±0.660.1±0.394.1±2.083.0±1.374.02
1D+3DMSC-Mol72.6±1.673.1±0.963.3±0.362.3±0.596.7±3.382.8±0.975.13
2D+3DMSC-Mol w/o modality-masked positives71.7±0.873.1±1.164.6±0.461.4±0.593.3±3.782.2±0.674.38
2D+3DMSC-Mol73.2±1.175.2±0.467.5±0.864.3±0.995.8±2.783.4±1.976.57

Response to W4-5: Corrections to Dataset Statistics and Modality Labels

We thank the reviewer for identifying these errors. The molecule- and task-count rows in Table 2 were inadvertently misaligned. We will correct the statistics for BBBP, Tox21, ToxCast, SIDER, ClinTox, and BACE to 2,039/1, 7,831/12, 8,575/617, 1,427/27, 1,478/2, and 1,513/1 molecules/tasks, respectively. These are the correct statistics for the datasets used in our experiments.

We also rechecked the modality annotations against the original methods. MolCLR, GROVER, and GraphMAE will be corrected to 2D, while MoleculeSDE will be corrected to multimodal (2D+3D). We further audited all remaining baselines to ensure consistent categorization of 2D, 3D, and multimodal methods. These corrections are limited to dataset metadata and modality annotations and do not affect the reported experimental results or our conclusions.


Response to W6-7: Benchmark Coverage and Recent Baselines

We thank the reviewer for this helpful suggestion. We have added results on HIV and MUV, corrected the dataset statistics, and included Atomas and TRIDENT where directly comparable results are available.

We agree that PCBA and QM7/QM8/QM9 would further broaden the evaluation. However, most baseline results are taken from the standardized settings of MoleBlend and M2UMol, where these datasets are not consistently reported. Adding only a subset of reproduced results could introduce confounding differences in splits and optimization. We therefore focus on benchmarks with broad and comparable coverage.

Dataset / Method# N_MolModBBBPTox21ToxCastSIDERClinToxBACEHIVMUVAvg.
# Molecules——2,0397,8318,5751,4271,4781,51341,12793,087—
# Tasks——1126172721117—
MolCLR10M2D66.6 (1.8)73.0 (0.1)62.9 (0.3)57.5 (1.7)86.1 (0.9)71.5 (3.1)76.3 (2.4)72.5 (2.3)70.8
GROVER10M2D70.0 (0.1)74.3 (0.1)65.4 (0.4)64.8 (0.6)81.2 (3.0)82.6 (0.7)62.5 (0.9)67.3 (1.6)71.0
GraphMVP50K2D+3D68.5 (0.2)74.5 (0.4)62.7 (0.1)62.3 (1.6)79.0 (2.5)76.8 (1.1)74.8 (1.4)75.0 (1.4)71.7
3D InfoMax140K2D+3D69.1 (1.0)74.5 (0.7)64.4 (0.8)60.6 (0.7)79.9 (3.4)79.7 (1.5)76.1 (1.3)74.4 (2.4)72.3
GraphMAE2M2D72.0 (0.6)75.5 (0.6)64.1 (0.3)60.3 (1.1)82.3 (1.2)83.1 (0.9)77.2 (1.0)76.3 (2.4)73.9
Mole-BERT2M2D71.9 (1.6)76.8 (0.5)64.3 (0.2)62.8 (1.1)78.9 (3.0)80.8 (1.4)78.2 (0.4)78.6 (1.8)74.0
MoleculeSDE3.4M2D+3D71.8 (0.7)76.8 (0.3)65.0 (0.2)60.8 (0.3)87.0 (0.5)79.5 (2.1)78.8 (0.9)80.9 (0.3)‾\underline{80.9\ (0.3)}75.1
MoleBlend3.4M2D+3D73.0 (0.8)77.8 (0.8)66.1 (0.0)64.9 (0.3)87.6 (0.7)83.7 (1.4)79.0 (0.8)77.2 (2.3)76.2
M2UMol11.6K2D+3D+Text+Bio68.2 (0.6)76.2 (0.1)66.3 (0.5)66.0 (0.8)92.9 (0.5)84.3 (1.4)‾\underline{84.3\ (1.4)}80.5 (0.8)79.0 (1.0)76.7
Atomas51.3KSMILES+Text73.7 (1.7)77.9 (0.4)‾\underline{77.9\ (0.4)}66.9 (0.9)64.4 (1.9)93.2 (0.5)83.1 (1.7)80.6 (0.4)76.3 (0.7)77.0
TRIDENT47.3KSMILES+Text+HTA74.0 (1.0)79.4 (0.1)67.8 (0.4)‾\underline{67.8\ (0.4)}63.6 (0.6)95.4 (0.7)‾\underline{95.4\ (0.7)}82.4 (0.6)81.6 (0.5)83.5 (0.5)78.5
MSC-Mol-w/o pretrain—SMILES+2D+3D65.1 (0.4)72.7 (1.2)62.9 (1.0)61.3 (0.9)89.2 (3.1)79.5 (1.3)75.5 (2.3)74.9 (1.7)72.6
MSC-Mol3.4MSMILES+2D+3D73.9 (0.7)‾\underline{73.9\ (0.7)}75.1 (1.6)68.5 (0.2)65.1 (0.5)‾\underline{65.1\ (0.5)}98.7 (0.8)84.4 (0.7)80.8 (1.7)‾\underline{80.8\ (1.7)}79.2 (1.1)78.2‾\underline{78.2}

Values in parentheses follow the uncertainty measure reported in the original papers; notably, Atomas reports 95% confidence intervals.

MSC-Mol remains competitive, although it is weaker than TRIDENT on some tasks. This comparison is not information-equivalent: Atomas and TRIDENT incorporate external molecular descriptions, and TRIDENT additionally uses hierarchical taxonomic annotations, whereas MSC-Mol relies only on intrinsic structural views. The observed gap may therefore partly reflect differences in available pre-training information, in addition to differences in architecture and optimization.

Response to W8: DTI evaluation

We now additionally include drug-cold and target-cold evaluations to directly assess generalization to unseen entities. For a fair comparison, we re-evaluate M2UMol using the same data partitions and training protocol.

DatasetSplitTrain / Val / TestM2UMol AUROC / AUPRCOurs AUROC / AUPRC
BindingDBDrug-cold39016 / 5092 / 509161.2±4.2 / 56.1±3.365.1±5.1 / 59.5±4.3
BindingDBTarget-cold39028 / 5131 / 504074.4±3.5 / 68.2±2.876.8±3.7 / 73.4±3.2
BioSNAPDrug-cold22393 / 2535 / 253569.5±2.6 / 85.7±3.974.8±1.9 / 89.4±2.3
BioSNAPTarget-cold22038 / 2713 / 271255.4±1.7 / 73.9±4.457.7±2.6 / 78.4±3.2

We sincerely thank the reviewer again for these constructive comments.

Comments on the paper

1 comment
Meta-review

The paper proposes a multimodal molecular pre-training framework that integrates SMILES, 2D graphs, and 3D conformations through modality perturbation, hard-negative construction, and masked reconstruction. The reviewers recognize the broad evaluation, but the connection between the training objectives and the central cross-modal synergy claim requires further clarification. For example, the authors should explain how the method distinguishes synergistic information from modality-specific information or gains due to stronger augmentation and negative sampling. The authors should also provide more direct evidence regarding robustness to missing or perturbed modalities. Clarification of the probe-task relevance, comparison with closely related multimodal methods, and correction of the reported dataset and modality labels would also strengthen the paper.

The rebuttal resolves most of the concerns, and the additional analyses further strengthen the paper. The authors are encouraged to incorporate the clarifications and additional results into the revised manuscript.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.