Summary
Summary This manuscript introduces LUMOS, a VAE-based framework designed to decompose time-resolved Raman spectroscopy into Raman peaks, distinct fluorescent components, and noise. The authors position this work as the first to address short, incomplete bleaching sequences in an unsupervised fashion. Evaluation on both simulated and real-world datasets demonstrates performance gains over algorithmic baselines (AirPLS, iModPoly) and certain supervised alternatives.
Strengths and weaknesses
Strengths (1) The work addresses a highly practical challenge in Raman spectroscopy—reducing acquisition time by leveraging partial bleaching dynamics. This has clear applicability to high-throughput settings. (2) The integration of domain-specific physics (Voigt profiles, exponential decay) with a probabilistic latent-variable model is logically consistent and well-motivated.
Weaknesses (1) Incremental Methodological Contribution: My primary concern lies in the novelty of the approach. LUMOS effectively aggregates several established components: a standard VAE backbone, a physics-informed decoder, fixed Voigt parameterizations, exponential decay kinetics, and a Poisson-Gaussian noise model. While the engineering required to unify these elements for Raman data is non-trivial, the core machine learning methodology feels evolutionary. The manuscript acknowledges similarities to prior physics-informed autoencoders; however, the shift to a VAE framework and the inclusion of temporal bleaching sequences do not constitute a fundamental architectural or theoretical advance. (2) Potential Evaluation Bias: The synthetic data generation pipeline appears to mirror LUMOS’s internal generative assumptions (exponential decay, specific fluorophore mixtures, Voigt peaks, and Poisson-Gaussian noise). This alignment likely grants the model an inherent advantage. A stronger evaluation would include significant model mismatch scenarios. Without such analyses, it is difficult to determine whether the gains arise from genuine robustness or from matching the simulation assumptions. (3) Limitations of Real-World Validation: The real-data experiments rely on a relatively small set (266 filtered sequences across four classes). More critically, the "ground truth" Raman spectra used for benchmarking are derived from post-processed late-frame averages (baseline corrected and smoothed). Since this reference is itself an estimate rather than a true physical ground truth, the reported quantitative improvements on real data should be interpreted cautiously. (4) The Nature of "Unsupervised" Learning: The emphasis on "unsupervised" training is somewhat misleading. The model incorporates strong physical priors, including a fixed number of fluorophores, pre-defined peak shapes, and noise distributions. It is worth discussing how the method remains "unsupervised" when so many hyperparameters require expert tuning. Additionally, the manuscript does not convincingly demonstrate a scenario where this approach succeeds where supervised methods fail.
Questions
Questions (1) Can the authors clarify what they consider the primary methodological novelty beyond combining existing VAE frameworks with established Raman physics models? (2) How sensitive is LUMOS to violations of the exponential bleaching assumption? (3) Have the authors evaluated the model under realistic distribution shifts where fluorophore spectra or bleaching dynamics differ substantially from the training data?
Limitations
Yes
Paper formatting concerns
No
We thank the reviewer for their insightful feedback and will address the points below.
Novelty
We appreciate the reviewer's scrutiny here and would like to clarify what we consider to be the primary contribution of our work. We would first note the use-inspired track's framing of originality, which states that originality "need not mean wholly novel methods" and may consist of "a novel combination of existing methods to match the characteristics of the data, or a novel way of framing a stereotypical ML problem due to the particular needs of the use case." We believe LUMOS meets this criterion on several fronts. The problem itself is new: to our knowledge, no prior work addresses recovery of Raman spectra from short, incomplete photobleaching sequences, and the data type this requires did not previously exist, which is why we introduce it. The central insight, that an incomplete, unbleached decay sequence already contains sufficient information to separate constant Raman signals from decaying fluorescence, without waiting for complete bleaching is, we believe, new.
Importantly, we have now run additional experiments to probe how much our forward model itself, or its combination with a trained VAE contribute to overall performance. As such, we directly optimized parameters for each sample in the cancer dataset, instead of training a VAE. While VAE-based LUMOS achieves a Pearson correlation of 0.93 for the predicted Raman spectrum, the direct optimization yields a score of 0.49; and 0.68 when providing the true sample fluorophores. Only when we additionally provide the true decay rates and abundances for each sample did the direct fitting achieve a similar performance as LUMOS (0.91). Note that this latter case is highly unrealistic and effectively already removes the baseline, leaving the trivial task of fitting the Raman residual.
While LUMOS’ VAE-based architecture can learn a prior distribution of which patterns and correlations are likely to occur in the data by combining information from the whole training set, the non-amortized fitting does not have this benefit and has to separately process each sample, resulting in inferior results.
Evaluation bias and robustness to model mismatch
‘The synthetic data generation pipeline appears to mirror LUMOS’s internal generative assumptions (exponential decay, specific fluorophore mixtures, Voigt peaks, and Poisson-Gaussian noise)’
It is true that we use the established model (TODO CITE PAPER) of exponentially decaying fluorophores in our VAE and simulation pipeline. However, this is not the case with respect to the Raman spectra themselves. While our VAE assumes a combination of Voigt profiles, our simulated data uses real spectra from various sources without assuming a mixture of Voigt shapes. Regarding the noise model, we use Poisson Gaussian noise in our simulation, but a Gaussian approximation with variable linear variance in our VEA. Again, Possion-Gaussian noise and this approximation are well established model [ ZLFW23 ]. Importantly, in order to avoid an incorrect positive evaluation based on matching unrealistic models, we present a novel non-simulated directly measured Raman bleaching dataset, which will be published upon acceptance of the paper. We would like to highlight that our model outperforms its competitors in both, the real and simulated datasets. The strongest evidence against "the gains merely reflect matched assumptions" is that they persist on data we did not generate. We welcome any suggestions as to which aspect of our forward model could be more realistic and how it could be further improved to avoid spurious results.
Limitations of real-world validation
We agree with the reviewer, and this is the most important caveat in the evaluation. There is no true physical Raman ground truth for live cells - the residual fluorescence in incomplete bleaching is intrinsic to the problem addressed by the paper - so the late-frame average is a necessary estimated reference rather than a physical one. We would add that baseline subtraction and Savitzky–Golay smoothing of weak Raman signals is standard practice, so the estimate is constructed in the conventional way rather than tuned to favour our method; if anything, constructing the reference with the same SavGol and baseline-subtraction steps that the classical methods themselves use may favour those baselines rather than LUMOS. On dataset size, we agree it is modest; strong performance in this low-data regime is itself part of the contribution: that an unsupervised model can compete with industry-standard and state-of-the-art supervised methods on so few samples is unusual, and would not be possible without the physical priors.
The "unsupervised" framing
We take this point and would like to make a clear distinction. LUMOS uses no labels and never observes a clean Raman spectrum; its only supervision signal is the physical contrast that the Raman component is constant while fluorescence decays according to a known process. In the standard sense, learning without labelled targets is unsupervised learning. The reviewer is correct that the model carries strong physical priors, but we would distinguish inductive bias from supervision: strong priors narrow the hypothesis space rather than providing labels. We regard this as a strength rather than a weakness, since it is what facilitates efficient and transparent training from few examples. We would additionally add that these priors are not per-dataset tuned - the same configuration and hyperparameters are used across all datasets without adjustment.
Finally, on the reviewer's related point that we do not demonstrate a scenario where the unsupervised approach succeeds and supervised methods fail: on the real dataset, LUMOS outperforms both supervised RADAR variants (pretrained and finetuned) on PSNR, SI-PSNR, Pearson, SAM, AUPRC and Max F1, despite using no labels.
We thank the reviewer again for the depth of the review and hope these clarifications and additional results address the concerns raised
Questions:
Q1. Can authors clarify the primary methodological novelty beyond combining existing methods?
The primary methodological novelty is addressed in our response to weakness 1. In brief: LUMOS is, to our knowledge, the first unsupervised model to recover Raman spectra from short, incomplete photobleaching sequences, a problem and data type that did not previously exist, and our per-sample optimisation experiment shows the physics-plus-amortisation combination resolves a decomposition degeneracy that neither component achieves alone.
Q2 & Q3. How sensitive is LUMOS to violations of the model assumptions?
Sensitivity to assumption violations and to distribution shift are closely related, and we address both in our response to weakness 2. In brief: the real dataset is generated by an unknown physical process that departs from the model's idealised assumptions, and LUMOS's strong performance there is evidence of robustness to such violations. As we note in weakness 2, a controlled model-mismatch study would strengthen this further, and we see it as a clear next step.
We thank the reviewer again for the depth of the review and hope these clarifications and additional results address the concerns raised.