acceptodds
Published as a conference paper at NeurIPS 2026

Lifting Biomolecular Data Acquisition

Eli N. Weinstein, Andrei Slabodkin, Mattia G Gollub, Kerry Dobbs, Xiao-Bing Cui, Fang zhang, Kristina Gurung, Elizabeth B Wood

Abstract

One strategy to scale up ML-driven science is to increase wet lab experiments' information density. We present a method based on a neural extension of compressed sensing to function space. We measure the activity of multiple different molecules simultaneously, rather than individually. Then, we deconvolute the molecule-activity map during model training. Co-design of wet lab experiments and learning algorithms provably leads to orders-of-magnitude gains in information density. We demonstrate on antibodies and cell therapies.

Keywords:
Paris

Reviews

Among:
Shape:
123456this paper, Top 24%
Figure 1. Mean review rating of the reviewed papers at NeurIPS 2026. This paper averages 4.67 over 3 reviews, above 76% of the others.
Reviewer_eDvfOpenReview ↗
Rating
5
Clarity
3
Confidence
3
Originality
3
Quality
3
Significance
3
Read review
Summary

The paper proposes LIFT, a combined wet-lab protocol and training algorithm that increases the information density of high-throughput biological screens. Rather than measuring one molecule per experiment, LIFT measures mixtures of many sequences in each cell and observes only their aggregate activity; because the observation is linear in the unknown activity map, learning it becomes a compressed-sensing problem (random mixtures plus a sparsity-encouraging L1 penalty), trained as a "functional, neural LASSO." A neural network parameterizes the map, so the screen yields a model that generalizes to unseen molecules — unlike prior compressed screens that recover a fixed per-molecule vector. The approach is supported with theory, synthetic experiments, and a real wet-lab screen of antibodies against a cancer target.

Strengths and weaknesses

Strengths

  1. Clean and useful reframing: lifting compressed sensing to a neural function turns a pooled screen into a model that generalizes to unseen molecules, which prior compressed-screening work does not. Treating the experiment design and the learning algorithm as a single co-designed system is a genuinely helpful framing for the bio-ML community.
  2. Real wet-lab validation on a hard, therapeutically relevant target, not just simulation — this is rare in ML venues and is the paper's strongest practical contribution. The finding that the experiment design and the algorithm help only in combination (neither alone) is clean and convincing.
  3. Clearly written, with an honest limitations section and a coherent theory→synthetic→wet-lab arc.

Weaknesses

W1 — The theory does not cover the method's main novelty. The formal guarantees are derived for a simplified, linear version of the model; the neural network that learns features and generalizes to unseen molecules — the actual contribution — is supported only empirically. The headline claim that mixtures multiply the effective dataset size should be read as proven for the simplified case and demonstrated, rather than proven, for the full method.

W2 — The empirical validation is somewhat narrow. The wet-lab demonstration is on a single target with modest absolute performance, and the comparison across mixture sizes is largely obtained by subsampling one dataset rather than by running separate experiments. A second target or more direct evidence would make the practical case considerably stronger.

Questions
  1. (W1) The theory is proved for a simplified linear model, not for the neural network that is the actual method. Could you state this explicitly, so the efficiency claim is not read as proven for the full method?
  2. (W2) The comparison across mixture sizes is obtained by subsampling a single dataset — could you clarify what this can and cannot establish, and whether any data you already have speaks to broader generalization?
Limitations

The authors discuss the main assumptions (activities add up, the activity map is sparse, very high mixing can be toxic). The two points I would highlight are that the theory covers a simplified version rather than the neural method that is the central claim, and that the wet-lab evidence rests on a single target.

Paper formatting concerns

N/A

Final justification

I thank the authors for the thorough response and for running substantial additional laboratory experiments during the discussion period. Both points are addressed to a meaningful degree, and I have raised my rating accordingly.

Reviewer_chhAOpenReview ↗
Rating
4
Clarity
3
Confidence
4
Originality
3
Quality
3
Significance
3
Read review
Summary

LIFT is a neural-network method built on compressed sensing, which the authors extend from vectors to function space. They target the inefficiency of biological screening, where pairing single protein sequences with measured activities wastes a limited experimental budget. They propose pooling multiple sequences per measured cell, then deconvolving each sequence's contribution during training, to extract more information per experiment. Theoretically, they show that if the sequence-activity map is sparse, the mixture can be recovered, using an L1 regularizer to enforce sparsity; the analysis reduces the network to a decision-tree form for tractability, while the experiments use a CNN. They evaluate on synthetic and real wet-lab data, comparing against conventional single-sequence training with the same architecture.

Strengths and weaknesses

Strengths:

  • Targets a real, important screening bottleneck, on a hard therapeutically-relevant target (TCRm / intracellular antigens). Significance is the standout.
  • The reframing from regression-on-points to regression-on-mixtures is genuinely novel; theory is principled and assumptions clearly stated. (Note: I followed the structure but did not verify then appendix proofs.)

Weaknesses:

  • Theory proves the efficiency result for a fixed-feature decision-tree reduction while the method and all experiments use a feature-learning CNN. The gap seems to be undiscussed.
  • Baseline is conventional single-sequence training on split data, near worst-case, with no comparison to the pooled-screening methods that are cite.
  • The real-data MOI trend is manufactured by subsampling one experiment. Gains are relative on a near-floor base (≈0.09, ablation 0.006) with absolute significance underdiscussed.
Questions
  • Can you say anything about how the coherence result behaves when features are learned rather than fixed?
  • Can you isolate the method effect from the data-quantity effect in the real-data MOI comparison, or run independent experiments at distinct MOIs?
  • Please consider adding further (stronger) baselines?
Limitations

Additivity breaks under molecular interaction; sparsity breaks with graded outcomes; toxicity caps MOI (Those are already discussed in the paper, where they are candid). However, the weaknesses are under discussed and should be reassessed.

Paper formatting concerns

None

Final justification

I appreciate that the authors addressed my questions, as already mentioned by reviewer xUto. Thank you for performing the additional wet-lab experiments, I see the remaining limitations as minor. I raised my score from 3 to 4, yet I still point at the issue of non-linear interactions in function space, which is common in biology.

Reviewer_xUtoOpenReview ↗
Rating
5
Clarity
4
Confidence
3
Originality
3
Quality
3
Significance
3
Read review
Summary

The paper proposes LIFT, a co-designed experiment-and-algorithm pair for high-throughput biomolecular screening. Classical experimentation tests one perturbation per measurement; LIFT delivers multiple perturbations per cell, observes an additive activity readout, and deconvolutes the contributions during training of a neural sequence-to-activity model with an L1 function-space penalty. The authors frame this as a neural extension of compressed sensing, prove that under a decision-tree reduction the effective dataset size scales linearly with perturbation multiplicity, and validate with synthetic antibody data and a real wet-lab binding screen.

Strengths and weaknesses

I am an applied researcher and insufficiently conversant in the compressed sensing literature to critique its deployment here. My evaluation centers on two issues in the empirical comparisons that I believe are serious as the manuscript stands. I am willing to revise my rating upward if they are addressed.

Strengths:

  1. Excellent problem framing. The core idea is genuinely well-motivated: if the sequence-activity map is sparse -- most sequences are inactive -- then testing one at a time wastes most measurements on zeros. Pooling multiple sequences per readout turns the sparsity, normally an obstacle, into a source of information gain. This also converts a practical experimental nuisance (multiple infections per cell) into a designed advantage rather than something to be discarded. That reframing is the paper's best feature.

  2. The theory gives rise to an actionable experimental knob (the MOI), and satisfyingly confirms intuition.

  3. Real wet-lab validation. This is beyond the scope of most NeurIPS submissions and is appreciated.

Weaknesses:

  1. The conventional baseline is fed labels that manufacture its degradation with MOI (lines 239–240). To train the conventional baseline on multi-sequence cells, the authors split each datapoint ({xi1, xi2, ...}, yi) into (xi1, yi), (xi2, yi), … -- i.e., every sequence in a pooled cell inherits the cell-level readout as its individual label. Under the paper's own sparsity premise, most of those sequences are inactive. So this injects label noise that grows with MOI: at MOI 10, a single positive cell teaches the model that roughly nine inactive sequences are active. This raises suspicion that the downward slope of the conventional curve in Figures 2 and 3 (which the paper uses as evidence that pooling helps) is an artifact of the label-splitting scheme, not of pooling per se. The authors are using the baseline's collapse to argue for LIFT, when that collapse is plausibly manufactured by how the baseline is fed data.

By comparison, the authors construct their test set for the wet-lab experiment by rejecting cells with mi>1 (line 270). While I cannot speak to the antibody design context, standard preprocessing in single-cell CRISPR screens also excludes cells that aren't confidently single-perturbation. An honest comparison would therefore compare LIFT against a conventional pipeline that discards multiplets, instead of the label-splitting scheme. Benchmarking against a pipeline that discards multiplets would, I expect, still favor LIFT at high MOI.

  1. The headline wet-lab result rests on a single point with no quantified uncertainty (Figure 3). The error bars in Figure 3 are described as standard error across random draws of lower-MOI datasets. But the highest-MOI point (1.203) is the full dataset, so no draws exist and no uncertainty is shown. That point is where LIFT visibly separates from conventional training and is the sole basis for the "50-100% improvement in hit rate" claim in the abstract and discussion. The authors need to supply a valid uncertainty quantification at this decisive operating point; I leave the appropriate construction to the authors, but note that whatever is used must apply uniformly across the MOI axis, so that the comparison driving the headline claim is between quantities of the same kind.
Questions
  1. Does the conventional baseline receive the L1 / sparsity penalty? LIFT bundles two things: increased treatment multiplicity and the L1 regularizer. L1 is generic regularization that helps many estimators, and the paper's own ablation shows it is doing enormous work: dropping the LeaVS/L1 term collapses AUPRC from 0.092 to 0.006 (lines 276-277). If the conventional baseline is not regularized identically, a large fraction of the measured gain may be the regularizer rather than the pooling. Please state explicitly whether the penalty is applied identically across both arms.

  2. Why was the wet-lab validation confined to MOI = 1.2, given that the synthetic results locate the method's advantage at substantially higher MOI? Was this regime chosen to make linearity a more realistic assumption? Is the ceiling toxicity, per the limitations section? In either case, can the high-MOI claim be considered wet-lab-validated at all?

  3. Is the uniform-partition assumption a genuine restriction? Proposition 5.5 assumes p(x ∈ Vd) = 1/D. Since the partition Vd can in principle be defined arbitrarily, is the uniform-mass assumption a real constraint on the result, or is it broad enough to be vacuous? A sentence on how to think about D and the partition for a real sequence library would clarify what the theorem is actually asserting.

Limitations

yes

Paper formatting concerns

None

Final justification

My review rested on two objections and I committed to raising my rating if both were addressed. These have been resolved:

W1: baseline construction. The original conventional baseline inherited cell-level labels for every sequence in a pooled cell, injecting label noise that grows with MOI. The authors reran both wet-lab (Table 1) and synthetic (Table 2) comparisons against a baseline that discards multiplets. The conventional arm still degrades with MOI, now for a legitimate reason (data loss). The claim that pooling helps survives the corrected comparison. W2: uncertainty. The abstract's hit-rate claim rested on a single unreplicated point. The authors replaced it with a substantial wet-lab validation across multiple targets. Direction and rough magnitude of the effect are consistent across all of them. Q1: identical L1 regularization is confirmed in the baseline model.

Unresolved:

I agree with Reviewers chhA and eDvf critique of the theory (that it covers a fixed-feature reduction while the method uses a feature-learning CNN). The Naderi & Plan extension narrows this but assumes Gaussian measurements and finite parameterization. The authors now acknowledge the gap rather than closing it. I see this as a minor issue -- I do not demand practically useful guarantees in this context -- but I did not evaluate it independently.

I am raising my rating to 5.

Comments on the paper

1 comment
Meta-review

This paper proposes increasing information density in wet-lab science by measuring multiple molecules' activity simultaneously (rather than one at a time) and using a neural extension of compressed sensing to function space to deconvolute the molecule-activity map during model training.

Strength:

  • The problem studied in the paper is important and interesting
  • The paper is well-written
  • The paper includes results from real wet-lab experiments. This is beyond the scope of most NeurIPS submissions and is appreciated.
  • Honest limitations section

Weaknesses:

  • The reviewers raised concerns about comparison to benchmark methods: "An honest comparison would therefore compare LIFT against a conventional pipeline that discards multiplets, instead of the label-splitting scheme"
  • The empirical validation is somewhat narrow: "The wet-lab demonstration is on a single target with modest absolute performance, and the comparison across mixture sizes is largely obtained by subsampling one dataset rather than by running separate experiments. A second target or more direct evidence would make the practical case considerably stronger."
  • Uncertainty quantification is missing
  • "The theory proves the efficiency result for a fixed-feature decision-tree reduction, while the method and all experiments use a feature-learning CNN. The gap seems to be undiscussed."

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Related papers

Loading the map…

Discussion (0)

Sign in to comment.