- Rating
- 4
- Clarity
- 1
- Confidence
- 1
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
In a network of language agents, especially in sensitive applications such as healthcare, transferring more information than necessary creates a governance problem. The manuscript proposes a method called ScopeSelect, which employs hard masking, cost-benefit greedy selection, threshold calibration in CRC and receipt-bound handoff to transfer only the important and necessary context. Comprehensive evaluations are conducted on the HealthHandoffBench and SyntheaHH benchmarks.
Strengths and weaknesses
Strengths:
- The paper addresses an important and timely problem. The growing use of collaborative AI agents, especially in privacy-sensitive domains such as healthcare and medicine makes it increasingly necessary to control what information is shared, with whom, and for what purpose.
- The experimental evaluation is extensive and covers multiple dimensions of the proposed problem. The authors evaluate ScopeSelect on HealthHandoff-Bench, comprising over 21K synthetic handoff tasks across multiple healthcare workflows, Synthea-HH, as well as human-anchored rubric audit. Evaluation includes analyses of privacy–utility trade-offs, calibrated selection, robustness to label noise, distribution shift, and adversarial attacks.
Weaknesses:
- The paper is difficult to read and follow because it combines many technical elements, including authorization, submodular optimization, calibration, and audit mechanisms, without always making their connections clear.
- The clarity and presentation need improvement. The main text should be self-contained. In its current form, it is difficult to understand the details of the proposed method, the experimental settings, and the baseline comparisons without reading the appendix A1–A32.
Questions
Questions and comments:
-
The paper assumes readers are fresh on CRC, FHIR scopes, and agent handoff. A short subsection on background / preliminaries would help a lot to enhance readability.
-
In its current form, understanding the main claims requires frequent jumps across many appendix sections. Adding a claims-to-evidence table, moving all essential definitions into the main text, and clearly separating appendices needed for the core theoretical/experimental claims from stress tests and implementation details would help readability and organization of the main text.
-
If possible, please include a small running example (e.g., visual diagram) of the method. A toy handoff with a few (e.g., 5–8) memory items, showing which are masked, which are selected, and how CRC chooses the threshold, would make the proposed framework much easier to follow.
-
In the experiments section, could you provide an overview and description of the compared baselines before discussing the results?
Limitations
Yes
Paper formatting concerns
None
Final justification
The authors responded to the suggestions I raised to make the paper more accessible to a broader health+AI audience and to improve its overall readability and flow. I therefore maintain my positive score.
Thank you for the constructive review. We agree that the current paper is difficult to follow because it combines authorization, submodular optimization, CRC, agent handoff, and audit mechanisms too densely. We will substantially improve readability and make the main text self-contained.
First, we will add a short preliminaries/background subsection covering the terms the current draft assumes: agent handoff, receiver capability contract, scope token, memory layer, hard authorization mask, minimum-necessary exposure, escalation, CRC, and LTT. This should make the paper accessible to readers who are not already familiar with healthcare interoperability or conformal calibration.
Second, we will add a running toy example with 5-8 memory items. The example will show: the original handoff request, the receiver contract/scope token, which items are removed by the hard mask, which authorized items remain, how the greedy selector ranks/selects items, which items are escalated, and how the CRC threshold determines the operating point. We agree this would make the full framework much easier to understand.
Third, we will add a claims-to-evidence table in the main text. Each major claim will be mapped to its evidence: hard-mask safety, submodular approximation, CRC/LTT calibration, exposure-success tradeoff, label-noise robustness, distribution-shift stress, live-LLM calibration gap, adversarial red-team, Synthea-HH realism tier, and signed receipt prototype.
Fourth, we will reorganize the experimental section. Before discussing results, we will add a baseline overview explaining full-context, scope-only, authorized TF-IDF, authorized embedding retrieval, cross-encoder reranker, LLM-as-selector, and ablations. We will also report key metrics at one operating point so readers do not need to reconcile numbers across multiple tables.
Finally, we will restructure the appendix references. The revised main text will contain all essential definitions, assumptions, method steps, baseline descriptions, and headline results. Appendices will be clearly separated into core proofs/calibration, stress tests, implementation/prototype details, and additional audit/labeling analyses.