acceptodds
Published as a conference paper at NeurIPS 2026

Learning When to Collaborate: Selective Multi-Agent Medical Reasoning via Uncertainty-Aware Routing

Jiacheng Hou, Xueliang Cui, Dan Lu, Ruxin Wang

Abstract

Multi-agent systems have emerged as a promising paradigm for multimodal medical reasoning, but existing methods rely on two assumptions that hinder practical deployment: (i) always-active dense collaboration among multiple agents, and (ii) dependence on large cloud-based models that raise privacy and efficiency concerns. In this paper, we challenge both assumptions and propose SMART-Med, a fully local multi-agent method that treats collaboration as a learnable decision rather than a default behavior. Our key insight is that not every medical query requires costly multi-agent deliberation: many can be reliably solved by a single well-trained agent, while only uncertain cases benefit from expert collaboration. Based on this insight, SMART-Med introduces an uncertainty-driven routing mechanism that adaptively decides when to answer directly and when to recruit a small subset of expert agents, effectively converting dense multi-agent reasoning into selective, query-adaptive coordination. To make this routing reliable, we curate a new multimodal medical dataset MedVR-3K with high-quality reasoning traces and a difficulty hierarchy, and then fine-tune local agents using GRPO with two complementary rewards: a certainty-aware accuracy reward and a vision-language reward model for correctness and reasoning quality respectively. Experiments on four medical visual question answering benchmarks show that SMART-Med achieves competitive performance compared to existing MAS approaches while substantially reducing inference cost (reducing inference time by more than 3.8 and token usage by 72%). Moreover, after fine-tuning on MedVR-3K, SMART-Med yields an average improvement of 6.7% across Slake, PathVQA, VQA-RAD, and PMC-VQA. Our results suggest that selective collaboration can be an efficient yet effective alternative to dense collaboration and enable practical, privacy-preserving deployment of multi-agent medical AI.

Keywords:
Sydney, Main Track

Reviews

Among:
Shape:
123456this paper, Bottom 4%
Figure 1. Mean review rating of the reviewed papers at NeurIPS 2026. This paper averages 3.67 over 3 reviews, above 4% of the others.
Reviewer_FQmkOpenReview ↗
Rating
4
Clarity
3
Confidence
4
Originality
3
Quality
3
Significance
3
Read review
Summary

SMART-Med tries to address the problem of critical privacy and dense collaboration by introducing an uncertainty-driven selective collaboration mechanism and a certainty-aware accuracy reward that couples confidence with correctness, and a vision-language reward model that provides fine-grained reasoning quality feedback. Rather than requiring all agents to be involved in multi-round discussions for every query, the uncertainty-driven routing mechanism directly outputs for straightforward questions to make the whole process more efficient. They also make MedVR-3K, a reasoning-centric dataset, and fine-tune the local agent by GRPO, which is a dual reward structure: a certainty-aware accuracy reward that couples prediction confidence with correctness, and a vision-language reward model that evaluates reasoning quality.
This framework has been tested across four public benchmarks and achieves competitive performance.

Strengths and weaknesses

Strengths:

  1. Addressed the efficiency waste via selective collaboration.
  2. Local training compromises privacy.
  3. Reduce the token usage and achieve high performance.

Weakness:

  1. It's very awesome to employ a router to judge the certainty; however, I wonder if the router could accurately recognize the certainty instead of popping a hallucination into the following pipeline. In a clinical scenario, if the single model generates an incorrect diagnosis or plan, but assigns it to CERTAIN, it will be a very big safety concern. Even though in this paper, the author provides the penalty, it would be much better to have another analysis when the single model fails judgment, but it will still prevent a critical clinical safety or guarantee when facing rare diseases.
  2. Your optimal decision rule can be written as beta/(1-alpha+beta). Researchers defined these parameters, but they lack of flexibity in different situations/requirements.
Questions
  1. Could you provide any proof for the primary local agent's certainty token before and after GRPO training to empirically prove the calibration effect?
  2. Could you provide the difference inference process of one question solved by different agents/agent systems working, because it is not very clear why we have to trust that the final agentic collaboration can perform best?
Limitations

See weakness

Paper formatting concerns

No

Final justification

Thank you so much for your detailed reply. I will update my overall rating from 3 to 4.

Reviewer_BwXUOpenReview ↗
Rating
4
Clarity
3
Confidence
3
Originality
3
Quality
3
Significance
3
Read review
Summary

The paper proposes SMART-Med, a MAS for medical VQA that defers a questions to multiple agents only when the router is uncertain. The authors also introduce MedVR-3K, collected from existing MedVQA benchmarks

Strengths and weaknesses

Strengths

  • Current MAS systems, especially for medical reasoning suffer from the problem of using expensive agents for all the queries, and tackling this is useful for resource/compute limited environments, such as hospitals
  • The reduction of model calls on average is compelling

Weaknesses

  • While the paper argues that router learns when to collaborate, more qualitiative analysis is better than just calculating avg accuracy and efficiency. What % of examples are routed for collaboration and marked as certain/uncertain? How much boost in performance do the collaborated examples get as compared to using a single LLM? How much does randomized routing? since the paper is based on calibration, the paper needs many more experiments to validate their routing claims.
  • How does SMART-Med* compare to other LLMs which have been finetuned on MedVR-3k?
  • The paper lacks statistical analysis. Usually for these medical datasets, the performance per run varies quite a bit, but no error plots or p-values or significance analys si done
  • I am concerned that GPT 5.4 is used as generate the data in medvr-3k, then assign scores for reward model, and then evaluate free form answers. It’s usually not recommended to keep the model same as the judge. Can the authors do this?

I think the paper is a step in the right direction, but more experiments and analysis needs to be done before concluding how good. the uncertainty identification is. It would also be useful to get humans-in-the-loop to evaluate the responses. Right now I lean to borderline reject but I would love to discuss with the authors during discussion.

Questions

Mentioned with weaknesses.

Limitations

No, the paper should mention on failure modes of the routing along with other limitations.

Paper formatting concerns

no

Final justification

The rebuttal clarified the questions I had raised forward, and hence I am updating my score.

Reviewer_k1CgOpenReview ↗
Rating
3
Clarity
3
Confidence
4
Originality
1
Quality
3
Significance
3
Read review
Summary

The paper proposes SMART-Med, a fully-local multi-agent framework for medical VQA that treats collaboration as a learnable decision rather than a default. A router agent answers directly when confident and only recruits a small set of expert agents (with a moderator) when uncertain. To train it, the authors build MedVR-3K. and fine-tune local models with GRPO using a certainty-aware accuracy reward and a reasoning-quality reward. On four datasets, the method matches or exceeds prior MAS while cutting inference cost substantially

Strengths and weaknesses

Strengths

  • The efficiency results are the strongest and most convincing contribution: large, consistent reductions in latency, tokens, and model calls, well-supported by Fig. 4.
  • The ablation (Table 3) cleanly supports the central claim that selective routing matches dense collaboration at far lower cost.
  • The fully-local setting is well-motivated by privacy/compliance constraints, and MedVR-3K (reasoning chains + multi-dimensional quality + difficulty hierarchy) is a useful, non-trivial dataset artifact.

Weaknesses

  • The core idea (routing to more expensive computation based on uncertainty) is well established in the general domain (selective prediction with a reject option, model cascades/routing, and sparse MAS such as SMOA and MDAgents, which the paper itself cites). The medical setting and the local-only constraint are application choices; the routing mechanism itself is not new, and the paper does not articulate what is methodologically distinct from existing sparse/adaptive MAS beyond using medical data.

  • Performance gains are conflated with fine-tuning. The headline improvements come from SMART-Med, the version fine-tuned on MedVR-3K. The untuned SMART-Med is only "competitive" and loses to MOA/MedAgents on several columns (Table 1). Savings come from routing; accuracy gains come from data + RL—two separable contributions presented as one "fast and strong" story.

  • Baselines use Qwen3-VL-4B-Instruct, while SMART-Med* is fine-tuned on MedVR-3K. Comparing a fine-tuned method against untuned baselines and claiming SOTA is not a clean comparison; baselines fine-tuned on the same data are the appropriate control.

  • Circular use of GPT-5.4. The same model curates the data, trains the reasoning reward, and serves as the final reasoning-quality judge (Table 2), biasing evaluation toward its own preferences. The reported margins there are also small.

Questions

See above

Limitations

Yes in appendix E

Paper formatting concerns

No

Final justification

Thanks for the authors for providing more results. The authors acknowledge that the routing mechanism itself is not new, but argue that their contribution lies in "reformulating the role of collaboration in medical MAS" (shifting from 'how to collaborate' to 'whether to collaborate').

While I agree this is a highly valuable practical system design for resource-constrained medical settings, it is essentially an application of existing sparse/selective routing concepts to a specific domain. I still think the core algorithmic or methodological innovation remains thin. This work feels more suited for a top-tier medical informatics or applied AI venue.

I will maintain my score

Comments on the paper

1 comment
Meta-review

I have read the paper, the author response, and the follow-up discussion with the reviewers. The paper proposes SMART-Med, a fully local medical VQA framework that uses uncertainty-aware routing to decide whether a query should be answered by a single local agent or sent to multi-agent collaboration. It also introduces MedVR-3K and uses certainty-aware GRPO training to improve both reasoning quality and routing behavior.

The main strengths are the practical motivation and the efficiency results. Reducing dense collaboration, token usage, latency, and cloud dependence is valuable for medical AI settings. The paper also gives a reasonably complete system-level contribution, combining local deployment, selective collaboration, a reasoning-centric dataset, and certainty-aware training.

The potential weakness is novelty. As k1Cg noted, uncertainty-based routing and selective computation are established ideas, so the paper should avoid overstating the routing mechanism itself as a new methodological contribution. The original submission also did not fully separate gains from routing versus fine-tuning, and the use of GPT-5.4 for data construction, reward supervision, and evaluation raised concerns about evaluation bias.

The authors’ response addressed several important concerns. They added matched fine-tuning comparisons with MOA and MDAgent, independent Gemini 3 Pro judging, random-routing and always-single/always-collaborate controls, AURC analysis, and false-CERTAIN analysis before and after GRPO. BwXU found that the rebuttal answered most concerns and updated the score. FQmk raised useful follow-up concerns about false-CERTAIN errors and sensitivity to alpha/beta; the authors provided additional analyses, including a before/after GRPO false-CERTAIN comparison and beta sensitivity results. k1Cg maintained the main concern about limited methodological novelty, which I agree is valid.

Overall, I lean to accept. The novelty concern remains, but I think the practical value, strengthened experimental evidence after rebuttal, and clear efficiency benefits make the paper a useful contribution. I did not use any information beyond the written reviews, author response, and public discussion.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Related papers

Loading the map…

Discussion (0)

Sign in to comment.