- Rating
- 5
- Clarity
- 3
- Confidence
- 2
- Originality
- 3
- Quality
- 3
- Significance
- 4
Read review
Summary
This work leverages Taylor-Mode automatic differentiation to compute density functions of a any nested Archimedian Copula. This operation is fully differentiable, which is why it can be used to fit the parameters of nested Archimedian Copulas with gradient descent. Previous work relied on sampling based and non-differentiable methods to differentiate nested Archimedian Copulas, which prohibits training neural nested copulas. In their experiments the authors show that, while Taylor-Mode AD is just an approximation of the true differentiation, the model is able to recover true copula parameters from sampled data. Additionally, they show that the neural copulas, which are enabled through their approach, are better in MLE than classical approaches. A major contribution of this work is the rigorously explained Jax implementation.
Strengths and weaknesses
S1) ACOPULA is the first work that enables neural nested Copulas for high dimenensioal and partially censored data. S2) Appyling Taylor Mode AD is well motivated S3) The example from 3.1 and pseudo code helps in understanding the method.
W1) The papers is very hard to understand for readers with a pure Machine Learning background that are unfamilar with the related work that stems from the field of Statistics (such as the R packages) W2) The experimental setup could be more detailed (see Q3) W3) A more detailed introduction to the Hoefert and Pham density would make the paper more readable.
Questions
Q1) What exactly are you comparing in the experiment 5.2 ? Why does R stop after roughly ~1s of computation? . You only plot the wall-clock time. Do you also compare the accuracy?
Q2) How do the nested Archimedian copulas compare to more simpler models such as a gaussian copula ?
Q3) What exactly is the task in the MIMIC-IV/ S&P 500 experiments ?
Limitations
yes
Paper formatting concerns
no concerns
Final justification
The corrections that authors made regarding the experimental results do not change my assessment of the paper. My questions have been answered. I will keep my initial rating.
We thank the reviewer for their careful reading and feedback.
We begin with a correction to the submission, then address the reviewer's comments.
Corrections
Taylor-mode AD is exact. Taylor-mode automatic differentiation propagates truncated Taylor coefficients through exact recurrences, so the higher-order partial derivatives are exact up to floating-point rounding, in the same sense that a hand-derived formula evaluated numerically is exact. The paper reports density agreement with R's
nacLLbelow 10−14, agreement with Mathematica's symbolic derivatives up to d=60, and gradients matching central differences below 10−8.The cited neural result updates. The summary notes that the neural copulas beat the classical approaches in MLE. That was true of the submitted PDF. After submission we found an indexing bug in the censoring-mask handling that affected the correctness of the MIMIC-IV results. For details, please see the "Correction" section in the response to reviewer M4CE.
Clayton/Clayton moves from 4.949 to 7.088 and ACNet from 4.310 to 7.091, so the two differ by 0.004 nats with an interval of [-0.006, +0.014], which we cannot distinguish from zero. We therefore have updated the text in the results summary to reflect this change.
Response to Comments and Questions
W3, the Hofert–Pham density. We have added a self-contained derivation of the Hofert–Pham density on the three-variable tree as in Section 3.1 in the appendix and reference it from the "The Hofert and Pham [2013] density" paragraph.
Q1, what Section 5.2 compares and why R stops. The comparison is like-for-like: the same nested Archimedean density, the same generator families and the same nesting trees, evaluated by our implementation and by the
nacLLfunction of the Rcopulapackage on matched inputs, with the axis showing wall-clock time for one density evaluation.To further clarify, our statement that R aborts past d=40 is inaccurate: R aborts in the 900-second wall-clock cap in our own benchmark harness. We have updated our figure to now carry this wall clock time cap as an explicit annotation.
However, the R copula package does have limitations on d depending on the family:
For accuracy: We report accuracy separately in the Appendix J "Detailed R Comparison". Our densities agree with
nacLLto relative error below 10−14 on 11 of 12 nested configurations spanning d=4 to 60. The twelfth, at d=60, differs by 3.5×10−5, and Mathematica's symbolic differentiation of the CDF adjudicates it: Mathematica agrees with us to machine epsilon at every configuration we tested, whilenacLLdiverges, so the discrepancy is R's precision loss and not ours. The speed comparison therefore runs between two implementations that agree to machine precision wherever both are correct.Q2, comparison with a Gaussian copula. A Gaussian copula would likely fit the S&P data better. It carries a full correlation matrix and is a strong baseline on financial returns, though it has no tail dependence.
A Gaussian copula does not serve the goal here, for two reasons. It provides a d×d correlation matrix rather than a small hierarchy of association parameters, so it answers a different question from the one a sector model asks. More restrictively, it does not extend to the censored setting: the MIMIC-IV likelihood requires a mixed partial derivative of the joint survival function over an arbitrary subset of coordinates, which for a Gaussian copula is a high-dimensional orthant probability with no closed form. The Archimedean structure removes that obstruction, so the paper compares against tools that can express censored nested likelihoods at all.
Q3, what the task is in the MIMIC-IV and S&P 500 experiments. In both the task is estimating a hierarchical association structure. Specifically, it's not just about prediction accuracy.
For MIMIC-IV, each of 53 laboratory measurements has a time until it first becomes abnormal, right-censored at ICU discharge, and we group the labs into seven clinical panels. We estimate eight parameters: one dependence parameter within each panel and one tying the panels together, reported as Kendall's τ. Kendall's τ measures the probability that two measurements move in the same direction, so a panel with τ near 0.7 is one whose labs tend to deteriorate together. For the S&P 500 the shape is the same: 98 equities in eleven GICS sectors, twelve parameters, one within each sector and one between them.
The held-out likelihood in those tables checks the fit. It asks whether the estimated structure describes data the model has not seen. However, we do not claim that NAC models would have better prediction accuracy than other models, especially more powerful models such as vines or transformers.