Strengths
The motivation of rotationally symmetric objects admit an orbit of equally valid canonical frames, which single-output regressors cannot represent is intuitive. Thus the DORE frames rotation as distribution estimation and executes it cleanly. Representing the orbit as a band-limited density via Wigner-D coefficients, rather than committing to a parametric family or a fixed quotient, is clean and to let the model cover finite and continuous symmetry without special architectural changes.
The heat-kernel smoothing of the delta-mixture target is the nice idea. Truncating a delta mixture introduces Gibbs/ringing artifacts; convolving with the SO(3) heat kernel attenuates degree-l mass by exp(−l(l+1)σ²/2), and the authors derive a clean closed-form spectral bound (Appendix F) that they then enforce at prediction time.
The automatic symmetry-labeling pipeline is a practical contribution. Using a one-sided Chamfer invariance score with the proven equivalence to the symmetric variant (Appendix D) to halve NN-search cost, the beam search over axes, and the log-size prior for group selection are all sensible.
Major weaknesses
1. Internal numerical inconsistencies. These are the most concerning items because they affect trust in the headline numbers:
-
phone Chamfer results. Table 1 reports DORE phone Chamfer = 8.9 (×10⁻³). Table 2's ablation reports DORE on phone = 1.953 (×10⁻³) given it is the same method, same category, same units, the results are off by ~4.5×.
-
The text states DORE attains the lowest mean Chamfer "on every measured category," then two sentences later concedes phone as an exception (8.9 vs Scarvelis 2.1). The summary claim is simply false as stated.
-
Please explain this in consistency in the results.
-
Loss definition mismatch. Eq. (7) gives the objective as supervised regression only, but Eq. (51) in the appendix gives L = L_sup + α·L_equiv, while the surrounding text says the equivariance term's effect is "negligible" and is omitted. Which loss produced Table 1?
-
the need for a soft equivariance regularizer to balance the minor deviations, slightly undercuts the "equivariance by construction" framing.
2. Experimental gap in relevant baselines. The related-work section catalogs four families of SO(3) distribution methods, but the experiments compare only against CHOIR (single-pose) and Scarvelis (octahedral quotient) — neither of two seems a distributional SO(3) method. Most critically, Lee & Cho [20] already regress Wigner-D coefficients in an SO(3)-equivariant network; the central claimed delta of DORE is "orbit supervision instead of single-pose supervision." Without a comparison (even with modified version) [20] it's impossible to attribute the gains to the distributional formulation rather than to backbone/training differences. matrix Fisher [23], or a Bingham mixture [12] would also strengthen the case. This is the single largest experimental gap.
3. Generality is relative to what the pipeline supports. The abstract/intro repeatedly say "free of any restriction on the symmetry group," but the labeling candidate set (Eq. 9) is only C_n (n≤6) and D_n (2≤n≤6); "symmetry labeling currently covers cyclic and dihedral groups up to order 6, but excludes the Platonic symmetry groups T , O, and I" (acknowledged only in Limitations). The network's 286-dim output can in principle represent richer densities, but the training signal cannot generate T/O/I orbits. The framing should be modified to replicate that the representation is general and the supervision is restricted to C_n/D_n up to order 6.
4. The phone result raises a sample-efficiency concern. DORE's Accsym on phone (33.0) collapses against Scarvelis (90.8). The data-scarcity explanation (871 instances, 8× fewer than the next smallest category) is plausible, but it implies the 286-dim distributional target needs substantial data to learn. This is a real practical limitation for a method framed as general. However, doing multiple experiments with different samples size across all the categories will produce more insights both for DORE and other methods.
5. Chamfer-vs-accuracy tension on lamp goes unexplained. DORE wins lamp Chamfer decisively (11.9 vs 42.9 / 19.3) but loses lamp Accsym@ε (45.5 vs 48.3 / 47.8). Lower mean error with lower threshold-accuracy suggests a different error distribution
We thank the reviewer for the positive assessment and the pointer to AQuaMaM.
Q. Why not directly optimize the negative log-likelihood using Eq. (5)?
A truncated Wigner expansion is not guaranteed to be a valid likelihood, and with the target available in closed form the problem is regression rather than density estimation.
The expansion is not guaranteed to be non-negative. Normalization is free in our parametrization, since the integral of f^ is the l=0 coefficient, but nothing constrains a band-limited function with predicted coefficients to stay non-negative, and logf^ is undefined wherever it is not. The NLL gradient also scales as 1/f^ and grows without bound as the density approaches zero, whereas the MSE gradient stays bounded.
Regression, not density estimation. Maximum likelihood is formulated for samples drawn from an unknown distribution. Here the symmetry label gives the complete orbit and heat smoothing gives the target in closed form, so the natural objective is L2 projection onto the band. Squared coefficient error is exactly that distance by Plancherel, and the Laplace–Beltrami weights of Eq. (7) turn it into a Sobolev norm that charges high-degree error more. The loss also supervises the density everywhere, including the flat regions the peak search traverses, whereas the NLL constrains it only at the orbit points.
A positive reparametrization (an exponential family, or sum-of-squares f=∣h∣2) would make the NLL well-defined, but it gives up the linearity in the coefficients that our pipeline uses for closed-form label transport under augmentation, closed-form smoothing, and a coarse search that costs one matrix-vector product. We note this as future work.
Minor. AQuaMaM. Thank you, we will cite it. Its autoregressive factorization over unit quaternions is likelihood-valid by construction and suited to sample-based MLE, which is the regime our closed-form target lets us avoid, at the cost of sequential decoding.