- Rating
- 5
- Clarity
- 4
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 4
Read review
Summary
This work addresses the problem of uncertainty estimation for equivariant vector-valued functions, especially relevant in molecular properties. The paper introduces Equivariant Multivariate Evidential Regression (EMER), an evidential deep learning framework based on a novel parameterization of the Normal-Inverse-Wishart scale matrix. In addition, a Mahalanobis distance-based calibration metric suited for vector-valued outputs is introduced. The paper's claims are well described, the theoretical contributions are clearly presented, and the results encompass a broad class of models and datasets.
Strengths and weaknesses
Strengths
-
Principled and model-agnostic framework. The proposed evidential parameterization is clean, theoretically grounded, and backbone-agnostic: it can be attached to any equivariant model (EGNN, PaiNN, NequIP, MACE in the paper) without architectural modifications.
-
Novel and appropriate calibration metric. The Mahalanobis calibration score (MCal) is a nice contribution.
-
Extensive experiments. The paper performs extensive experiments, varying datasets, tasks, and models. Overall, this strengthens the paper.
Weaknesses
-
EMER alone does not produce well-calibrated uncertainty. Inspecting the results, EMER (without dropout) exhibits MCal and NLL values that are substantially worse than most baselines, including MC Dropout and vanilla MER. This implies that the NIW evidential prior, as implemented, leads to overconfident or poorly conditioned covariance estimates. The real source of calibration improvement is dropout regularization (EMER-D), which is applied only at training time as a regularizer. This raises a fundamental question: what is the evidential prior actually contributing beyond what a simpler regularized predictor would provide? This concern is reinforced by prior work (Tan et al., 2023 [arXiv:2305.01754]), who systematically evaluated evidential regression for neural network potentials and found it was not the preferred alternative over ensembles in any of the settings tested.
-
Missing recent and relevant baselines. Several important baselines are absent; a search led me to: (i) BLIP (Bayesian Learned Interatomic Potentials [arXiv:2508.14022]), a scalable architecture-agnostic variational Bayesian framework built on adaptive Variational Dropout, which integrates with equivariant message-passing architectures and has been shown to outperform ensembles while providing calibrated uncertainty with minimal overhead. (ii) The methods evaluated in Tan et al., 2023 [arXiv:2305.01754], which are also relevant to the claim of state-of-the-art accuracy and calibration. The paper represents a de facto standard approach to UQ in MLIP, and the same tests should be performed to claim SOTA,
-
Ensemble performance is not clearly surpassed. Inspecting the results, it is clear that Ensembles achieve competitive performance on several molecules. The claim of state-of-the-art accuracy should be qualified, especially given that no standard deviations across seeds are reported. The paper acknowledges results are averaged over three seeds, but without confidence intervals, it is impossible to assess whether differences between methods are statistically significant.
-
Calibration metrics are not validated against established standards. The paper introduces MCal as a new metric and primarily evaluates methods through it, but does not verify whether MCal rankings agree with the correlation-based metrics proposed by Tan et al., which relate predicted uncertainty directly to empirical model error.
Questions
-
Adding the backbone name to each table caption would make the tables self-contained and easier to reference. Can you do it?
-
The paper references PaiNN but misses the citation in the main text at line 312. This should be corrected.
-
Why does MACE underperform PaiNN and NequIP in Table 2? MACE is generally considered the strongest backbone among those tested, so this is surprising. Is MACE used here as pretrained and fine-tuned, or trained from scratch?
-
Can you add to Figure 2: (1) a random acquisition baseline (querying random samples instead of using uncertainty), which is the standard sanity check in active learning, and (2) a fully supervised upper bound trained on all available data (or a random sample of 200 data points matching the total budget). Without these, it is difficult to assess whether the observed MAE differences across UE methods are meaningful or whether any informed acquisition strategy meaningfully outperforms random selection.
Limitations
Yes.
Paper formatting concerns
No issues found.
Final justification
I recommend accepting the paper. The proposed method is novel, and its evidential parameterization is clean, theoretically grounded, and backbone-agnostic. Furthermore, the authors introduce a new calibration metric that could be highly useful to practitioners.
During the rebuttal, the authors addressed most of my comments by providing additional experiments and revising unclear phrasing in the paper. Although dropout remains necessary for the model to train properly, this is a standard technique for preventing overfitting in deep learning models, including transformers. In my view, this issue is not sufficient grounds for rejecting the paper.
Overall, I am inclined to support acceptance, as principled, model-agnostic uncertainty quantification is currently lacking for machine-learning force fields. This work could help advance the state of the field. Following the rebuttal, I increased my score from 4 to 5.
We thank the reviewer for the constructive reading. We address the main clarification requests below and state where the manuscript will be revised when revision is permitted.
W1/R1. Novelty framing.
We agree that the covariance transformation law itself is not the novelty. Once vector uncertainty is posed correctly, the tensor transformation rule is forced. When manuscript revision is permitted, we will combine the current contribution statements on PDF pp.2-3, lines 77-80 into one clearer contribution: we propose a novel equivariant covariance parameterization for vector uncertainty that satisfies the required equivariance transformation law while remaining positive-definite and practically identifiable.
Q1/RQ1. Interpreting MCal relative to RCal/NLL.
They answer different questions. MCal evaluates the full vector uncertainty ellipsoid through the Mahalanobis distance, so its meaning is invariant to the coordinate frame. RCal and per-axis NLL evaluate scalar marginals; they are useful, but frame-dependent.
The two can disagree when a covariance has roughly the right total scale but the wrong directional shape. This is exactly the failure mode of a non-equivariant covariance. On naphthalene RotOOD in the submitted Table 1:
Both metrics favor EMER-D on this molecule, but they diagnose different aspects of the improvement: MCal improves from 0.201 to 0.147, while Max RCal improves much more sharply from 0.706 to 0.156. Across all 7 MD17-RotOOD molecules in the submitted Table 1, EMER-D improves Max RCal over MER-D, showing that the rotation-sensitive marginal metric exposes the covariance-orientation failure most clearly.
When manuscript revision is permitted, we will add this guidance in Appendix "Evaluation Metrics" at PDF p.19 line 705: MCal should be the primary coordinate-independent vector calibration metric, but it should be reported with Max RCal/NLL to verify that the uncertainty ellipsoid is not only correctly scaled but also correctly oriented.
Q2/RQ2. Equivariance versus dropout regularization.
Dropout is a shared training-time regularizer in all "-D" variants; it is not MC-dropout at inference. Thus the matched MER-D vs EMER-D comparison isolates the equivariant covariance. In the submitted Table 1, at fixed dropout EMER-D reduces Max RCal from 0.706 to 0.156 on naphthalene, 0.617 to 0.120 on salicylic acid, 0.811 to 0.283 on uracil, and 0.450 to 0.182 on toluene. These are the anisotropic/ring systems where the covariance direction matters most.
The key same-dropout evidence from submitted Table 1 is shown below (MD17-RotOOD; lower is better):
This is the cleanest comparison for the reviewer's question because both models use the same dropout regularization, seeds, splits, backbone, and budget. The remaining difference is whether the covariance is equivariant.
Q3/RQ3. Scope of RotOOD.
RotOOD is a controlled diagnostic, not a claim that real deployment consists of one fixed rotation. Its purpose is to hold the molecule and force field fixed while changing only the coordinate frame. This exposes a specific issue: a non-equivariant uncertainty head can appear calibrated on aligned train/test splits because both share the same orientation bias, yet fail when queried in another frame. The new part here is the uncertainty-calibration consequence of dataset alignment, not the existence of alignment bias itself.
For how often this can matter, we will be concrete rather than expansive. The recent ICLR 2026 paper "Take Note: Your Molecular Dataset Is Probably Aligned" documents that common molecular datasets can have orientation bias and that models can exploit it. Our setting is narrower but consistent with this concern: in our MD17 study, two molecules, Naphthalene and Uracil, already exhibit predominantly planar force-label distributions, as noted in the current manuscript. Thus RotOOD is not meant to simulate every deployment distribution, but it targets a real dataset property that can affect vector uncertainty evaluation.
For deployment, the relevance is that MD trajectories, generated conformers, screening poses, and active-learning candidates are not guaranteed to be presented in the training frame. In those settings an uncertainty threshold should not depend on arbitrary global orientation.
When manuscript revision is permitted, we will revise the RotOOD construction paragraph in Experiments at PDF p.8, lines 289-290 as follows: such orientation-bias effects have been specifically discussed in the recent work [Ref "Take Note: Your Molecular Dataset Is Probably Aligned"]; they also occur in the MD17 dataset used here, where Naphthalene and Uracil exhibit predominantly planar force-label distributions.
Q4/RQ4. Role of equivariant covariance beyond the rotated diagnostic.
The role is not only "better under a synthetic rotation." Once the target is a vector, the full predictive distribution should transform consistently: the mean rotates as a vector and the covariance rotates as a rank-2 tensor. Otherwise the same molecular state can receive different confidence regions, likelihoods, or acquisition priorities solely because the Cartesian axes changed. RotOOD is therefore a controlled test of a probabilistic consistency requirement, not the only motivation for equivariance.
This principle is also emerging in recent geometric-UQ work: the ICML 2026 paper "Equivariant Covariance Tensors: Guaranteed SPD Uncertainty for Tensor-Valued Geometric Learning" similarly treats symmetry-preserving covariance and positive-definiteness as requirements for uncertainty on geometric outputs, though for tensor-valued rather than vector-valued targets.
Our contribution is to make this requirement trainable with an anisotropic SPD covariance. In
Σ = exp(α)I + FF^T, the scalar term provides a positive isotropic floor, whileFF^Tprovides geometry-dependent directional uncertainty.Together, these clarifications show that RotOOD is a controlled diagnostic for a real probabilistic consistency issue: vector uncertainty should rotate with the vector target, and our parameterization makes this requirement trainable and stable.