- Rating
- 5
- Clarity
- 2
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
Summary
- This paper study the problem of adding noise during the PF-ODE sampling process. Adding stronger noise leads to better diversity but worse quality. This paper aims to find a principled way to describe this phenomena.
- This paper propose that this trade-off is governed by two quantity of noise: asymptotic covariance and Poisson solution norm.
- Based on their theoretical analysis, this paper propose FDS, a new intermediate point between SDE and PF-ODE which balance diversity and sample quality for low NFEs.
Strengths and weaknesses
Strength
- This paper provide a principled approach studying the trade-off between diversity and sample quality during noise injection of PF-ODE trajectory.
- The proposed FDS works well for both low NFE and high NFE region.
Weakness
- This paper need a section defining notations. For example, in line 102 looks like a Markov kernel, in line 106 looks like Brownian noise. The readers have to guess the meaning of symbols during the reading process, which ruins clarity of this paper.
- In Fig 2, why is the left two figures show relative reduction while right two figures show absolute value? Does the FID of proposed approach goes monotonously down as NFE increase?
Questions
Questions
- I think the method proposed in this paper is theoretically sound and empirically works well. This paper is a typical excellent paper in NIPS. I recommend a clear acceptance.
Limitations
yes
Paper formatting concerns
no
Final justification
Thanks for the rebuttal. I keep my rating and recommend to accept this paper.
We thank the reviewer for recognizing the method as theoretically sound and empirically effective, and for the concrete clarity suggestions.
We agree. We will add the following notation block before the theoretical development and repeat the local definitions before Eq. (10) and Theorem 2. Here m is the driver dimension and d is the sampler-state dimension.
This gives each symbol its role and dimension before it is used, rather than requiring readers to infer them from the theorems.
The panels intentionally use different reporting forms: FID is shown relative to ODE, while Recall and DINOv2-FD remain in native units. Percentage FID reduction is comparable across DiT and EDM2 despite their different absolute scales, and the zero line exposes wins and losses directly. Native units preserve the companion metrics' actual operating points.
The full evaluation spans two backbones, up to four methods, ten NFE budgets, and companion metrics. To keep the four-panel main figure readable within the page limit, we use it as a compact summary, while the submitted appendix tables report every absolute FID with mean and standard deviation. We agree that the current caption does not make this division clear. We will label each quantity explicitly, add a direct appendix cross-reference, and include absolute FID companion curves in the appendix so both views are directly available.
No. FDS FID trends strongly downward but is not strictly monotone at every adjacent budget. DiT FDS falls from 16.15 at NFE=5 to 3.46 at NFE=20, with one small local reversal from 3.90 at NFE=9 to 4.00 at NFE=10. EDM2 FDS decreases monotonically from 13.88 to 1.80 over NFE=5--20. Relative gain can vary because the ODE denominator also improves. We will state this directly rather than imply strict monotonicity.