- Rating
- 5
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The main goal of the paper is to address the spectral bias in diffusion models. This phenomenon is the tendency of diffusion models to resolve low-frequency, global structure early in sampling and to fill in high-frequency detail later. The authors argue that standard SDE samplers ignore this by injecting uniform white noise at every step, spending a fixed noise budget on bands that are already resolved. To address it, they propose Colored Noise Sampling (CNS), a training-free, plug-and-play replacement for the stochastic sampler that shapes the injected noise in each frequency band, shifting energy toward unresolved bands while keeping the total injected energy fixed. The allocation is driven by a progression matrix that tracks how resolved each band is at each step. They report FID improvements over ODE and SDE baselines on ImageNet-256 (SiT, JiT) and apply the method to text-to-image generation with FLUX.
Strengths and weaknesses
Strengths
- The proposed method is training-free and works in a plug-and-play manner. This is advantageous compared to alternative methods that involve modifying the pre-trained diffusion model.
- The evaluation is extensive. The method is tested across latent (SiT), pixel (JiT), and text-to-image (FLUX) models, across solver orders (Euler, Heun, SRK), under both guided and unguided settings, and on several datasets.
- The authors include ablations for the design choices (variance constraint, temporal permutations, ...)
Weaknesses
- The authors have not motivated the problem well. They state "spectral bias" and cite [60,20], but those papers only describe the coarse-to-fine ordering, and after reading them, I do not believe they discuss “spectral bias” as a problem. Does spectral bias here just mean diffusion models generate low frequencies early and high frequencies late? If so, what is wrong with that? What the authors actually fix is the gap between the generated and real image spectra (Sec. 3.4, Fig. 4). I think this is a separate issue and it is not obvious if it is directly connected to the bias. Since this is the core of the paper, I expect a clear argument for why spectral bias is a critical issue, not just citations about the topic.
- What is the main takeaway from Figure 1? The caption says CNS "dynamically reallocates injected stochastic energy to unresolved frequency bands," and the text calls it "a visualization of our approach," but the figure only shows output samples from the three methods, which look almost identical. It does not show the approach, the colored noise, the energy reallocation, or the frequency bands. If anything, three near-identical images suggest the method changes very little. I expect Figure 1 to either visualize the approach or make its effect clearly visible (for example, zoomed crops where the high-frequency detail differs), not just show samples that look the same.
- In several settings, the standard SDE is worse than the deterministic ODE (Tables 1, 4, 5). I would expect to see a properly tuned stochastic sampler to at least match the deterministic one. Are the SDE baselines properly set? It would be good to see a comparison against the strongest solver.
Minor comments
- The first sentence of the abstract does not sound grammatically correct.
- In Table 2, the authors write out “Precision” and “Recall” fully, while in Table 1, they are abbreviated. Since there is enough space, I suggest that authors write them fully in all tables and maintain consistency.
Questions
Please see my weaknesses section, and here are some related questions.
-
The paper attributes the spectral gap to score error rather than to white noise, ignoring the bias. Could the authors clarify what the actual problem is? Is it the spectral bias itself or the score-error-induced spectral gap?
-
Are all the baselines tuned fairly? Any reason Score SDE is performing poorly in several places?
Limitations
Yes
Paper formatting concerns
N/A
Final justification
Overall, the method is technically solid and well supported by the experiments and ablations. The rebuttal also clarified that the main problem is the score-error-induced spectral gap, addressing my primary concern. I therefore recommend acceptance.
Meta-review
All four reviewers give an initial rating of borderline accept, finding the core idea of exploiting spectral bias in SDE sampling interesting. The concerns are shared and should be addressed in the rebuttal. All four reviewers question the "plug-and-play" claim, since the γ matrix requires an offline calibration stage and several hyperparameters are tuned per architecture. Three reviewers also ask for comparisons against the inference-time spectral methods cited in the related work, and for evidence that gains in the 2–4% range exceed seed-to-seed variance. One reviewer additionally asks for a clearer articulation of why spectral bias is itself a problem, as distinct from the spectral gap the method actually addresses.